2,570 research outputs found

    Penrose-Onsager Criterion Validation in a One-Dimensional Polariton Condensate

    Get PDF
    We perform quantum tomography on one-dimensional polariton condensates, spontaneously occurring in linear disorder valleys in a CdTe planar microcavity sample. By the use of optical interferometric techniques, we determine the first-order coherence function and the amplitude and phase of the order parameter of the condensate, providing a full reconstruction of the single particle density matrix for the polariton system. The experimental data are used as input to theoretically test the consistency of Penrose-Onsager criterion for Bose-Einstein condensation in the framework of nonequilibrium polariton condensates. The results confirm the pertinence and validity of the criterion for a non equilibrium condensed gas.Comment: 5 pages, 4 figure

    Fine-scale spatial genetic structure in the frankincense tree Boswellia papyrifera (Del.) Hochst. and implications for conservation

    Get PDF
    The fine-scale genetic structure and how it varies between generations depends on the spatial scale of gene dispersal and other fundamental aspects of species’ biology, such as the mating system. Such knowledge is crucial for the design of genetic conservation strategies. This is particularly relevant for species that are increasingly fragmented such as Boswellia papyrifera. This species occurs in dry tropical forests from Ethiopia, Eritrea and Sudan and is an important source of frankincense, a highly valued aromatic resin obtained from the bark of the tree. This study assessed the genetic diversity and fine-scale spatial genetic structure (FSGS) of two cohorts (adults and seedlings) from two populations (Guba-Arenja and Kurmuk) in Western Ethiopia and inferred intra-population gene dispersal in the species, using microsatellite markers. The expected heterozygosity (HE) was 0.664–0.724. The spatial analyses based on kinship coefficient (Fij) revealed a significant positive genetic correlation up to a distance of 130 m. Spatial genetic structure was relatively weak (Sp = 0.002–0.014) indicating that gene dispersal is extensive within the populations. Based on the FSGS patterns found, we estimate indirectly gene dispersal distances of 103 and 124 m for the two populations studied. The high heterozygosity, the low fixation index and the low Sp values found in this study are consistent with outcrossing as the (predominant) mating system in B. papyrifera. We suggest that seed collection for ex situ conservation and reforestation programmes of B. papyrifera should use trees separated by distances of at least 100 m but preferably 150 m to limit genetic relatedness among seeds from different trees

    Three-Fluid Description of the Sympathetic Cooling of a Boson-Fermion Mixture

    Full text link
    We present a model for sympathetic cooling of a mixture of fermionic and bosonic atomic gases in harmonic traps, based on a three-fluid description. The model confirms the experimentally observed cooling limit of about 0.2 T_F when only bosons are pumped. We propose sequential cooling -- first pumping of bosons and afterwards fermions -- as a way to obtain lower temperatures. For this scheme, our model predicts that temperatures less than 0.1 T_F can be reached.Comment: 9 pages, 6 figure

    Aprotinin reduces cardiac troponin I release and inhibits apoptosis of polymorphonuclear cells during off-pump coronary artery bypass surgery

    Get PDF
    Objectives: In addition to blood-sparing effects, aprotinin may have cardioprotective and anti-inflammatory effects during cardiopulmonary bypass-assisted cardiac surgery. In this study, the authors examined whether aprotinin had cardioprotective and/or anti-inflammatory effects in patients undergoing off-pump coronary artery bypass grafting. Design: A prospective randomized clinical trial. Setting: University hospital. Participants: Fifty patients were randomized to control (n = 25) or aprotinin treatment (n = 25) groups. Interventions: Aprotinin was given as a loading dose (2 x 10(6) KIU) followed by a continuous infusion at 5 x 10(5) KIU/h until skin closure. Measurements and Main Results: Blood samples for cardiac troponin I; interleukin-6, interleukin-8, and interleukin-10; tumor necrosis factor a; and elastase were taken after anesthesia induction, completion of revascularization, and 6 hours, 12 hours, and 24 hours after revascularization. Blood samples were taken to assess for apoptosis in polymorphonuclear cells. Baseline plasma levels for cardiac troponin I did not differ between groups but were significantly lower in aprotinin-treated patients at the time of revascularization (P = 0.03) and 6 hours (p = 0.004) and 24 hours (p = 0.03) later. Aprotinin significantly reduced apoptosis in polymorphonuclear cells compared with control-treated patients (p = 0.04). There were no differences in plasma cytokine or elastase levels between groups. Conclusions: The authors conclude that aprotinin reduces perioperative cardiac troponin I release and attenuates apoptosis in polymorphonuclear cells but has no significant effects on plasma cytokine levels in patients undergoing off-pump coronary artery bypass graft surgery

