4,249 research outputs found

    Fine Needle Aspiration Cytology of Metastatic Plasmacytoid Urothelial Carcinoma- Report of Four Cases Including a Case of Mixed Plasmacytoid and Micropapillary Morphology

    Get PDF
    Objectives: The aim of this study was to report a small series of fine-needle aspiration (FNA) cytology of the plasmacytoid variant of urothelial carcinoma (PVUC). Study Design: A computerized search of our laboratory information system was performed for the 5-year period between January 2008 and January 2013 to identify all FNA cases in which the corresponding surgical pathology cases were diagnosed as PVUC. Results: The 4 cases identified were from 2 men (aged 56 and 64 years) and 2 women (aged 72 and 46 years). The FNA smears demonstrated low-to-moderate cellularity and consisted predominantly of single and dyshesive, medium-sized tumor cells with eccentrically located nuclei and a moderate-to-abundant dense cytoplasm. The nuclei were oval with slightly irregular nuclear membranes and contained coarse granular chromatin with inconspicuous or small nucleoli. There was moderate nuclear variation in size. The nuclear-to-cytoplasmic ratio ranged from <1 to 3. Binucleation, cytoplasmic vacuoles, and perinuclear hof were occasionally seen. Conclusions: FNA cytology of PVUC shares features with plasma cell neoplasms, lobular carcinoma of the breast, and signet ring cell carcinoma of the stomach. Being aware of the patient's clinical history and the potential diagnostic pitfall of this rare variant of urothelial carcinoma is important for an accurate diagnosis on FNA biopsy

    Metal on Metal Bearing in Total Hip Arthroplasty and its Impact on Synovial Cell Count

    Get PDF
    Introduction: The effect of different bearings on synovial white blood cell (WBC) count and polymorphonuclear percentage (PMN%) in aspirations remains unclear. Therefore, this study investigates the impact of aseptic Metal-on-Metal (MoM) bearing on synovial fluid. Methods: We searched our arthroplasty registry for aseptic painful THAs with MoM bearings between 2011 and 2018. Then, a case-matched control group was selected with septic and aseptic Total Hip Arthroplasty (THA) with ceramic on a polyethylene (PE) bearing. The matching criteria consisted of gender, age +/-10 years, and time of aspiration (+/-2years). Periprosthetic Joint Infection (PJI) was defined according to the Infectious Diseases Society of America (IDSA), and Musculoskeletal Infection Society (MSIS) using bacterial cultures, sonication and histology. Results: In total, 19 patients who underwent hip aspiration with MoM bearing were identified. Five patients had to be excluded due to insufficient synovial fluid obtained (n = 2) or bacterial growth after sonication that was initially negative with the standard microbiological cultures (n = 3). As such, 14 were included. These patients were matched with 14 aseptic and 14 septic THAs with ceramic on a PE bearing, which constituted the control group. The mean serum chrome level was 20.0 ± 15.5 nmol/L and cobalt level 18.4 ± 22.1 nmol/L. The synovial WBC and PMN% varied significantly between MoM bearing group and the aseptic THA ceramic PE group (both p < 0.001), as well as the septic THA group (WBC p = 0.016, PMN% p < 0.001). Furthermore, the septic THA group had significantly higher CRP values than the aseptic MoM group (p = 0.016). Conclusion: MoM bearing shows significantly higher synovial WBC and PMN% when compared to aseptic THA with ceramic on PE bearing above the MSIS cut-off. This is an important consideration when diagnosing periprosthetic joint infection using the MSIS guidelines

    Breakage of intramedullary femoral nailing or femoral plating: how to prevent implant failure

    Get PDF
    Introduction: Intramedullary (IM) fixation is the dominant treatment for pertrochanteric and femoral shaft fractures. In comparison to plate osteosynthesis (PO), IM fixation offers greater biomechanical stability and reduced non-union rates. Due to the minimally invasive nature, IM fixations are less prone to approach-associated complications, such as soft-tissue damage, bleeding or postoperative infection, but they are more prone to fat embolism. A rare but serious complication, however, is implant failure. Thus, the aim of this study was to identify possible risk factors for intramedullary fixation (IMF) and plate osteosynthesis (PO) failure. Materials: and methods We searched our trauma surgery database for implant failure, intramedullary and plate osteosynthesis, after proximal-pertrochanteric, subtrochanteric-or femoral shaft fractures between 2011 and 2019. Implant failures in both the IMF and PO groups were included. Demographic data, fracture type, quality of reduction, duration between initial implantation and nail or plate failure, the use of cerclages, intraoperative microbiological samples, sonication, and, if available, histology were collected. Results: A total of 24 femoral implant failures were identified: 11 IMFs and 13 POs. The average age of patients in the IM group was 68.2 +/- 13.5 years and in the PO group was 65.6 +/- 15.0 years, with men being affected in 63.6% and 39.5% of cases, respectively. A proximal femoral nail (PFN) anti-rotation was used in 7 patients, a PFN in one and a gamma nail in two patients. A total of 6 patients required cerclage wires for additional stability. A combined plate and intramedullary fixation was chosen in one patient. Initially, all intramedullary nails were statically locked. Failures were observed 34.1 weeks after the initial surgery on average. Risk factors for implant failure included the application of cerclage wires at the level of the fracture (n = 5, 21%), infection (n = 2, 8%), and the use of an additional sliding screw alongside the femoral neck screw (n = 3, 13%). In all patients, non-union was diagnosed radiographically and clinically after 6 months (n = 24, 100%). In the event of PO failure, the placement of screws within all screw holes, and interprosthetic fixation were recognised as the major causes of failure. Conclusion: Intramedullary or plate osteosynthesis remain safe and reliable procedures in the treatment of proximal femoral fractures (pertrochanteric, subtrochanteric and femoral shaft fractures). Nevertheless, the surgeon needs to be aware of several implant-related limitations causing implant breakage. These may include the application of tension band wiring which can lead to a too rigid fixation, or placement of cerclage wires at the fracture site

