310 research outputs found

    Performance characterizations and thermodynamic analysis of magnesium sulfate-impregnated zeolite 13X and activated alumina composite sorbents for thermal energy storage

    Get PDF
    The composite sorbents of MgSO4-impregnated zeolite 13X and activated alumina are developed for thermal energy storage (TES) with different temperature ranges. The sorption and desorption characteristics of raw and MgSO4-impregnated activated alumina are studied, and the performances of the selected sorbents are tested in a closed-system TES device. The results are compared with those of raw and MgSO4-impregnated zeolite 13X. It is shown that the impregnated MgSO4 improves the overall TES performances of zeolite 13X and activated alumina. Compared to the raw host matrices, the impregnated MgSO4 remarkably accelerates the temperature-rising rate of zeolite 13X to about three times and improves the temperature lift of activated alumina by 32.5%. The experimental energy storage densities of MgSO4-impregnated zeolite 13X and activated alumina are 123.4 kWh m−3and 82.6 kWh m−3, respectively. The sorption temperature region of activated alumina is more aligned with the preferred hydration temperature of MgSO4 in comparison with zeolite 13X. The hydration characteristics of MgSO4 can resolve the solution leakage issue of open systems. Thermodynamic analysis is conducted to evaluate the performances of the TES device with different sorbents. It is found that entransy can be used to assess thermally and electrically driven TES systems reasonably

    Identification of rice chromosome segment substitution line Z322-1-10 and mapping QTLs for agronomic traits from the F<sub>3</sub> population

    Get PDF
    Chromosome segment substitution lines (CSSLs) are powerful tools to combine naturally occurring genetic variants with favorable alleles in the same genetic backgrounds of elite cultivars. An elite CSSL Z322-1-10 was identified from advanced backcrosses between a japonica cultivar Nipponbare and an elite indica restorer Xihui 18 by SSR marker-assisted selection (MAS). The Z322-1-10 line carries five substitution segments distributed on chromosomes 1, 2, 5, 6 and 10 with an average length of 4.80 Mb. Spikilets per panicle, 1000-grain weight, grain length in the Z322-1-10 line are significantly higher than those in Nipponbare. Quantitative trait loci (QTLs) were identified and mapped for nine agronomic traits in an F3 population derived from the cross between Nipponbare and Z322-1-10 using the restricted maximum likelihood (REML) method in the HPMIXED procedure of SAS. We detected 13 QTLs whose effect ranging from 2.45% to 44.17% in terms of phenotypic variance explained. Of the 13 loci detected, three are major QTL (qGL1, qGW5-1 and qRLW5-1) and they explain 34.68%, 44.17% and 33.05% of the phenotypic variance. The qGL1 locus controls grain length with a typical Mendelian dominance inheritance of 3:1 ratio for long grain to short grain. The already cloned QTL qGW5-1 is linked with a minor QTL for grain width qGW5-2 (13.01%) in the same substitution segment. Similarly, the previously reported qRLW5-1 is also linked with a minor QTL qRLW5-2. Not only the study is important for fine mapping and cloning of the gene qGL1, but also has a great potential for molecular breeding

    A zeolite 13X/magnesium sulfate–water sorption thermal energy storage device for domestic heating

    Get PDF
    A sorption thermal energy storage (TES) device for domestic heating is presented in this article. The TES device adopts the new design scenario with valve-less adsorber and separate reservoir to eliminate the large-diameter vacuum valve for vapor flow, which decreases the cost, reduces the vapor flow resistance, and improves the system reliability. The device is charged by the electric heater, which can add much flexibility to the building energy system as well as contribute to the valley filling and peak shaving from demand side management. The newly developed composite sorbent of zeolite 13X/MgSO4/ENG-TSA (expanded natural graphite treated with sulfuric acid) with the salt mass fraction of 15% in the zeolite 13X/MgSO4 mixture is tested and used in the TES device (denoted as XM15/ENG-TSA). Experimental results show that the TES device with XM15/ENG-TSA has the energy storage density of 120.3kWh∙m−3 at 250°C charging temperature and 25–90°C discharging temperature. The temperature lift is as high as 65–69°C with the adsorption and evaporating temperatures of 25°C. The impregnation of MgSO4 dramatically improves the temperature rising rate during the adsorption heat recovery process, but the specific energy storage capacity of XM15/ENG-TSA is similar to that of zeolite 13X/ENG-TSA. The effect of the impregnated MgSO4 suggests that MgSO4 can be used for low-temperature TES to relieve the self-hindrance of the hydration reaction

