56 research outputs found

    Kollegiale Unterrichtsreflexion im Lehramtsstudium

    Full text link
    Die Verfasserinnen präsentieren in ihrem Beitrag ausgewählte Ergebnisse einer empirischen Untersuchung zu verschiedenen Reflexionssettings von Lehramtsstudierenden im Quartalspraktikum an der PH Zürich. Die Studie verweist auf verschiedene Faktoren, welche die Nützlichkeit der Peer-Reflexionsgespräche maßgeblich beeinflussen und liefert interessante Impulse für das Geben eines kritisch-konstruktiven Peer-to-Peer-Feedbacks. (DIPF/Orig.

    Coronary calcium score scans for attenuation correction of quantitative PET/CT 13N-ammonia myocardial perfusion imaging

    Get PDF
    Purpose: The aim of this study was to evaluate whether ECG-triggered coronary calcium scoring (CCS) scans can be used for attenuation correction (AC) to quantify myocardial blood flow (MBF) and coronary flow reserve (CFR) assessed by PET/CT with 13N-ammonia. Methods: Thirty-five consecutive patients underwent a 13N-ammonia PET/CT scan at rest and during standard adenosine stress. MBF values were calculated using AC maps obtained from the ECG-triggered CCS scan during inspiration and validated against MBF values calculated using standard non-gated transmission scans for AC. CFR was calculated as the ratio of hyperaemic over resting MBF. In all 35 consecutive patients intraobserver variability was assessed by blinded repeat analysis for both AC methods. Results: There was an excellent correlation between CT AC and CCS for global MBF values at rest (n = 35, r = 0.94, p < 0.001) and during stress (n = 35, r = 0.97, p < 0.001) with narrow Bland-Altman (BA) limits of agreement (−0.21 to 0.10ml/min per g and −0.41 to 0.30ml/min per g) as well as for global CFR (n = 35, r = 0.96, p < 0.001, BA −0.27 to 0.34). The excellent correlation was preserved on the segmental MBF analysis for both rest and stress (n = 1190, r = 0.93, p < 0.001, BA −0.60 to 0.50) and for CFR (n = 595, r = 0.87, p < 0.001, BA −0.71 to 0.74). In addition, reproducibility proved excellent for global CFR by CT AC (n = 35, r = 0.91, p < 0.001, BA −0.42-0.58) and CCS scans (n = 35, r = 0.94, p < 0.001, BA −0.34-0.45). Conclusion: Use of attenuation maps from CCS scans allows accurate quantitative MBF and CFR assessment with 13N-ammonia PET/C

    Body physique and heart rate variability determine the occurrence of stair-step artefacts in 64-slice CT coronary angiography with prospective ECG-triggering

    Get PDF
    The purpose of this study was to describe and characterize the frequency and extent of stair-step artefacts in computed tomography coronary angiography (CTCA) with prospective electrocardiogram (ECG)-triggering and to identify their determinants. One hundred and forty three consecutive patients (55 women, mean age 57 ± 13years) underwent 64-slice CTCA using prospective ECG-triggering. Occurrence of stair-step artefacts in CTCA of the thoracic wall and the coronary arteries was determined and maximum offset was measured. If stair-step artefacts occurred in both cases, a difference between thoracic wall and coronary artery offset of 0.6mm or greater was attributed to additional motion of the heart. Mean effective radiation dose was 2.1 ± 0.7mSv (range 1.0-3.5mSv). Eighty-nine patients (62%) had stair-step artefacts in CTCA of the coronary arteries (mean offset of 1.7 ± 1.1mm), while only 77 patients had thoracic wall stair-step artefacts (mean offset of 1.0 ± 0.3mm; significantly different, P < 0.001). Stair-step artefacts in CTCA of the thoracic wall were determined by BMI and weight (P < 0.01), while artefacts in CTCA of the coronary arteries were associated with heart rate variability (P < 0.05). Stair-step artefacts in CTCA with prospective ECG-triggering are determined by (a) motion of the entire patient during table travel, particularly in large patients and (b) by motion of the heart, particularly when heart rates are variabl

    Determinants of vessel contrast in BMI-adapted low dose CT coronary angiography with prospective ECG-triggering

