8 research outputs found

    Non-contrast enhanced MRI for efficiency evaluation of high-intensity focused ultrasound in adenomyosis ablation

    No full text
    AbstractObjective To investigate the value of T2-weighted imaging (T2WI) and diffusion-weighted imaging (DWI) in evaluating the therapeutic effect of high-intensity focused ultrasound (HIFU) in adenomyosis ablation.Material and methods One hundred eighty-nine patients with adenomyosis were treated with HIFU. The ablation areas on T2WI and DWI sequences were classified into different types: type I, relatively ill-defined rim or unrecognizable; subtype IIa, well-defined rim with hyperintensity; subtype IIb, well-defined rim with hypointensity. The volume of ablation areas on T2WI (VT2WI) and DWI (VDWI) was measured and compared with the non-perfused volume (NPV), and linear regression was conducted to analyze their correlation with NPV.Results The VT2WI of type I and type II (subtype IIa and subtype IIb) were statistically different from the corresponding NPV (p = 0.004 and 0.024, respectively), while no significant difference was found between the VDWI of type I and type II with NPV (p = 0.478 and 0.561, respectively). In the linear regression analysis, both VT2WI and VDWI were positively correlated with NPV, with R2 reaching 0.96 and 0.97, respectively.Conclusions Both T2WI and DWI have the potential for efficient evaluation of HIFU treatment in adenomyosis, and DWI can be a replacement for CE-T1WI to some extent

    Enhanced Degradation of Trichloroethene by Sodium Percarbonate Activated with Fe (II) in the Presence of Citric Acid

    No full text
    Trichloroethene (TCE) degradation by Fe(II)-activated sodium percarbonate (SPC) in the presence of citric acid (CA) in aqueous solution was investigated. The results indicated that the presence of CA enhanced TCE degradation significantly by promoting HO• generation. The presence of Cl−, HCO3− and the initial solution pH appeared to be not negligible on the effect of TCE oxidation, while humic acid had no influence on TCE degradation. The generation of HO• and O2−• in the SPC/Fe(II)/CA system was confirmed with chemical probes, and the radical scavenging tests showed that TCE degradation was due to direct oxidation by HO•. Acidic pH condition was favorable for TCE degradation. In summary, this study provided detailed information for the application of the CA-enhanced Fe(II)-activated SPC technique for TCE-contaminated groundwater remediation

    Are medical record front page data suitable for risk adjustment in hospital performance measurement? Development and validation of a risk model of in-hospital mortality after acute myocardial infarction

    No full text
    Objectives To develop a model of in-hospital mortality using medical record front page (MRFP) data and assess its validity in case-mix standardisation by comparison with a model developed using the complete medical record data.Design A nationally representative retrospective study.Setting Representative hospitals in China, covering 161 hospitals in modelling cohort and 156 hospitals in validation cohort.Participants Representative patients admitted for acute myocardial infarction. 8370 patients in modelling cohort and 9704 patients in validation cohort.Primary outcome measures In-hospital mortality, which was defined explicitly as death that occurred during hospitalisation, and the hospital-level risk standardised mortality rate (RSMR).Results A total of 14 variables were included in the model predicting in-hospital mortality based on MRFP data, with the area under receiver operating characteristic curve of 0.78 among modelling cohort and 0.79 among validation cohort. The median of absolute difference between the hospital RSMR predicted by hierarchical generalised linear models established based on MRFP data and complete medical record data, which was built as ‘reference model’, was 0.08% (10th and 90th percentiles: −1.8% and 1.6%). In the regression model comparing the RSMR between two models, the slope and intercept of the regression equation is 0.90 and 0.007 in modelling cohort, while 0.85 and 0.010 in validation cohort, which indicated that the evaluation capability from two models were very similar.Conclusions The models based on MRFP data showed good discrimination and calibration capability, as well as similar risk prediction effect in comparison with the model based on complete medical record data, which proved that MRFP data could be suitable for risk adjustment in hospital performance measurement

    360 degree view of cross-domain opinion classification: a survey

    No full text
    corecore