    Suitable Electrode Choice for Robotic-Assisted Cochlear Implant Surgery: A Systematic Literature Review of Manual Electrode Insertion Adverse Events

    Get PDF
    BACKGROUND AND OBJECTIVE: The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. METHODS: A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. RESULTS: A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4–6.6%) of ETFO, 28.6% (26.6–30.6%) of ESD, and 0.53% (0.2–1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1–1.3%), 11% (9.2–13.0%), and 3.2% (2.5–3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. CONCLUSION: Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications

    Sustained release of triamcinolone acetonide from an intratympanically applied hydrogel designed for the delivery of high glucocorticoid doses

    No full text
    The pharmacokinetic properties and tolerability of a triamcinolone acetonide poloxamer 407 hydrogel for intratympanic application were investigated in a guinea pig model. Evaluation of in vivo release kinetics showed very high initial perilymph drug levels, with clinically relevant levels present for a minimum of 10 days. Assessment of auditory brainstem response thresholds showed a minimal, delayed and transient threshold shift, which was apparent on day 3 and resolved by day 10. No relevant histological changes of the middle and inner ear structures were noted, and hair cell counts showed no significant differences between treated and untreated ears. Thus, the triamcinolone-acetonide-loaded poloxamer 407 hydrogel is an effective vehicle for sustained high-dose inner ear glucocorticoid delivery

    Combined electric acoustic stimulation with the PULSARCI(100) implant system using the FLEX(EAS) electrode array

    No full text
    This study demonstrates that electric acoustic stimulation (EAS(®)) using the FLEX(EAS) electrode is a successful treatment method for preservation and stability of low frequency hearing, and results in significant improvements in speech perception

    Wiener klinische Wochenschrift / Identification of a rare COCH mutation by whole-exome sequencing : Implications for personalized therapeutic rehabilitation in an Austrian family with non-syndromic autosomal dominant late-onset hearing loss

    No full text
    Background Non-syndromic autosomal dominant hearing impairment is characteristically postlingual in onset. Genetic diagnostics are essential for genetic counselling, disease prognosis and understanding of the molecular mechanisms of disease. To date, 36 causative genes have been identified, many in only individual families. Gene selection for genetic screening by traditional methods and genetic diagnosis in autosomal dominant patients has therefore been fraught with difficulty. Whole-exome sequencing provides a powerful tool to analyze all protein-coding genomic regions in parallel, thus allowing the comprehensive screening of all known genes and associated alterations. Methods In this study, a previously undiagnosed late-onset progressive autosomal dominant hearing loss in an Austrian family was investigated by means of whole-exome sequencing. Results were confirmed by Sanger sequencing. Results A previously described c.151C>T missense (p.Pro51Ser) mutation in the LCCL (limulus factor C, cochlin, late gestation lung protein Lgl1) domain of the cochlin gene (COCH) was identified as causative and segregated with disease in five members of the family. Molecular diagnostics led to the decision to perform cochlear implantation in an index patient who subsequently showed excellent postoperative auditory performance. The c.151C>T mutation was not found in 18 screened Austrian families with autosomal dominant hearing loss but was represented alongside other known pathogenic mutant COCH alleles in the Genome Aggregation Database (gnomAD) in European populations. A combined allele frequency of 0.000128 implies an orphan disease frequency for COCH-induced hearing loss of 1:3900 in Europe. Conclusions Exome sequencing successfully resolved the genetic diagnosis in a family suffering from autosomal dominant hearing impairment and allowed prediction of purported auditory outcome after cochlear implantation in an index patient. Personalized treatment approaches based on the molecular mechanisms of disease may become increasingly important in the future.(VLID)358224

    The Laryngoscope / Long-term outcome of hearing rehabilitation with an active middle ear implant

    No full text
    Objective To assess the audiological and longterm medical and technical followup outcomes of an active middle ear implant. Methods This was a retrospective medical chart analysis of all patients provided with an active middle ear implant in a tertiary academic medical referral center between September 1, 1998, and July 31, 2015. Main outcome measures were medical and technical complications, revisions, reimplantations, explantations, coupling approaches, mean time of use, pre and postoperative hearing thresholds, functional hearing gain across frequencies (2504,000 Hz), and Freiburg monosyllablic word test at 65 dB. Results One hundred and three patients were identified. Fifteen were implanted bilaterally (n = 118 Vibrant Soundbridge devices [MEDEL, Innsbruck, Austria]). Seventyseven devices were implanted for sensorineural and 41 for mixed and conductive hearing loss. Patients used the implant for 6.7 years (range 0.7 months17.9 years) on average. Ninetyone patients (77.12%) were using the device at the end of the observation period. An overall complication rate of 16.1% was observed. The revision and explantation rates were higher for devices implanted between 2004 and 2006. The device failure rate was 3.4%. Audiological evaluation showed significant hearing gains for both hearing loss patient groups. Conclusion This longterm followup reveals the reliability of the active middle ear implant in a single center. Overall complication rate and device failure rate are acceptable. The complication rate was higher during implementation of alternative coupling approaches. The audiological benefit was satisfactory in patients with all hearing loss types. The majority of implanted patients used the implant at the end of the observation period.(VLID)341189

    Long-Term Outcome and Comparison of Treatment Modalities of Temporal Bone Paragangliomas

    No full text
    Introduction: Temporal bone paragangliomas are rare tumors with high vascularization and usually benign entity. A variety of modalities, including gross total resection, subtotal resection, conventional or stereotactic radiotherapy including gamma-knife, embolization, and wait-and-scan strategy can be considered. The aim of this study was to compare long-term outcomes of different primary treatment modalities in temporal bone paragangliomas. Materials and Methods: Patients with temporal bone paragangliomas treated between 1976 and 2018 at a tertiary referral center were retrospectively analyzed in this study. Collected patient data of 42 years were analyzed and long-term results including interdisciplinary management were assessed. Patient outcomes were compared within the different therapy modalities according to tumor control rate and complications. Clinical characteristics, radiological imaging, tumor extent and location (according to Fisch classification), symptoms, and follow-up were evaluated and a descriptive analysis for each treatment modality was performed. Tumor recurrence or growth progression and respective cranial nerve function before and after therapy were described. Results: A total of 59 patients were treated with a single or combined treatment modality and clinical follow-up was 7 (13) years (median, interquartile range). Of the included patients 45 (76%) were female and 14 (24%) male (ratio 3:1) with a patient age range from 18 to 83 years. Total resection was performed on 31 patients, while 14 patients underwent subtotal resection. Eleven patients were treated with conventional primary radiotherapy or gamma-knife radiosurgery. Pulsatile tinnitus (n = 17, 29%) and hearing impairment (n = 16, 27%) were the most common symptoms in our patient group. Permanent lower cranial nerve deficits were observed only in patients with large tumors (Fisch C and D, n = 14, 24%). Among the 45 patients who were treated surgically, 88% of patients with Fisch A and B paragangliomas had no recurrent disease, while no tumor growth was perceived in 83% of patients with Fisch C and D paragangliomas. Conclusion: In conclusion, we propose surgery as a treatment option for patients with small tumors, due to a high control rate and less cranial nerve deficits compared to larger tumors. Although patients with Fisch C and D temporal bone paraganglioma can be treated surgically, only subtotal resections are possible in many cases. Additionally, frequent occurrence of cranial nerve deficits in those patients and tumor growth progression in long-term follow-up examinations make a combination of the therapy modalities or a primary radiotherapy more suitable in larger tumors