    Elevated gamma glutamyl transferase levels are associated with the location of acute pulmonary embolism. Cross-sectional evaluation in hospital setting

    Full text link
    ABSTRACT CONTEXT AND OBJECTIVE: The location of embolism is associated with clinical findings and disease severity in cases of acute pulmonary embolism. The level of gamma-glutamyl transferase increases under oxidative stress-related conditions. In this study, we investigated whether gamma-glutamyl transferase levels could predict the location of pulmonary embolism. DESIGN AND SETTING: Hospital-based cross-sectional study at Cumhuriyet University, Sivas, Turkey. METHODS : 120 patients who were diagnosed with acute pulmonary embolism through computed tomography-assisted pulmonary angiography were evaluated. They were divided into two main groups (proximally and distally located), and subsequently into subgroups according to thrombus localization as follows: first group (thrombus in main pulmonary artery; n = 9); second group (thrombus in main pulmonary artery branches; n = 71); third group (thrombus in pulmonary artery segmental branches; n = 34); and fourth group (thrombus in pulmonary artery subsegmental branches; n = 8). RESULTS : Gamma-glutamyl transferase levels on admission, heart rate, oxygen saturation, right ventricular dilatation/hypokinesia, pulmonary artery systolic pressure and cardiopulmonary resuscitation requirement showed prognostic significance in univariate analysis. The multivariate logistic regression model showed that gamma-glutamyl transferase level on admission (odds ratio, OR = 1.044; 95% confidence interval, CI: 1.011-1.079; P = 0.009) and pulmonary artery systolic pressure (OR = 1.063; 95% CI: 1.005-1.124; P = 0.033) remained independently associated with proximally localized thrombus in pulmonary artery. CONCLUSIONS : The findings revealed a significant association between increased existing embolism load in the pulmonary artery and increased serum gamma-glutamyl transferase levels

    Intraoperative left atrium inversion after implantation of HeartMate III ventricular assist device

    No full text
    <p>We report here a case of left atrium inversion after implanting HeartMate III LVAD, which is known to be the first in literature. LVAD can be functional only if there is adequate inflow to the device. Parameters and filling of left ventricle can be assessed by TEE. In our case, initial examination with TEE showed thrombus like images. HeartMate III has a reliable algorithm that automatically reduces pump speed if ‘suction effect’ is detected. HeartMate III demonstrates clean flow properties and good surface wash. Despite these positive features of the HeartMate III, left atrium inversion can still be seen with it, so users should be alert in this regard.</p
    corecore