    Tunable magnetic interaction at the atomic scale in oxide heterostructures

    Full text link
    We report on a systematic study of a number of structurally identical but chemically distinct transition metal oxides in order to determine how the material-specific properties such as the composition and the strain affect the properties at the interface of heterostructures. Our study considers a series of structures containing two layers of ferromagnetic SrRuO3, with antiferromagnetic insulating manganites sandwiched in between. The results demonstrate how to control the strength and relative orientation of interfacial ferromagnetism in correlated electron materials by means of valence state variation and substrate-induced strain, respectively

    The Impact of the Laterality on Radiographic Outcomes of the Bernese Periacetabular Osteotomy

    Get PDF
    The purpose of this study was to compare the pre and postoperative radiographic findings and analyze the complication rate with respect to the laterality in periacetabular osteotomy in right-handed surgeons. Satisfaction rate and radiographic findings were prospectively collected between 2017 and 2019 and retrospectively reviewed. For analysis, all measurements of the CT scans were performed by a musculoskeletal fellowship-trained radiologist. Complications were classified into two categories: perioperative or postoperative. All surgeries were performed by three right-hand dominant hip surgeons. A total of 41 dysplastic hips (25 right and 16 left hips) in 33 patients were included. Postoperatively, a significantly lower acetabular index angle on the left side was observed at -2.6 +/- 4.3 as compared to the right side at 1.6 +/- 6.5 (p < 0.05). The change in Center edge (CE) angle was significantly lower for the left side 13.7 +/- 5.5 degrees than on the right side, measured at 18.4 +/- 7.3 (p < 0.001); however, the overall CE angle was comparable at 38.5 +/- 8.9 degrees without any significant difference between the operated hips (left side at 37.8 +/- 6.1 degrees versus right side at 39.0 +/- 10.3; p = 0.340). No significant differences in other radiographic measurements or surgical time were observed. For complications, the right side was more commonly affected, which may also explain a higher satisfaction rate in patients who were operated on the left hip with 92.3%. The change in lateral CE angle was significantly lower for the left side and the right hip seems to be predisposed to complications, which correlate with a lower satisfaction rate in right-handed surgeons

    Ceftriaxone attenuates hypoxic-ischemic brain injury in neonatal rats

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Perinatal brain injury is the leading cause of subsequent neurological disability in both term and preterm baby. Glutamate excitotoxicity is one of the major factors involved in perinatal hypoxic-ischemic encephalopathy (HIE). Glutamate transporter GLT1, expressed mainly in mature astrocytes, is the major glutamate transporter in the brain. HIE induced excessive glutamate release which is not reuptaked by immature astrocytes may induce neuronal damage. Compounds, such as ceftriaxone, that enhance the expression of GLT1 may exert neuroprotective effect in HIE.</p> <p>Methods</p> <p>We used a neonatal rat model of HIE by unilateral ligation of carotid artery and subsequent exposure to 8% oxygen for 2 hrs on postnatal day 7 (P7) rats. Neonatal rats were administered three dosages of an antibiotic, ceftriaxone, 48 hrs prior to experimental HIE. Neurobehavioral tests of treated rats were assessed. Brain sections from P14 rats were examined with Nissl and immunohistochemical stain, and TUNEL assay. GLT1 protein expression was evaluated by Western blot and immunohistochemistry.</p> <p>Results</p> <p>Pre-treatment with 200 mg/kg ceftriaxone significantly reduced the brain injury scores and apoptotic cells in the hippocampus, restored myelination in the external capsule of P14 rats, and improved the hypoxia-ischemia induced learning and memory deficit of P23-24 rats. GLT1 expression was observed in the cortical neurons of ceftriaxone treated rats.</p> <p>Conclusion</p> <p>These results suggest that pre-treatment of infants at risk for HIE with ceftriaxone may reduce subsequent brain injury.</p

