65 research outputs found
Anterolateral approach with tibial tubercle osteotomy versus standard medial approach for primary total knee arthroplasty: does it matter?
The purpose of this prospective consecutive multicenter study was to investigate whether the type of surgical approach (medial parapatellar (MPA) or lateral parapatellar with tibial tubercle osteotomy (TubOT)) influences the early clinical and radiological outcomes of primary total knee arthroplasty (TKA)
ASB9 interacts with ubiquitous mitochondrial creatine kinase and inhibits mitochondrial function
<p>Abstract</p> <p>Background</p> <p>The ankyrin repeat and suppressor of cytokine signalling (SOCS) box proteins (Asbs) are a large protein family implicated in diverse biological processes including regulation of proliferation and differentiation. The SOCS box of Asb proteins is important in a ubiquitination-mediated proteolysis pathway. Here, we aimed to evaluate expression and function of human Asb-9 (ASB9).</p> <p>Results</p> <p>We found that a variant of ASB9 that lacks the SOCS box (ASB9ΔSOCS) was naturally detected in human cell lines but not in peripheral blood mononuclear cells or normal hepatocytes. We also identified ubiquitous mitochondrial creatine kinase (uMtCK) as a new target of ASB9 in human embryonic kidney 293 (HEK293) cells. The ankyrin repeat domains of ASB9 can associate with the substrate binding site of uMtCK in a SOCS box-independent manner. The overexpression of ASB9, but not ASB9ΔSOCS, induces ubiquitination of uMtCK. ASB9 and ASB9ΔSOCS can interact and colocalise with uMtCK in the mitochondria. However, only expression of ASB9 induced abnormal mitochondrial structure and a decrease of mitochondrial membrane potential. Furthermore, the creatine kinase activities and cell growth were significantly reduced by ASB9 but not by ASB9ΔSOCS.</p> <p>Conclusions</p> <p>ASB9 interacts with the creatine kinase system and negatively regulates cell growth. The differential expression and function of ASB9 and ASB9ΔSOCS may be a key factor in the growth of human cell lines and primary cells.</p
Fully automated, inline quantification of myocardial blood flow with cardiovascular magnetic resonance: repeatability of measurements in healthy subjects
Background: Non-invasive assessment of myocardial ischaemia is a cornerstone of the diagnosis of coronary artery disease. Measurement of myocardial blood flow (MBF) using positron emission tomography (PET) is the current reference standard for non-invasive quantification of myocardial ischaemia. Dynamic myocardial perfusion cardiovascular magnetic resonance (CMR) offers an alternative to PET and a recently developed method with automated inline perfusion mapping has shown good correlation of MBF values between CMR and PET. This study assessed the repeatability of myocardial perfusion mapping by CMR in healthy subjects.
Methods: Forty-two healthy subjects were recruited and underwent adenosine stress and rest perfusion CMR on two visits. Scans were repeated with a minimum interval of 7 days. Intrastudy rest and stress MBF repeatability were assessed with a 15-min interval between acquisitions. Interstudy rest and stress MBF and myocardial perfusion reserve (MPR) were measured for global myocardium and regionally for coronary territories and slices.
Results: There was no significant difference in intrastudy repeated global rest MBF (0.65 ± 0.13 ml/g/min vs 0.62 ± 0.12 ml/g/min, p = 0.24, repeatability coefficient (RC) =24%) or stress (2.89 ± 0.56 ml/g/min vs 2.83 ± 0.64 ml/g/min, p = 0.41, RC = 29%) MBF. No significant difference was seen in interstudy repeatability for global rest MBF (0.64 ± 0.13 ml/g/min vs 0.64 ± 0.15 ml/g/min, p = 0.80, RC = 32%), stress MBF (2.71 ± 0.61 ml/g/min vs 2.55 ± 0.57 ml/g/min, p = 0.12, RC = 33%) or MPR (4.24 ± 0.69 vs 3.73 ± 0.76, p = 0.25, RC = 36%). Regional repeatability was good for stress (RC = 30–37%) and rest MBF (RC = 32–36%) but poorer for MPR (RC = 35–43%). Within subject coefficient of variation was 8% for rest and 11% for stress within the same study, and 11% for rest and 12% for stress between studies.
Conclusions: Fully automated, inline, myocardial perfusion mapping by CMR shows good repeatability that is similar to the published PET literature. Both rest and stress MBF show better repeatability than MPR, particularly in regional analysis
Ultrasound for the evaluation of femoroacetabular impingement of the cam type. Diagnostic performance of qualitative criteria and alpha angle measurements
OBJECTIVE: To develop and assess a technique to evaluate cam type femoroacetabular impingement (FAI) using ultrasound (US). METHODS: Fifty patients (24 women, 26 men) were included (mean age: 39.1 years; age range: 16-59). US images of the anterior and anterosuperior contour of the femoral neck were obtained and analysed in 50 patients. Non-spherical shape of the head-neck junction (cam deformity), bony protuberances at the femoral neck, shape of the femoral neck (waist deficiency) and alpha angle were assessed. Magnetic resonance (MR) arthrography served as the standard of reference. Diagnostic performance and receiver operating characteristics (ROC) curves were calculated. RESULTS: Based on MR arthrography 28 patients had cam-type FAI. On US, an anterosuperior cam deformity was seen in 40/44 patients (Reader 1/Reader 2; sensitivity 93%/89%, specificity 36%/14%). A bony protuberance anterosuperiorly in 23/13 patients (sensitivity 71%/32%, specificity 86%/82%) and an anterosuperior waist deficiency in 19/35 patients (sensitivity 25%/54%, specificity 100%/54%). Sensitivity and specificity of the other criteria were lower than 70% (average of Reader 1 & 2). CONCLUSION: A technique to evaluate cam type FAI using US is presented. The detection of an anterosuperior cam deformity is sensitive, and presence of an anterosuperior bony protuberance is specific for cam FAI. Alpha angle measurements are not helpful in establishing the diagnosis
- …