    Asymmetric influence of vocalic context on Mandarin sibilants: Evidence from ERP studies

    Get PDF
    In the present study, we examine the interactive effect of vowels on Mandarin fricative sibilants using a passive oddball paradigm to determine whether the HEIGHT features of vowels can spread on the surface and influence preceding consonants with unspecified features. The stimuli are two pairs of Mandarin words ([sa] ∼ [ʂa] and [su] ∼ [ʂu]) contrasting in vowel HEIGHT ([LOW] vs. [HIGH]). Each word in the same pair was presented both as standard and deviant, resulting in four conditions (/standard/[deviant]: /sa/[ʂa] ∼ /ʂa/[sa] and /su/[ʂu] ∼ /ʂu/[su]). In line with the Featurally Underspecified Lexicon (FUL) model, asymmetric patterns of processing were found in the [su] ∼ [ʂu] word pair where both the MMN (mismatch negativity) and LDN (late discriminative negativity) components were more negative in /su/[ʂu] (mismatch) than in /ʂu/[su] (no mismatch), suggesting the spreading of the feature [HIGH] from the vowel [u] to [ʂ] on the surface. In the [sa] ∼ [ʂa] pair, however, symmetric negativities (for both MMN and LDN) were observed as there is no conflict between the surface feature [LOW] from [a] to [ʂ] and the underlying specified feature [LOW] of [s]. These results confirm that not all features are fully specified in the mental lexicon: features of vowels can spread on the surface and influence surrounding unspecified segments

    Split First Dose Administration of Intravenous Daratumumab for the Treatment of Multiple Myeloma (MM) : Clinical and Population Pharmacokinetic Analyses

    Get PDF
    Introduction: Daratumumab, a human immunoglobulin Gκ monoclonal antibody targeting CD38, is approved as monotherapy and in combination with standard-of-care regimens for multiple myeloma. In clinical studies, the median durations of the first, second, and subsequent intravenous infusions of daratumumab were 7.0, 4.3, and 3.4 h, respectively. Splitting the first intravenous infusion of daratumumab over 2 days is an approved alternative dosing regimen to reduce the duration of the first infusion and provide flexibility for patients and healthcare providers. Methods: The feasibility of splitting the first 16-mg/kg infusion into two separate infusions of 8 mg/kg on Days 1 and 2 of the first treatment cycle was investigated in two cohorts [daratumumab, carfilzomib, and dexamethasone (D-Kd) and daratumumab, carfilzomib, lenalidomide, and dexamethasone (D-KRd)] of the phase 1b MMY1001 study. Additionally, a population pharmacokinetic (PK) analysis and simulations were used to compare the PK profiles of the split first dose regimen with the recommended single first dose regimens of daratumumab in previously approved indications. Results: In MMY1001, following administration of the second half of a split first dose on Cycle 1 Day 2, postinfusion median (range) daratumumab concentrations were similar between split first dose [D-Kd, 254.9 (125.8-435.5) µg/ml; D-KRd, 277.2 (164.0-341.8) µg/ml; combined, 256.8 (125.8-435.5) µg/ml] and single first dose [D-Kd, 319.2 (237.5-394.7) µg/ml]. At the end of weekly dosing, median (range) Cycle 3 Day 1 preinfusion daratumumab concentrations were similar between split first dose [D-Kd, 663.9 (57.7-1110.7) µg/ml; D-KRd, 575.1 (237.9-825.5) µg/ml; combined, 639.2 (57.7-1110.7) µg/ml] and single first dose [D-Kd, 463.2 (355.9-792.9) µg/ml]. The population PK simulations demonstrated virtually identical PK profiles after the first day of treatment for all approved indications and recommended dosing schedules of daratumumab. Conclusion: These data support the use of an alternative split first dose regimen of intravenous daratumumab for the treatment of MM. Trial Registration: ClinicalTrials.gov number, NCT01998971