    The Impact of Hip Dysplasia on CAM Impingement

    Get PDF
    Predisposing factors for CAM-type femoroacetabular impingement (FAI) include acetabular protrusion and retroversion; however, nothing is known regarding development in dysplastic hips. The purpose of this study was to determine the correlation between CAM-type FAI and developmental dysplastic hips diagnosed using X-ray and rotational computed tomography. In this retrospective study, 52 symptomatic hips were included, with a mean age of 28.8 +/- 7.6 years. The inclusion criteria consisted of consecutive patients who suffered from symptomatic dysplastic or borderline dysplastic hips and underwent a clinical examination, conventional radiographs and rotational computed tomography. Demographics, standard measurements and the rotational alignments were recorded and analyzed between the CAM and nonCAM groups. Among the 52 patients, 19 presented with CAM impingement, whereas, in 33 patients, no signs of CAM impingement were noticed. For demographics, no significant differences between the two groups were identified. On conventional radiography, the acetabular hip index as well as the CE angle for the development of CAM impingement were significantly different compared to the nonCAM group with a CE angle of 21.0 degrees +/- 5.4 degrees vs. 23.7 degrees +/- 5.8 degrees (p = 0.050) and an acetabular hip index of 25.6 +/- 5.7 vs. 21.9 +/- 7.3 (p = 0.031), respectively. Furthermore, a crossing over sign was observed to be more common in the nonCAM group, which is contradictory to the current literature. For rotational alignment, no significant differences were observed. In dysplastic hips, the CAM-type FAI correlated to a lower CE angle and a higher acetabular hip index. In contrast to the current literature, no significant correlations to the torsional alignment or to crossing over signs were observed

    App-based rehabilitation program after total knee arthroplasty: a randomized controlled trial

    Get PDF
    Introduction: New app-based programs for postoperative rehabilitation have been developed, but no long-term study has been published to date. Thus, a prospective randomized control trial with 2-year follow-up was performed to evaluate the effectiveness of app-based rehabilitation (GenuSport) compared to a control group after total knee arthroplasty (TKA). Methods: Between April and October 2016, 60 patients were enrolled in the study. Twenty-five patients were lost to follow-up, leaving 35 patients undergoing TKA for inclusion. In this group, twenty patients received app-based exercise program and 15 were randomized to the control group. The mean age was 64.37 +/- 9.32 years with a mean follow-up of 23.51 +/- 1.63 months. Patients in the app group underwent an app-based knee training starting on the day of surgery; whereas, patients in the control group underwent regular physiotherapy. Functional outcome scores using the Knee Injury and Osteoarthritis Outcome Score (KOOS), Knee Society Score (KSS) and VAS of pain were analyzed. Results: In the short term, significant differences between the app group and control group in time of 10-m walk (19.66 +/- 7.80 vs. 27.08 +/- 15.46 s; p = 0.029), VAS pain at rest and activity (2.65 +/- 0.82 vs. 3.57 +/- 1.58, respectively 4.03 +/- 1.26 vs. 5.05 +/- 1.21; p < 0.05) were observed. In the long term, a variety of different tendencies was found, highest in KSS Function with 76.32 +/- 16.49 (app group) vs. 67.67 +/- 16.57 (control group) (p = 0.130). Additionally, patients in the app group required less painkillers (10.0% vs. 26.7%) and more likely to participate in sports (65.0% vs. 53.3%). Conclusions: An app-based knee trainer is a promising tool in improving functional outcomes such as KSS function score and VAS after TKA

    Gene therapy for follistatin mitigates systemic metabolic inflammation and post-traumatic arthritis in high-fat diet-induced obesity

    Get PDF
    Obesity-associated inflammation and loss of muscle function play critical roles in the development of osteoarthritis (OA); thus, therapies that target muscle tissue may provide novel approaches to restoring metabolic and biomechanical dysfunction associated with obesity. Follistatin (FST), a protein that binds myostatin and activin, may have the potential to enhance muscle formation while inhibiting inflammation. Here, we hypothesized that adeno-associated virus 9 (AAV9) delivery of FST enhances muscle formation and mitigates metabolic inflammation and knee OA caused by a high-fat diet in mice. AAV-mediated FST delivery exhibited decreased obesity-induced inflammatory adipokines and cytokines systemically and in the joint synovial fluid. Regardless of diet, mice receiving FST gene therapy were protected from post-traumatic OA and bone remodeling induced by joint injury. Together, these findings suggest that FST gene therapy may provide a multifactorial therapeutic approach for injury-induced OA and metabolic inflammation in obesity

    Magnetothermopower and Magnetoresistivity of RuSr2Gd1-xLaxCu2O8 (x=0, 0.1)

    Full text link
    We report measurements of magnetothermopower and magnetoresistivity as a function of temperature on RuSr2Gd1-xLaxCu2O8 (x = 0, 0.1). The normal-state thermopower shows a dramatic decrease after applying a magnetic field of 5 T, whereas the resistivity shows only a small change after applying the same field. Our results suggest that RuO2 layers are conducting and the magnetic field induced decrease of the overall thermopower is caused by the decrease of partial thermopower decrease associated with the spin entropy decrease of the carriers in the RuO2 layers.Comment: 21 pages, 6 figure
    • 

    corecore