412 research outputs found

    Advances in standardization of laboratory measurement procedures: implications for measuring biomarkers of folate and vitamin B-12 status in NHANES1234

    Get PDF
    Population studies such as NHANES analyze large numbers of laboratory measurements and are often performed in different laboratories using different measurement procedures and over an extended period of time. Correct clinical and epidemiologic interpretations of the results depend on the accuracy of those measurements. Unfortunately, considerable variability has been observed among assays for folate, vitamin B-12, and related biomarkers. In the past few decades, the science of metrology has advanced considerably, with the development of improved primary reference measurement procedures and high-level reference materials, which can serve as the basis for accurate measurement. A rigorous approach has been established for making field methods traceable to the highest-level reference measurement procedures and reference materials. This article reviews some basic principles of metrology and describes their recent application to measurements of folate and vitamin B-12

    Vitamin D Levels in Relation to Low Back Pain During Adolescence

    Get PDF
    This study aimed to investigate the association between 25-hydroxyvitamin D (25(OH)D) level and low back pain (LBP) among adolescents while adjusting for potential confounders pertinent to this age group including the weight of school bags, BMI and physical activity. A cross-sectional study was conducted on 760 randomly selected adolescents in middle schools. Data on LBP and the risk factors for LBP were collected from parents by a self-administered questionnaire and from adolescents by face-to-face interview. Blood samples were tested in an accredited laboratory; and 25(OH)D was measured using liquid chromatography-tandem MS. The lifetime prevalence and the 6-month prevalence of LBP were 32.28 (95 % CI 28.97, 35.73) % and 21.26 (95 % CI 18.40, 24.33) %, respectively. There was no difference in the geometric mean of 25(OH)D between those with and without LBP in the past 6 months (28.50 nmol/l and 30.82 nmol/l, respectively; P = 0.122). There was no association between 25(OH)D and LBP in the univariable or multivariable analysis whether 25(OH)D fitted as a continuous or as a categorical variable. We found no association between vitamin D level and LBP in adolescents in an area with high prevalence of vitamin D deficiency. Although it is important to have sufficient vitamin D levels during adolescence for several other health benefits, we concluded that vitamin D is not a major determinant for LBP among adolescents in our setting

    Options for basing Dietary Reference Intakes (DRIs) on chronic disease endpoints: report from a joint US-/Canadian-sponsored working group.

    Get PDF
    Dietary Reference Intakes (DRIs) are used in Canada and the United States in planning and assessing diets of apparently healthy individuals and population groups. The approaches used to establish DRIs on the basis of classical nutrient deficiencies and/or toxicities have worked well. However, it has proved to be more challenging to base DRI values on chronic disease endpoints; deviations from the traditional framework were often required, and in some cases, DRI values were not established for intakes that affected chronic disease outcomes despite evidence that supported a relation. The increasing proportions of elderly citizens, the growing prevalence of chronic diseases, and the persistently high prevalence of overweight and obesity, which predispose to chronic disease, highlight the importance of understanding the impact of nutrition on chronic disease prevention and control. A multidisciplinary working group sponsored by the Canadian and US government DRI steering committees met from November 2014 to April 2016 to identify options for addressing key scientific challenges encountered in the use of chronic disease endpoints to establish reference values. The working group focused on 3 key questions: 1) What are the important evidentiary challenges for selecting and using chronic disease endpoints in future DRI reviews, 2) what intake-response models can future DRI committees consider when using chronic disease endpoints, and 3) what are the arguments for and against continuing to include chronic disease endpoints in future DRI reviews? This report outlines the range of options identified by the working group for answering these key questions, as well as the strengths and weaknesses of each option

    Modeling a methylmalonic acid–derived change point for serum vitamin B-12 for adults in NHANES

