259 research outputs found

    Analysis of stratified and closely spaced jets exhausting into a crossflow

    Get PDF
    Procedures have been developed for determining the flow field about jets with velocity stratification exhausting into a crossflow. Jets with three different types of exit velocity stratification have been considered: (1) jets with a relatively high velocity core; (2) jets with a relatively low velocity core; and (3) jets originating from a vaned nozzle. The procedure developed for a jet originating from a high velocity core nozzle is to construct an equivalent nozzle having the same mass flow and thrust but having a uniform exit velocity profile. Calculations of the jet centerline and induced surface static pressures have been shown to be in good agreement with test data for a high velocity core nozzle. The equivalent ideal nozzle has also been shown to be a good representation for jets with a relatively low velocity core and for jets originating from a vaned nozzle in evaluating jet-induced flow fields. For the singular case of a low velocity core nozzle, namely a nozzle with a dead air core, and for the vaned nozzle, an alternative procedure has been developed. The internal mixing which takes place in the jet core has been properly accounted for in the equations of motion governing the jet development. Calculations of jet centerlines and induced surface static pressures show good agreement with test data these nozzles

    Aromaticity as a Guiding Concept for Spectroscopic Features and Nonlinear Optical Properties of Porphyrinoids

    Get PDF
    With their versatile molecular topology and aromaticity, porphyrinoid systems combine remarkable chemistry with interesting photophysical properties and nonlinear optical properties. Hence, the field of application of porphyrinoids is very broad ranging from near-infrared dyes to opto-electronic materials. From previous experimental studies, aromaticity emerges as an important concept in determining the photophysical properties and two-photon absorption cross sections of porphyrinoids. Despite a considerable number of studies on porphyrinoids, few investigate the relationship between aromaticity, UV/vis absorption spectra and nonlinear properties. To assess such structure-property relationships, we performed a computational study focusing on a series of Hückel porphyrinoids to: (i) assess their (anti)aromatic character; (ii) determine the fingerprints of aromaticity on the UV/vis spectra; (iii) evaluate the role of aromaticity on the NLO properties. Using an extensive set of aromaticity descriptors based on energetic, magnetic, structural, reactivity and electronic criteria, the aromaticity of [4n+2] π-electron porphyrinoids was evidenced as was the antiaromaticity for [4n] π-electron systems. In agreement with previous studies, the absorption spectra of aromatic systems display more intense B and Q bands in comparison to their antiaromatic homologues. The nature of these absorption bands was analyzed in detail in terms of polarization, intensity, splitting and composition. Finally, quantities such as the average polarizability and its anisotropy were found to be larger in aromatic systems, whereas first and second hyperpolarizability are influenced by the interplay between aromaticity, planarity and molecular symmetry. To conclude, aromaticity dictates the photophysical properties in porphyrinoids, whereas it is not the only factor determining the magnitude of NLO properties

    Predicting postoperative troponin in patients undergoing elective hip or knee arthroplasty: A comparison of five cardiac risk prediction tools

    Get PDF
    BACKGROUND: Elderly patients undergoing hip or knee arthroplasty are at a risk for myocardial injury after noncardiac surgery (MINS). We evaluated the ability of five common cardiac risk scores, alone or combined with baseline high-sensitivity cardiac troponin I (hs-cTnI), in predicting MINS and postoperative day 2 (POD2) hs-cTnI levels in patients undergoing elective total hip or knee arthroplasty. METHODS: This study is ancillary to the Genetics-InFormatics Trial (GIFT) of Warfarin Therapy to Prevent Deep Venous Thrombosis, which enrolled patients 65 years and older undergoing elective total hip or knee arthroplasty. The five cardiac risk scores evaluated were the atherosclerotic cardiovascular disease calculator (ASCVD), the Framingham risk score (FRS), the American College of Surgeon\u27s National Surgical Quality Improvement Program (ACS-NSQIP) calculator, the revised cardiac risk index (RCRI), and the reconstructed RCRI (R-RCRI). RESULTS: None of the scores predicted MINS in women. Among men, the ASCVD ( CONCLUSION: In elderly patients undergoing elective hip or knee arthroplasty, several of the scores modestly predicted MINS in men and correlated with POD2 hs-cTnI

    A Precision Measurement of pp Elastic Scattering Cross Sections at Intermediate Energies

    Get PDF
    We have measured differential cross sections for \pp elastic scattering with internal fiber targets in the recirculating beam of the proton synchrotron COSY. Measurements were made continuously during acceleration for projectile kinetic energies between 0.23 and 2.59 GeV in the angular range 30θc.m.9030 \leq \theta_{c.m.} \leq 90 deg. Details of the apparatus and the data analysis are given and the resulting excitation functions and angular distributions presented. The precision of each data point is typically better than 4%, and a relative normalization uncertainty of only 2.5% within an excitation function has been reached. The impact on phase shift analysis as well as upper bounds on possible resonant contributions in lower partial waves are discussed.Comment: 23 pages 29 figure

    Antithrombotic Therapy in Patients with Acute Coronary Syndrome in the Intermountain Heart Collaborative Study