    Get PDF
    We evaluated the determinants of vessel contrast in prospectively ECG-triggered CT coronary angiography (CTCA). Seventy patients underwent low-dose CTCA using Body Mass Index (BMI)-adapted tube parameters and a fixed contrast material bolus. Contrast to noise ratio (CNR) was calculated from contrast (between coronaries and perivascular tissue) and image noise (standard deviation of aortic attenuation). Cardiac output (CO) was calculated from gated 99mTc-tetrofosmin-SPECT. Mean radiation dose was 2.13±0.69mSv. Image noise was not affected by BMI (r=0.1, P=0.36), while CNR was inversely related to body surface area (BSA) (r=−0.5, P<0.001) and CO (r=−0.45, P<0.001). After successfully overcoming the impact of BMI on image noise by adapting tube parameters, CNR mainly depends on coronary vessel contrast. The latter reflects the dilution of the contrast material by blood volume and CO, which are both correlated to BSA. Therefore, BSA adapted contrast administration may help to compensate for this effec

    Diagnostic accuracy of computed tomography coronary angiography and evaluation of stress-only single-photon emission computed tomography/computed tomography hybrid imaging: comparison of prospective electrocardiogram-triggering vs. retrospective gating

    Get PDF
    Aims To determine diagnostic accuracy, effective radiation dose, and potential value of computed tomography coronary angiography (CTCA) for hybrid imaging with single-photon emission computed tomography (SPECT) comparing prospective electrocardiogram (ECG)-triggering vs. retrospective ECG-gating. Methods and results Two hundred patients underwent standard myocardial stress/rest- SPECT perfusion imaging, which served as standard of reference. One hundred consecutive patients underwent 64-slice CTCA using prospective ECG-gating, and were compared with 100 patients who had previously undergone CTCA using retrospective ECG-gating. For predicting ischaemia, CTCA with prospective ECG-triggering and a stenosis cut-off >50% had a per-vessel sensitivity, specificity, negative, and positive predictive value of 100, 84, 100, and 30%; respective values for CTCA with retrospective ECG-gating were similar (P = n.s.): 86, 83, 98, and 33%. Combining CTCA with stress-only SPECT revealed 100% clinical agreement with regard to perfusion defects, and provided additional information in half the patients on preclinical coronary findings. Effective radiation dose was 2.2 ± 0.7 mSv for CTCA with prospective ECG-triggering, and 19.7 ± 4.2 mSv with retrospective ECG-gating (P < 0.001) (5.4 ± 0.8 vs. 24.1 ± 4.3 mSv for hybrid imaging). Conclusion Prospective ECG-triggering for CTCA reduces radiation dose by almost 90% without affecting diagnostic performance. Combined imaging with stress-only SPECT is an attractive alternative to standard stress/rest-SPECT for evaluation of coronary artery disease, offering additional information on preclinical atherosclerosi

    Pre-ischemic Lactate Levels Affect the Post-ischemic Recovery in an Isolated Rat Heart Model of Donation After Circulatory Death (DCD)

    Get PDF
    Introduction: Donation after circulatory death (DCD) could substantially improve donor heart availability. In DCD, the heart is not only exposed to a period of warm ischemia, but also to a damaging pre-ischemic phase. We hypothesized that the DCD-relevant pre-ischemic lactate levels negatively affect the post-ischemic functional and mitochondrial recovery in an isolated rat heart model of DCD. Methods: Isolated, working rat hearts underwent 28.5′ of global ischemia and 60′ of reperfusion. Prior to ischemia, hearts were perfused with one of three pre-ischemic lactate levels: no lactate (0 Lac), physiologic lactate (0.5 mM; 0.5 Lac), or DCD-relevant lactate (1 mM; 1 Lac). In a fourth group, an inhibitor of the mitochondrial calcium uniporter was added in reperfusion to 1 Lac hearts (1 Lac + Ru360). Results: During reperfusion, left ventricular work (heart rate-developed pressure product) was significantly greater in 0.5 Lac hearts compared to 0 Lac or 1 Lac. In 1 vs. 0.5 Lac hearts, in parallel with a decreased function, cellular and mitochondrial damage was greater, tissue calcium content tended to increase, while oxidative stress damage tended to decrease. The addition of Ru360 to 1 Lac hearts partially abrogated the negative effects of the DCD-relevant pre-ischemic lactate levels (greater post-ischemic left ventricular work and less cytochrome c release in 1 Lac+Ru360 vs. 1 Lac). Conclusion: DCD-relevant levels of pre-ischemic lactate (1 mM) reduce contractile, cellular, and mitochondrial recovery during reperfusion compared to physiologic lactate levels. Inhibition of mitochondrial calcium uptake during early reperfusion improves the post-ischemic recovery of 1 Lac hearts, indicating calcium overload as a potential therapeutic reperfusion target for DCD hearts

