10 research outputs found
Surgical Treatment of Distal Radial Fractures with External Fixation Versus Volar Locking Plate A Multicenter Randomized Controlled Trial
Background:
The use of volar locking plate fixation (VLP) for unstable extra-articular distal radial fractures has increased in the last decades. External fixation (EF) is less frequently used. This change of surgical approach has only to some extent been evidence-based.
Methods:
In this multicenter, randomized controlled trial, we compared VLP and EF in patients between 18 and 70 years of age who had a displaced extra-articular distal radial fracture (OTA/AO type A3). The patients were examined at 6 weeks, 3 months, and 1 year postoperatively. The primary outcome measure was the Patient-Rated Wrist/Hand Evaluation score (PRWHE). Secondary outcomes were the shortened version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), pain score on a visual analog scale (VAS), and radiographic measurements. Range of motion, grip strength, finger stiffness, complications, and reoperations were also recorded.
Results:
One hundred and fifty-six patients were included. One hundred and forty-two (91%)—127 women (89%) and 15 men (11%)—completed 1 year of follow-up. Sixty-nine patients were treated with VLP and 73, with EF. The mean age was 56 years. At 6 weeks, the median PRWHE score was significantly higher in the EF group (44) compared with the VLP group (27) (p < 0.001). At 3 months and 1 year, the difference between groups was not significant. The median QuickDASH score was 27 in the VLP group and 43 in the EF group at 6 weeks (p < 0.001), and a significant difference persisted at 3 months (p = 0.023). The VLP group had superior results in terms pain during activity, wrist extension, and ulnar and radial deviation at 1 year, whereas the number of major complications was similar in the 2 groups.
Conclusions:
Patients treated with VLP had earlier recovery of function compared with patients treated with EF. One year postoperatively, we found no significant functional difference.publishedVersio
Different osteosyntheses for Colles' fracture: A mechanical study in 42 cadaver bones
Background and purpose In recent years several different plate designs for internal fixation of fractures of the distal radius have been developed. However, few biomechanical studies have been performed to compare these new implants. The purpose of this study was to compare the mechanical properties of 5 different commercially available plates (3 volar and 2 dorsal) with standard K-wire fixation using a distal radial cadaver model
Long-term survival of 2997 finger metacarpophalanageal joint arthroplasties from the Norwegian Arthroplasty Register
We present the long-time survival of 2997 primary metacarpophalangeal (MCP) joint implants from the Norwegian Arthroplasty Register from 1994 to 2019. Six different implants were compared in terms of survival and risk of revision. The majority of implants were inserted in patients diagnosed with inflammatory diseases and in women. The overall survival was found to be 94%, 89%, 85% and 84% after 5, 10, 15 and 20 years. The most prevalent reason for revision was a fractured prosthetic component, and the second was pain. Implants inserted in the right hand and in younger patients had a higher risk for revision. Sex, type of implant, finger treated, one- or two-component prosthesis, and inflammatory or non-inflammatory conditions did not influence the survival. The frequency of MCP joint implantations decreased during the observation period. Our data show satisfactory long-term survival of the MCP implants, with no difference found between implant types or concepts.publishedVersio
Surgical Treatment of Distal Radial Fractures with External Fixation Versus Volar Locking Plate A Multicenter Randomized Controlled Trial
Background:
The use of volar locking plate fixation (VLP) for unstable extra-articular distal radial fractures has increased in the last decades. External fixation (EF) is less frequently used. This change of surgical approach has only to some extent been evidence-based.
Methods:
In this multicenter, randomized controlled trial, we compared VLP and EF in patients between 18 and 70 years of age who had a displaced extra-articular distal radial fracture (OTA/AO type A3). The patients were examined at 6 weeks, 3 months, and 1 year postoperatively. The primary outcome measure was the Patient-Rated Wrist/Hand Evaluation score (PRWHE). Secondary outcomes were the shortened version of the Disabilities of the Arm, Shoulder and Hand (QuickDASH), pain score on a visual analog scale (VAS), and radiographic measurements. Range of motion, grip strength, finger stiffness, complications, and reoperations were also recorded.
