9 research outputs found

    ПРИМЕНЕНИЕ ДВУХЭНЕРГЕТИЧЕСКОЙ КОМПЬЮТЕРНОЙ ТОМОГРАФИИ ДЛЯ ДИАГНОСТИКИ ГЕПАТОЦЕЛЛЮЛЯРНОЙ КАРЦИНОМЫ У ПАЦИЕНТКИ С ЦИРРОЗОМ ПЕЧЕНИ: СЛУЧАЙ ИЗ КЛИНИЧЕСКОЙ ПРАКТИКИ

    Get PDF
    Diagnosis and differential diagnosis of hepatic tumors is a topic that constantly has been widely discussed in the medical literature. Among new methods that can help solve the diagnostic issues - dual-energy computed tomography (DECT). DECT analysis of the absorption of two x-ray spectra allows obtaining additional information about the chemical composition of tissues. Scanners with the capability DECT ensured wide use of the method. Discovery 750 HD (GE Healthcare) is newly developed scanners which have overcome the temporal and spatial data mismatch and allowed the use of the DECT method in analyzing of the contrast agent distribution, with the function of fast switching voltages between 80 and 140 KW at intervals between the radiation of 0,25 MS. Discovery 750 HD installed in Krasnoyarsk regional Oncology center since 2014. In the article we described a clinical case of HCC diagnosis in cirrhotic patient with use of DECT. Presented case shows that DECT method improved the detectability of liver lesions and reduced the time spent on differential diagnosis.Диагностика и дифференциальная диагностика новообразований печени - тема, которая постоянно широко обсуждается в медицинской литературе. Среди новых методов, который может помочь решить поставленные перед диагностикой вопросы,- двухэнергетическая компьютерная томография (ДЭКТ). При ДЭКТ анализ поглощения не одного, а двух спектров рентгеновского излучения позволяет получить дополнительную информацию о химическом составе тканей. Широкое клиническое использование метода в последние годы связано с распространением томографов с функцией двухэнергетического сканирования, которые позволили преодолеть ошибки временного и пространственного несоответствия данных. Томограф «Discovery 750 HD» фирмы GE Healthcare, с функцией быстрого переключения напряжения между 80 и 140 КВт на рентгеновской трубке с интервалом между излучениями 0,25 мс, установлен в Красноярском краевом диспансере и характеризуется высокой точностью спектральных данных. В настоящей статье мы представляем клинический случай диагностики ГЦК у пациентки с циррозом печени. Обработка результатов исследования проведена с помощью широкого набора инструментов специализированных программ рабочей станции GE. Наше наблюдение демонстрирует возможность ДЭКТ повысить выявляемость образований печени и сократить время, затрачиваемое на их дифференциальную диагностику

    ПРИМЕНЕНИЕ ДВУХЭНЕРГЕТИЧЕСКОЙ КОМПЬЮТЕРНОЙ ТОМОГРАФИИ ДЛЯ ДИАГНОСТИКИ ГЕПАТОЦЕЛЛЮЛЯРНОЙ КАРЦИНОМЫ У ПАЦИЕНТКИ С ЦИРРОЗОМ ПЕЧЕНИ: СЛУЧАЙ ИЗ КЛИНИЧЕСКОЙ ПРАКТИКИ

    No full text
    Diagnosis and differential diagnosis of hepatic tumors is a topic that constantly has been widely discussed in the medical literature. Among new methods that can help solve the diagnostic issues - dual-energy computed tomography (DECT). DECT analysis of the absorption of two x-ray spectra allows obtaining additional information about the chemical composition of tissues. Scanners with the capability DECT ensured wide use of the method. Discovery 750 HD (GE Healthcare) is newly developed scanners which have overcome the temporal and spatial data mismatch and allowed the use of the DECT method in analyzing of the contrast agent distribution, with the function of fast switching voltages between 80 and 140 KW at intervals between the radiation of 0,25 MS. Discovery 750 HD installed in Krasnoyarsk regional Oncology center since 2014. In the article we described a clinical case of HCC diagnosis in cirrhotic patient with use of DECT. Presented case shows that DECT method improved the detectability of liver lesions and reduced the time spent on differential diagnosis.Диагностика и дифференциальная диагностика новообразований печени - тема, которая постоянно широко обсуждается в медицинской литературе. Среди новых методов, который может помочь решить поставленные перед диагностикой вопросы,- двухэнергетическая компьютерная томография (ДЭКТ). При ДЭКТ анализ поглощения не одного, а двух спектров рентгеновского излучения позволяет получить дополнительную информацию о химическом составе тканей. Широкое клиническое использование метода в последние годы связано с распространением томографов с функцией двухэнергетического сканирования, которые позволили преодолеть ошибки временного и пространственного несоответствия данных. Томограф «Discovery 750 HD» фирмы GE Healthcare, с функцией быстрого переключения напряжения между 80 и 140 КВт на рентгеновской трубке с интервалом между излучениями 0,25 мс, установлен в Красноярском краевом диспансере и характеризуется высокой точностью спектральных данных. В настоящей статье мы представляем клинический случай диагностики ГЦК у пациентки с циррозом печени. Обработка результатов исследования проведена с помощью широкого набора инструментов специализированных программ рабочей станции GE. Наше наблюдение демонстрирует возможность ДЭКТ повысить выявляемость образований печени и сократить время, затрачиваемое на их дифференциальную диагностику

    Genomic Designing for Climate-Smart Tomato

    No full text
    Tomato is the first vegetable consumed in the world. It is grown in very different conditions and areas, mainly in field for processing tomatoes while fresh-market tomatoes are often produced in greenhouses. Tomato faces many environmental stresses, both biotic and abiotic. Today many new genomic resources are available allowing an acceleration of the genetic progress. In this chapter, we will first present the main challenges to breed climate-smart tomatoes. The breeding objectives relative to productivity, fruit quality, and adaptation to environmental stresses will be presented with a special focus on how climate change is impacting these objectives. In the second part, the genetic and genomic resources available will be presented. Then, traditional and molecular breeding techniques will be discussed. A special focus will then be presented on ecophysiological modeling, which could constitute an important strategy to define new ideotypes adapted to breeding objectives. Finally, we will illustrate how new biotechnological tools are implemented and could be used to breed climate-smart tomatoes
    corecore