    Split First Dose Administration of Intravenous Daratumumab for the Treatment of Multiple Myeloma (MM) : Clinical and Population Pharmacokinetic Analyses

    Get PDF
    Introduction: Daratumumab, a human immunoglobulin Gκ monoclonal antibody targeting CD38, is approved as monotherapy and in combination with standard-of-care regimens for multiple myeloma. In clinical studies, the median durations of the first, second, and subsequent intravenous infusions of daratumumab were 7.0, 4.3, and 3.4 h, respectively. Splitting the first intravenous infusion of daratumumab over 2 days is an approved alternative dosing regimen to reduce the duration of the first infusion and provide flexibility for patients and healthcare providers. Methods: The feasibility of splitting the first 16-mg/kg infusion into two separate infusions of 8 mg/kg on Days 1 and 2 of the first treatment cycle was investigated in two cohorts [daratumumab, carfilzomib, and dexamethasone (D-Kd) and daratumumab, carfilzomib, lenalidomide, and dexamethasone (D-KRd)] of the phase 1b MMY1001 study. Additionally, a population pharmacokinetic (PK) analysis and simulations were used to compare the PK profiles of the split first dose regimen with the recommended single first dose regimens of daratumumab in previously approved indications. Results: In MMY1001, following administration of the second half of a split first dose on Cycle 1 Day 2, postinfusion median (range) daratumumab concentrations were similar between split first dose [D-Kd, 254.9 (125.8-435.5) µg/ml; D-KRd, 277.2 (164.0-341.8) µg/ml; combined, 256.8 (125.8-435.5) µg/ml] and single first dose [D-Kd, 319.2 (237.5-394.7) µg/ml]. At the end of weekly dosing, median (range) Cycle 3 Day 1 preinfusion daratumumab concentrations were similar between split first dose [D-Kd, 663.9 (57.7-1110.7) µg/ml; D-KRd, 575.1 (237.9-825.5) µg/ml; combined, 639.2 (57.7-1110.7) µg/ml] and single first dose [D-Kd, 463.2 (355.9-792.9) µg/ml]. The population PK simulations demonstrated virtually identical PK profiles after the first day of treatment for all approved indications and recommended dosing schedules of daratumumab. Conclusion: These data support the use of an alternative split first dose regimen of intravenous daratumumab for the treatment of MM. Trial Registration: ClinicalTrials.gov number, NCT01998971

    The ARGO-YBJ Experiment Progresses and Future Extension

    Full text link
    Gamma ray source detection above 30TeV is an encouraging approach for finding galactic cosmic ray origins. All sky survey for gamma ray sources using wide field of view detector is essential for population accumulation for various types of sources above 100GeV. To target the goals, the ARGO-YBJ experiment has been established. Significant progresses have been made in the experiment. A large air shower detector array in an area of 1km2 is proposed to boost the sensitivity. Hybrid detection with multi-techniques will allow a good discrimination between different types of primary particles, including photons and protons, thus enable an energy spectrum measurement for individual specie. Fluorescence light detector array will extend the spectrum measurement above 100PeV where the second knee is located. An energy scale determined by balloon experiments at 10TeV will be propagated to ultra high energy cosmic ray experiments