Results:
One hundred and fifty-six patients were included. One hundred and forty-two (91%)—127 women (89%) and 15 men (11%)—completed 1 year of follow-up. Sixty-nine patients were treated with VLP and 73, with EF. The mean age was 56 years. At 6 weeks, the median PRWHE score was significantly higher in the EF group (44) compared with the VLP group (27) (p < 0.001). At 3 months and 1 year, the difference between groups was not significant. The median QuickDASH score was 27 in the VLP group and 43 in the EF group at 6 weeks (p < 0.001), and a significant difference persisted at 3 months (p = 0.023). The VLP group had superior results in terms pain during activity, wrist extension, and ulnar and radial deviation at 1 year, whereas the number of major complications was similar in the 2 groups.
Conclusions:
Patients treated with VLP had earlier recovery of function compared with patients treated with EF. One year postoperatively, we found no significant functional difference
Females report higher postoperative pain scores than males after ankle surgery
Objectives: The majority of patients experience moderate-to-intense pain following ankle surgery. Early, adequate treatment of postoperative pain is desirable for optimal pain relief, which in turn may facilitate optimal pulmonary function, normal respiration pattern, rehabilitation and prevention of a chronic pain condition. In this retrospective study, we aimed to identify possible predictors of moderate-to-intense postoperative pain while in the Post Anaesthesia Care Unit (PACU) in patients operated for ankle fractures. Materials and methods: Social demographics and clinical characteristics from admission throughout the stay in the PACU were collected from the hospital patient record system in retrospect. Pain was assessed using a Visual Analogue Scale (VAS) or a verbal Numeric Rating Scale (vNRS). A VAS/vNRS score 4–6 was classified as moderate and 7–10 as intense pain. Other factors which were investigated were time from ankle fracture to surgery, anaesthetic procedure, pre-, per- and postoperative medical treatment, radiological classification, complexity of fracture, operative technique, and time using tourniquet procedure. Results: Data from 336 patients who underwent surgery to repair an ankle fracture between January 2009 and December 2010 were analysed. None of the following variables had a statistically significant effect on pain; age, weight, smoking, timeframe from fracture to operation, type of anaesthesia, opioids given peroperatively, complexity of the fracture, operation technique or tourniquet inflation procedure. Female sex predicted moderate-to-intense postoperative pain in the PACU with odds ratio 2.31 (95% confidence interval 1.39–3.86), P = 0.001. As far as we know, this is the first study to show a sex difference in reporting pain in the first hours after surgery for ankle fracture. Conclusion: Female patients operated for ankle fracture report higher pain-intensity-score than male patients while in the PACU. Implications: Our findings suggest that treatment strategies to prevent high peaks of pain should particularly target women operated for an ankle fracture
Current national hand surgery registries worldwide
Registries in orthopaedic surgery were introduced in the late 1960s by the Mayo Clinic followed on a national level in Sweden in 1975, Finland in 1980 and Norway in 1987. Registries initially concentrated on knee and hip arthroplasties, which have been expanded to many other surgeries and favour epidemiological research and medical device surveillance
Reconfigurable electrostatically doped 2.5-gate planar field-effect transistors for dopant-free CMOS
In this paper, we demonstrate by extending TCAD simulations based on experimental data of fabricated electrostatically doped, reconfigurable planar double-gate field-effect transistors, the improved characteristics of a triple gate device design. The technological cornerstones for this general-purpose FET comprise mid-gap Schottky S/D junctions on a silicon-on-insulator substrate. The transistor type, i.e. n-type or p-type, is interchangeable during operation by applying a control-gate voltage which significantly increases the flexibility and versatility in the design of integrated circuits