1,392 research outputs found

    Blockchain technologies in healthcare institutions : focus on security and effective cooperation with the government

    Get PDF
    Purpose: This article considers the relevance of healthcare modernization processes in Russia in terms of marketing activities activation, public-private partnerships intensification. Design/Methodology/Approach: The problem of ensuring security when government and healthcare institutions interact by means of blockchain technologies is under-explored and requires further research and investigation. Therefore, methods of induction, deduction, problem, system and logical analysis along with the economic process and system modelling method combined with the formalization method are used in this article. Findings: A mechanism for effective ensuring the safety of interaction between the government and healthcare institutions using blockchain technologies in the course of conducting financial flows and operational information exchange in modern Russia is proposed. Practical Implications: The proposed mechanism for effective ensuring of security in terms of interaction between the government and the healthcare institution by means of blockchain technologies in modern Russia effectively ensures the security of interaction between the government and healthcare institutions . Originality/Value: Authors’ findings could be introduced into the healthcare industry.peer-reviewe

    Multicriterion optimization of processing of mill trunnion based on hierarchy analysis method

    Get PDF
    The article presents the choice of optimal method of treatment when restoring of mill trunnion based on hierarchy analysis method. The criterion for selecting optimal cutting conditions is synthesized and their relationship with processing parameters is described. Many alternatives for solving a multicriterion optimization problem are constructed, methods of processing with variable cutting conditions are propose

    A New World Average Value for the Neutron Lifetime

    Full text link
    The analysis of the data on measurements of the neutron lifetime is presented. A new most accurate result of the measurement of neutron lifetime [Phys. Lett. B 605 (2005) 72] 878.5 +/- 0.8 s differs from the world average value [Phys. Lett. B 667 (2008) 1] 885.7 +/- 0.8 s by 6.5 standard deviations. In this connection the analysis and Monte Carlo simulation of experiments [Phys. Lett. B 483 (2000) 15] and [Phys. Rev. Lett. 63 (1989) 593] is carried out. Systematic errors of about -6 s are found in each of the experiments. The summary table for the neutron lifetime measurements after corrections and additions is given. A new world average value for the neutron lifetime 879.9 +/- 0.9 s is presented.Comment: 27 pages, 13 figures; Fig.13 update

    Mathematical description of stress-strain state of trunnion of ball mill taking into account temperature field

    Get PDF
    The article considers the trunnion of a ball mill in the framework of theory of elasticity, which is subjected to an uneven thermal impact due to the heating of the load. Equations describing the radial displacement of the point inside the trunnion of a ball mill are obtained. The equations describing the movement of trunnion points of the ball mill are derive

    Визначення L-цистину в пігулках з використанням методу хемілюмінесценції

    Get PDF
    Aim. To develop the method for the quantitative determination of L-cystine in sublingual tablets Elthacin® using the method of chemiluminescence inhibition in the H2L (luminol) – Н2О2 – Нb (hemoglobin) system.Materials and methods. The study objects were the pure substance of L-cystine of pharmaceutical grade and sublingual tablets Elthacin® produced by the Medical Scientific-Production Complex “Biotics Ltd” (Russia) containing 70 mg of glycine, L-glutaminic acid and L-cystine in their composition. The intensity of chemiluminescence was measured on the device with a FEU-84-A photoelectric multiplier using an IMT-0.5 measuring instrument of low currents and a quick-acting automatic potentiometer.Results and discussion. The method of the L-cystine quantitative determination in tablets based on the inhibition of chemiluminescence in the H2L – H2O2 – Hb system has been developed. The calibration graph was linear over the concentration range from 7 to 70 μg · mL–1. No interferences were observed in the presence of common components of the tablets, such as glycine and L-glutaminic acid. RSD = ± 2.35 %, (δ = + 1.13 %), LOD (3S) = 4 μg · mL–1, LOQ (10S) = 13 μg · mL–1 for the sublingual tablets Elthacin®.Conclusions. The method proposed is promising for further research on the subject of its application for the determination of L-cystine in drugs.Цель. Целью данной работи была разработка методики количественного определения L-цистина в сублингвальных таблетках Элтацин® по эффекту ингибирования хемилюминесценции системы H2L (люминол) – Н2О2 – Нb (гемоглобин).Материалы и методы. Объектом исследования были сублингвальные таблетки Элтацин® производства ООО Медицинский научно-производственный комплекс «Биотики» (Россия) состава: глицина, кислоты L-глутаминовой и L-цистина по 70 мг и субстанция L-цистина. Интенсивность хемилюминесценции измеряли на установке с фотоэлектронным умножителем ФЭУ-84-А, измерителем малых токов ИМТ-0,5 и быстродействующим потенциометром-самописцем.Результаты и их обсуждение. Разработана методика и показана возможность количественного определения L-цистина в сублингвальных таблетках Элтацин® по 70 мг методом ингибирования хемилюминесценции системы H2L – H2O2 – Hb. Калибровочный график линеен в диапазоне концентраций от 7 до 70 мкг · мл–1. Присутствие глицина и L-глутаминовой кислоты не оказывало никакого влияния на интенсивность хемилюминесценции. RSD = ± 2,35 %, (δ = + 1,13 %), LOD (3S) = 4 мкг · мл–1, LOQ (10S) = 13 мкг · мл–1 для сублингвальных таблеток Элтацин®.Выводы. Предложенный метод может быть использован для определения L-цистина в препаратах.Мета. Метою даної роботи було розроблення методики кількісного визначення L-цистину в сублінгвальних таблетках Елтацин® за ефектом інгібування хемілюмінесценції системи H2L (люмінол) – Н2О2 – Нb (гемоглобін).Матеріали та методи. Об’єктом дослідження були пігулки під’язикові Елтацин® виробництва ТОВ Медичний науково-виробничий комплекс «Биотики» (Росія) складу: гліцину, кислоти L-глутамінової та L-цистину по 70 мг та субстанція L-цистину. Інтенсивність хемілюмінесценції вимірювали на установці з фотоелектронним помножувачем ФЭУ-84-А, вимірювачем малих струмів ИМТ-0,5 і швидкодіючим потенціометром-самописцем.Результати та їх обговорення. Опрацьована методика та показана можливість кількісного визначення L-цистину в пігулках під’язикових Елтацин® по 70 мг методом інгібування хемілюмінесценції системи H2L – H2O2 – Hb. Калібрувальний графік лінійний в діапазоні концентрацій від 7 до 70 мкг · мл–1. Присутність гліцину та L-глутамінової кислоти не чинила жодного впливу на інтенсивність хемілюмінесценції. RSD = ± 2,35 %, (δ = + 1,13 %), LOD (3S) = 4 мкг · мл–1, LOQ (10S) = 13 мкг · мл–1 для сублінгвальних таблеток Елтацин®.Висновки. Запропонований метод може бути використаний для визначення L-цистину у лікарських препаратах
    corecore