    Prevalence of noncardiac findings on low dose 64-slice computed tomography used for attenuation correction in myocardial perfusion imaging with SPECT

    Get PDF
    Electrocardiogram (ECG)-triggered, low dose computed tomography (CT) is increasingly used for attenuation correction in myocardial perfusion imaging (MPI) with SPECT. The purpose of the study was to assess the prevalence of relevant noncardiac findings in the field-of-view of such attenuation correction CT scans. Five hundred and eighty-two consecutive patients (211 female, 371 male; mean age: 64±11years; BMI: 27.7±5.3kg/m2) underwent 64-slice, ECG-triggered CT scanning for attenuation correction of MPI with SPECT. Relevant findings were defined as abnormalities that required clinical or radiological follow-up. Noncardiac findings were detected in 400 patients (68.7%). In 196 patients (33.7%) 226 relevant findings were detected. Findings included noncalcified pulmonary nodules (n=156), interstitial lung disease (n=6), pleural effusion (n=20), pneumonia (n=1), aortic aneurysm (n=5), aortic dissection (n=4), enlarged mediastinal lymph nodes (n=5), mediastinal tumor (n=3), breast abnormalities (n=3), liver cirrhosis (n=5), liver mass (n=5), ascites (n=5), splenomegaly (n=2), renal mass (n=1), hydronephrosis (n=1), adrenal mass (n=3), and bone metastasis (n=1). As low dose 64-slice CT scans used for attenuation correction in MPI with SPECT reveal a high prevalence of noncardiac pathologic findings with potential clinical relevance, a systematic review of the CT scans appears mandator

    Immune signatures predict development of autoimmune toxicity in patients with cancer treated with immune checkpoint inhibitors

    Full text link
    Background: Immune checkpoint inhibitors (ICIs) are among the most promising treatment options for melanoma and non-small cell lung cancer (NSCLC). While ICIs can induce effective anti-tumor responses, they may also drive serious immune-related adverse events (irAEs). Identifying biomarkers to predict which patients will suffer from irAEs would enable more accurate clinical risk-benefit analysis for ICI treatment and may also shed light on common or distinct mechanisms underpinning treatment success and irAEs. Methods: In this prospective multi-center study, we combined a multi-omics approach including unbiased single-cell profiling of over 300 peripheral blood mononuclear cell (PBMC) samples and high-throughput proteomics analysis of over 500 serum samples to characterize the systemic immune compartment of patients with melanoma or NSCLC before and during treatment with ICIs. Findings: When we combined the parameters obtained from the multi-omics profiling of patient blood and serum, we identified potential predictive biomarkers for ICI-induced irAEs. Specifically, an early increase in CXCL9/CXCL10/CXCL11 and interferon-γ (IFN-γ) 1 to 2 weeks after the start of therapy are likely indicators of heightened risk of developing irAEs. In addition, an early expansion of Ki-67+ regulatory T cells (Tregs) and Ki-67+ CD8+ T cells is also likely to be associated with increased risk of irAEs. Conclusions: We suggest that the combination of these cellular and proteomic biomarkers may help to predict which patients are likely to benefit most from ICI therapy and those requiring intensive monitoring for irAEs. Funding: This work was primarily funded by the European Research Council, the Swiss National Science Foundation, the Swiss Cancer League, and the Forschungsförderung of the Kantonsspital St. Gallen

    Longitudinal maturation of auditory cortical function during adolescence

    Get PDF
    Cross-sectional studies have demonstrated that the cortical auditory evoked potential (CAEP) changes substantially in amplitude and latency from childhood to adulthood, suggesting that these aspects of the CAEP continue to mature through adolescence. However, no study to date has longitudinally followed maturation of these CAEP measures through this developmental period. Additionally, no study has examined the trial-to-trial variability of the CAEP during adolescence. Therefore, we longitudinally tracked changes in the latency, amplitude, and variability of the P1, N1, P2, and N2 components of the CAEP in 68 adolescents from age 14 years to age 17 years. Latency decreased for N1 and N2, and did not change for P1 or P2. Amplitude decreased for P1 and N2, increased for N1, and did not change for P2. Variability decreased with age for all CAEP components. These findings provide longitudinal support for the view that the human auditory system continues to mature through adolescence. Continued auditory system maturation through adolescence suggests that CAEP neural generators remain plastic during this age range and potentially amenable to experience-based enhancement or deprivation
    corecore