    Get PDF
    Background: No consensus exists about which cutoff point should be applied for serum vitamin B-12 (SB-12) concentrations to define vitamin B-12 status in population-based research. Objective: The study’s aim was to identify whether a change point exists at which the relation between plasma methylmalonic acid (MMA) and SB-12 changes slope to differentiate between inadequate and adequate vitamin B-12 status by using various statistical models. Design:We used data on adults ($19 y; n = 12,683) from NHANES 1999–2004—a nationally representative, cross-sectional survey. We evaluated 6 piece-wise polynomial and exponential decay models that used different control levels for known covariates. Results: The MMA-defined change point for SB-12 varied depending on the statistical model used. A linear-splines model was determined to best fit the data, as determined by the approximate permutation test; 3 slopes relating SB-12 and MMA and resulting in 2 change points and 3 subgroups were shown. The first group (SB-12 ,126 pmol/L) was small and had the highest MMA concentration (median: 281 nmol/L; 95% CI: 245, 366 nmol/L; n = 157, 1.2%); many in this group could be considered at high risk of severe deficiency because combined abnormalities of MMA and homocysteine were very frequent and the concentrations themselves were significantly higher. The highest SB-12 group (SB-12 .287 pmol/ L; n = 8569, 67.6%) likely had adequate vitamin B-12 status (median MMA: 120 nmol/L; 95% CI: 119, 125 nmol/L). The vitamin B-12 status of the sizable intermediate group (n = 3957, 33%) was difficult to interpret. Conclusions: The 3 distinct slopes for the relation between SB-12 and MMA challenges the conventional use of one cutoff point for classifying vitamin B-12 status. In epidemiologic research, the use of one cutoff point would fail to separate the small, severely deficient group from the intermediate group that has neither normal nor clearly deficient vitamin B-12 concentrations (ie, unknown vitamin B-12 status). This intermediate group requires further characterization

    Biomarkers of folate status in NHANES: a roundtable summary123456

    Get PDF
    A roundtable to discuss the measurement of folate status biomarkers in NHANES took place in July 2010. NHANES has measured serum folate since 1974 and red blood cell (RBC) folate since 1978 with the use of several different measurement procedures. Data on serum 5-methyltetrahydrofolate (5MTHF) and folic acid (FA) concentrations in persons aged ≥60 y are available in NHANES 1999–2002. The roundtable reviewed data that showed that folate concentrations from the Bio-Rad Quantaphase II procedure (Bio-Rad Laboratories, Hercules, CA; used in NHANES 1991–1994 and NHANES 1999–2006) were, on average, 29% lower for serum and 45% lower for RBC than were those from the microbiological assay (MA), which was used in NHANES 2007–2010. Roundtable experts agreed that these differences required a data adjustment for time-trend analyses. The roundtable reviewed the possible use of an isotope-dilution liquid chromatography–tandem mass spectrometry (LC-MS/MS) measurement procedure for future NHANES and agreed that the close agreement between the MA and LC-MS/MS results for serum folate supported conversion to the LC-MS/MS procedure. However, for RBC folate, the MA gave 25% higher concentrations than did the LC-MS/MS procedure. The roundtable agreed that the use of the LC-MS/MS procedure to measure RBC folate is premature at this time. The roundtable reviewed the reference materials available or under development at the National Institute of Standards and Technology and recognized the challenges related to, and the scientific need for, these materials. They noted the need for a commutability study for the available reference materials for serum 5MTHF and FA

    Biomarkers of vitamin B-12 status in NHANES: a roundtable summary123456

    Get PDF
    A roundtable to discuss the measurement of vitamin B-12 (cobalamin) status biomarkers in NHANES took place in July 2010. NHANES stopped measuring vitamin B-12–related biomarkers after 2006. The roundtable reviewed 3 biomarkers of vitamin B-12 status used in past NHANES—serum vitamin B-12, methylmalonic acid (MMA), and total homocysteine (tHcy)—and discussed the potential utility of measuring holotranscobalamin (holoTC) for future NHANES. The roundtable focused on public health considerations and the quality of the measurement procedures and reference methods and materials that past NHANES used or that are available for future NHANES. Roundtable members supported reinstating vitamin B-12 status measures in NHANES. They noted evolving concerns and uncertainties regarding whether subclinical (mild, asymptomatic) vitamin B-12 deficiency is a public health concern. They identified the need for evidence from clinical trials to address causal relations between subclinical vitamin B-12 deficiency and adverse health outcomes as well as appropriate cutoffs for interpreting vitamin B-12–related biomarkers. They agreed that problems with sensitivity and specificity of individual biomarkers underscore the need for including at least one biomarker of circulating vitamin B-12 (serum vitamin B-12 or holoTC) and one functional biomarker (MMA or tHcy) in NHANES. The inclusion of both serum vitamin B-12 and plasma MMA, which have been associated with cognitive dysfunction and anemia in NHANES and in other population-based studies, was preferable to provide continuity with past NHANES. Reliable measurement procedures are available, and National Institute of Standards and Technology reference materials are available or in development for serum vitamin B-12 and MMA
    corecore