    Intra-assessor reliability and measurement error of ultrasound measures for foot muscle morphology in older adults using a tablet-based ultrasound machine

    Get PDF
    BACKGROUND: To gain insight into the role of plantar intrinsic foot muscles in fall-related gait parameters in older adults, it is fundamental to assess foot muscles separately. Ultrasonography is considered a promising instrument to quantify the strength capacity of individual muscles by assessing their morphology. The main goal of this study was to investigate the intra-assessor reliability and measurement error for ultrasound measures for the morphology of selected foot muscles and the plantar fascia in older adults using a tablet-based device. The secondary aim was to compare the measurement error between older and younger adults and between two different ultrasound machines. METHODS: Ultrasound images of selected foot muscles and the plantar fascia were collected in younger and older adults by a single operator, intensively trained in scanning the foot muscles, on two occasions, 1–8 days apart, using a tablet-based and a mainframe system. The intra-assessor reliability and standard error of measurement for the cross-sectional area and/or thickness were assessed by analysis of variance. The error variance was statistically compared across age groups and machines. RESULTS: Eighteen physically active older adults (mean age 73.8 (SD: 4.9) years) and ten younger adults (mean age 21.9 (SD: 1.8) years) participated in the study. In older adults, the standard error of measurement ranged from 2.8 to 11.9%. The ICC ranged from 0.57 to 0.97, but was excellent in most cases. The error variance for six morphology measures was statistically smaller in younger adults, but was small in older adults as well. When different error variances were observed across machines, overall, the tablet-based device showed superior repeatability. CONCLUSIONS: This intra-assessor reliability study showed that a tablet-based ultrasound machine can be reliably used to assess the morphology of selected foot muscles in older adults, with the exception of plantar fascia thickness. Although the measurement errors were sometimes smaller in younger adults, they seem adequate in older adults to detect group mean hypertrophy as a response to training. A tablet-based ultrasound device seems to be a reliable alternative to a mainframe system. This advocates its use when foot muscle morphology in older adults is of interest. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13047-022-00510-1

    The effect of interventions anticipated to improve plantar intrinsic foot muscle strength on fall-related dynamic function in adults:A systematic review

    Get PDF
    BACKGROUND: The plantar intrinsic foot muscles (PIFMs) have a role in dynamic functions, such as balance and propulsion, which are vital to walking. These muscles atrophy in older adults and therefore this population, which is at high risk to falling, may benefit from strengthening these muscles in order to improve or retain their gait performance. Therefore, the aim was to provide insight in the evidence for the effect of interventions anticipated to improve PIFM strength on dynamic balance control and foot function during gait in adults. METHODS: A systematic literature search was performed in five electronic databases. The eligibility of peer-reviewed papers, published between January 1, 2010 and July 8, 2020, reporting controlled trials and pre-post interventional studies was assessed by two reviewers independently. Results from moderate- and high-quality studies were extracted for data synthesis by summarizing the standardized mean differences (SMD). The GRADE approach was used to assess the certainty of evidence. RESULTS: Screening of 9199 records resulted in the inclusion of 11 articles of which five were included for data synthesis. Included studies were mainly performed in younger populations. Low-certainty evidence revealed the beneficial effect of PIFM strengthening exercises on vertical ground reaction force (SMD: − 0.31-0.37). Very low-certainty evidence showed that PIFM strength training improved the performance on dynamic balance testing (SMD: 0.41–1.43). There was no evidence for the effect of PIFM strengthening exercises on medial longitudinal foot arch kinematics. CONCLUSIONS: This review revealed at best low-certainty evidence that PIFM strengthening exercises improve foot function during gait and very low-certainty evidence for its favorable effect on dynamic balance control. There is a need for high-quality studies that aim to investigate the effect of functional PIFM strengthening exercises in large samples of older adults. The outcome measures should be related to both fall risk and the role of the PIFMs such as propulsive forces and balance during locomotion in addition to PIFM strength measures. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13047-021-00509-0