    Direct Measurements of the Branching Fractions for D0→K−e+νeD^0 \to K^-e^+\nu_e and D0→π−e+νeD^0 \to \pi^-e^+\nu_e and Determinations of the Form Factors f+K(0)f_{+}^{K}(0) and f+π(0)f^{\pi}_{+}(0)

    Get PDF
    The absolute branching fractions for the decays D0→K−e+νeD^0 \to K^-e ^+\nu_e and D0→π−e+νeD^0 \to \pi^-e^+\nu_e are determined using 7584±198±3417584\pm 198 \pm 341 singly tagged Dˉ0\bar D^0 sample from the data collected around 3.773 GeV with the BES-II detector at the BEPC. In the system recoiling against the singly tagged Dˉ0\bar D^0 meson, 104.0±10.9104.0\pm 10.9 events for D0→K−e+νeD^0 \to K^-e ^+\nu_e and 9.0±3.69.0 \pm 3.6 events for D0→π−e+νeD^0 \to \pi^-e^+\nu_e decays are observed. Those yield the absolute branching fractions to be BF(D0→K−e+νe)=(3.82±0.40±0.27)BF(D^0 \to K^-e^+\nu_e)=(3.82 \pm 0.40\pm 0.27)% and BF(D0→π−e+νe)=(0.33±0.13±0.03)BF(D^0 \to \pi^-e^+\nu_e)=(0.33 \pm 0.13\pm 0.03)%. The vector form factors are determined to be ∣f+K(0)∣=0.78±0.04±0.03|f^K_+(0)| = 0.78 \pm 0.04 \pm 0.03 and ∣f+π(0)∣=0.73±0.14±0.06|f^{\pi}_+(0)| = 0.73 \pm 0.14 \pm 0.06. The ratio of the two form factors is measured to be ∣f+π(0)/f+K(0)∣=0.93±0.19±0.07|f^{\pi}_+(0)/f^K_+(0)|= 0.93 \pm 0.19 \pm 0.07.Comment: 6 pages, 5 figure

    Search for the Lepton Flavor Violation Processes J/ψ→J/\psi \to μτ\mu\tau and eτe\tau

    Full text link
    The lepton flavor violation processes J/ψ→μτJ/\psi \to \mu\tau and eτe\tau are searched for using a sample of 5.8×107\times 10^7 J/ψJ/\psi events collected with the BESII detector. Zero and one candidate events, consistent with the estimated background, are observed in J/ψ→μτ,τ→eνˉeντJ/\psi \to \mu\tau, \tau\to e\bar\nu_e\nu_{\tau} and J/ψ→eτ,τ→μνˉμντJ/\psi\to e\tau, \tau\to\mu\bar\nu_{\mu}\nu_{\tau} decays, respectively. Upper limits on the branching ratios are determined to be Br(J/ψ→μτ)<2.0×10−6Br(J/\psi\to\mu\tau)<2.0 \times 10^{-6} and Br(J/ψ→eτ)<8.3×10−6Br(J/\psi \to e\tau) < 8.3 \times10^{-6} at the 90% confidence level (C.L.).Comment: 9 pages, 2 figure

    The σ\sigma pole in J/ψ→ωπ+π−J/\psi \to \omega \pi^+ \pi^-

    Full text link
    Using a sample of 58 million J/ψJ/\psi events recorded in the BESII detector, the decay J/ψ→ωπ+π−J/\psi \to \omega \pi^+ \pi^- is studied. There are conspicuous ωf2(1270)\omega f_2(1270) and b1(1235)πb_1(1235)\pi signals. At low ππ\pi \pi mass, a large broad peak due to the σ\sigma is observed, and its pole position is determined to be (541±39)(541 \pm 39) - ii (252±42)(252 \pm 42) MeV from the mean of six analyses. The errors are dominated by the systematic errors.Comment: 15 pages, 6 figures, submitted to PL
    • …
    corecore