    Get PDF
    Objective. To determine factors associated with single antiplatelet (SAP) or dual antiplatelet (DAP) therapy and anticoagulants (AC) use in hospital and after discharge among patients with acute coronary syndrome (ACS). Methods. We evaluated 5,294 ACS patients in the Intermountain Heart Collaborative Study from 2004 to 2009. Multivariable logistic regressions were used to determine predictors of AC or AP use. Results. In hospital, 99% received an AC, 79% DAP, and 19% SAP; 78% had DAP + AC. Coronary stents were the strongest predictors of DAP use in hospital compared to SAP (P<0.001). After discharge, 77% received DAP, 20% SAP, and 9% AC; 5% had DAP + AC. DAP compared to SAP was less likely for patients on AC (odds ratio [OR] = 0.30, P<0.0001) after discharge. Placement of a stent increased the likelihood of DAP (bare metal: OR = 54.8, P<0.0001; drug eluting: OR = 59.4, P<0.0001). 923 had atrial fibrillation and 337 had a history of venous thromboembolism; these patients had increased use of AC (29% and 40%, resp.). Conclusion. While in-hospital use of AC was nearly universal, postdischarge AC use was rare. Concern for providing the best antithrombotic therapy, while maintaining an acceptable bleeding risk, may explain the selection decisions

    Deriving the number of jobs in proximity services from the number of inhabitants in French rural municipalities

    Get PDF
    We use a minimum requirement approach to derive the number of jobs in proximity services per inhabitant in French rural municipalities. We first classify the municipalities according to their time distance to the municipality where the inhabitants go the most frequently to get services (called MFM). For each set corresponding to a range of time distance to MFM, we perform a quantile regression estimating the minimum number of service jobs per inhabitant, that we interpret as an estimation of the number of proximity jobs per inhabitant. We observe that the minimum number of service jobs per inhabitant is smaller in small municipalities. Moreover, for municipalities of similar sizes, when the distance to the MFM increases, we find that the number of jobs of proximity services per inhabitant increases.Comment: 6 pages, 5 figure

    OGLE-2005-BLG-153: Microlensing Discovery and Characterization of A Very Low Mass Binary

    Get PDF
    The mass function and statistics of binaries provide important diagnostics of the star formation process. Despite this importance, the mass function at low masses remains poorly known due to observational difficulties caused by the faintness of the objects. Here we report the microlensing discovery and characterization of a binary lens composed of very low-mass stars just above the hydrogen-burning limit. From the combined measurements of the Einstein radius and microlens parallax, we measure the masses of the binary components of 0.10±0.01 M0.10\pm 0.01\ M_\odot and 0.09±0.01 M0.09\pm 0.01\ M_\odot. This discovery demonstrates that microlensing will provide a method to measure the mass function of all Galactic populations of very low mass binaries that is independent of the biases caused by the luminosity of the population.Comment: 6 pages, 3 figures, 1 tabl

    OGLE-2005-BLG-018: Characterization of Full Physical and Orbital Parameters of a Gravitational Binary Lens

    Get PDF
    We present the analysis result of a gravitational binary-lensing event OGLE-2005-BLG-018. The light curve of the event is characterized by 2 adjacent strong features and a single weak feature separated from the strong features. The light curve exhibits noticeable deviations from the best-fit model based on standard binary parameters. To explain the deviation, we test models including various higher-order effects of the motions of the observer, source, and lens. From this, we find that it is necessary to account for the orbital motion of the lens in describing the light curve. From modeling of the light curve considering the parallax effect and Keplerian orbital motion, we are able to measure not only the physical parameters but also a complete orbital solution of the lens system. It is found that the event was produced by a binary lens located in the Galactic bulge with a distance 6.7±0.36.7\pm 0.3 kpc from the Earth. The individual lens components with masses 0.9±0.3 M0.9\pm 0.3\ M_\odot and 0.5±0.1 M0.5\pm 0.1\ M_\odot are separated with a semi-major axis of a=2.5±1.0a=2.5 \pm 1.0 AU and orbiting each other with a period P=3.1±1.3P=3.1 \pm 1.3 yr. The event demonstrates that it is possible to extract detailed information about binary lens systems from well-resolved lensing light curves.Comment: 19 pages, 6 figure

    Observation of a Coherence Length Effect in Exclusive Rho^0 Electroproduction

    Get PDF
    Exclusive incoherent electroproduction of the rho^0(770) meson from 1H, 2H, 3He, and 14N targets has been studied by the HERMES experiment at squared four-momentum transfer Q**2>0.4 GeV**2 and positron energy loss nu from 9 to 20 GeV. The ratio of the 14N to 1H cross sections per nucleon, known as the nuclear transparency, was found to decrease with increasing coherence length of quark-antiquark fluctuations of the virtual photon. The data provide clear evidence of the interaction of the quark- antiquark fluctuations with the nuclear medium.Comment: RevTeX, 5 pages, 3 figure

    Measurement of the Spin Asymmetry in the Photoproduction of Pairs of High-pT Hadrons at HERMES

    Get PDF
    We present a measurement of the longitudinal spin asymmetry A_|| in photoproduction of pairs of hadrons with high transverse momentum p_T. Data were accumulated by the HERMES experiment using a 27.5 GeV polarized positron beam and a polarized hydrogen target internal to the HERA storage ring. For h+h- pairs with p_T^h_1 > 1.5 GeV/c and p_T^h_2 > 1.0 GeV/c, the measured asymmetry is A_|| = -0.28 +/- 0.12 (stat.) +/- 0.02 (syst.). This negative value is in contrast to the positive asymmetries typically measured in deep inelastic scattering from protons, and is interpreted to arise from a positive gluon polarization.Comment: 5 pages (latex), 4 figures (eps
    corecore