    Bose-Einstein condensation of Efimovian triples in the unitary Bose gas

    Get PDF
    In an atomic Bose-Einstein condensate quenched to the unitary regime, we predict the sequential formation of a significant fraction of condensed pairs and triples. At short-distances, we demonstrate the two-body and Efimovian character of the condensed pairs and triples, respectively. As the system evolves, the size of the condensed pairs and triples becomes comparable to the interparticle distance, such that many-body effects become significant. The structure of the condensed triples depends on the relative size of Efimov states to density scales. Unexpectedly, we find universal condensed triples in the limit where these scales are well-separated. Our findings provide a new framework for understanding dynamics in the unitary regime as the Bose-Einstein condensation of few-body composites

    Spin measurements for 147Sm+n resonances: Further evidence for non-statistical effects

    Full text link
    We have determined the spins J of resonances in the 147Sm(n,gamma) reaction by measuring multiplicities of gamma-ray cascades following neutron capture. Using this technique, we were able to determine J values for all but 14 of the 140 known resonances below En = 1 keV, including 41 firm J assignments for resonances whose spins previously were either unknown or tentative. These new spin assignments, together with previously determined resonance parameters, allowed us to extract separate level spacings and neutron strength functions for J = 3 and 4 resonances. Furthermore, several statistical test of the data indicate that very few resonances of either spin have been missed below En = 700eV. Because a non-statistical effect recently was reported near En = 350 eV from an analysis of 147Sm(n,alpha) data, we divided the data into two regions; 0 < En < 350 eV and 350 < En < 700 eV. Using neutron widths from a previous measurement and published techniques for correcting for missed resonances and for testing whether data are consistent with a Porter-Thomas distribution, we found that the reduced-neutron-width distribution for resonances below 350 eV is consistent with the expected Porter-Thomas distribution. On the other hand, we found that reduced-neutron-width data in the 350 < En < 700 eV region are inconsistent with a Porter-Thomas distribution, but in good agreement with a chi-squared distribution having two or more degrees of freedom. We discuss possible explanations for these observed non-statistical effects and their possible relation to similar effects previously observed in other nuclides.Comment: 40 pages, 13 figures, accepted by Phys. Rev.

    Direct magneto-optical compression of an effusive atomic beam for high-resolution focused ion beam application

    Get PDF
    An atomic rubidium beam formed in a 70 mm long two-dimensional magneto-optical trap (2D MOT), directly loaded from a collimated Knudsen source, is analyzed using laser-induced fluorescence. The longitudinal velocity distribution, the transverse temperature and the flux of the atomic beam are reported. The equivalent transverse reduced brightness of an ion beam with similar properties as the atomic beam is calculated because the beam is developed to be photoionized and applied in a focused ion beam. In a single two-dimensional magneto-optical trapping step an equivalent transverse reduced brightness of (1.0+0.8−0.4)(1.0\substack{+0.8-0.4}) ×106\times 10^6 A/(m2^2 sr eV) was achieved with a beam flux equivalent to (0.6+0.3−0.2)(0.6\substack{+0.3-0.2}) nA. The temperature of the beam is further reduced with an optical molasses after the 2D MOT. This increased the equivalent brightness to (6+5−2)(6\substack{+5-2})×106\times 10^6 A/(m2^2 sr eV). For currents below 10 pA, for which disorder-induced heating can be suppressed, this number is also a good estimate of the ion beam brightness that can be expected. Such an ion beam brightness would be a six times improvement over the liquid metal ion source and could improve the resolution in focused ion beam nanofabrication.Comment: 10 pages, 8 figures, 1 tabl
    • 

    corecore