    Optimizing measurement of subjective amplitude of accommodation with defocus curves

    Get PDF
    PURPOSE: To determine whether letter sequences and/or lens-presentation order should be randomized when measuring defocus curves and to assess the most appropriate criterion for calculating the subjective amplitude of accommodation (AoA) from defocus curves. SETTING: Eye Clinic, School of Life & Health Sciences, Aston University, Birmingham, United Kingdom. METHODS: Defocus curves (from +3.00 diopters [D] to -3.00 D in 0.50 D steps) for 6 possible combinations of randomized or nonrandomized letter sequences and/or lens-presentation order were measured in a random order in 20 presbyopic subjects. Subjective AoA was calculated from the defocus curves by curve fitting using various published criteria, and each was correlated to subjective push-up AoA. Objective AoA was measured for comparison of blur tolerance and pupil size. RESULTS: Randomization of lens-presentation order and/or letter sequences, or lack of, did not affect the measured defocus curves (P>.05, analysis of variance). The range of defocus that maintains highest achievable visual acuity (allowing for variability of repeated measurement) was better correlated to (r = 0.84) and agreed best with ( 0.50 D) subjective push-up AoA than any other relative or absolute acuity criterion used in previous studies. CONCLUSIONS: Nonrandomized letters and lens presentation on their own did not affect subjective AoA measured by defocus curves, although their combination should be avoided. Quantification of subjective AoA from defocus curves should be standardized to the range of defocus that maintains the best achievable visual acuity

    Comparison of near visual acuity and reading metrics in presbyopia correction

    Get PDF
    PURPOSE: To provide a consistent standard for the evaluation of different types of presbyopic correction. SETTING: Eye Clinic, School of Life and Health Sciences, Aston University, Birmingham, United Kingdom. METHODS: Presbyopic corrections examined were accommodating intraocular lenses (IOLs), simultaneous multifocal and monovision contact lenses, and varifocal spectacles. Binocular near visual acuity measured with different optotypes (uppercase letters, lowercase letters, and words) and reading metrics assessed with the Minnesota Near Reading chart (reading acuity, critical print size [CPS], CPS reading speed) were intercorrelated (Pearson product moment correlations) and assessed for concordance (intraclass correlation coefficients [ICC]) and agreement (Bland-Altman analysis) for indication of clinical usefulness. RESULTS: Nineteen accommodating IOL cases, 40 simultaneous contact lens cases, and 38 varifocal spectacle cases were evaluated. Other than CPS reading speed, all near visual acuity and reading metrics correlated well with each other (r>0.70, P<.001). Near visual acuity measured with uppercase letters was highly concordant (ICC, 0.78) and in close agreement with lowercase letters (+/- 0.17 logMAR). Near word acuity agreed well with reading acuity (+/- 0.16 logMAR), which in turn agreed well with near visual acuity measured with uppercase letters 0.16 logMAR). Concordance (ICC, 0.18 to 0.46) and agreement (+/- 0.24 to 0.30 logMAR) of CPS with the other near metrics was moderate. CONCLUSION: Measurement of near visual ability in presbyopia should be standardized to include assessment of near visual acuity with logMAR uppercase-letter optotypes, smallest logMAR print size that maintains maximum reading speed (CPS), and reading speed. J Cataract Refract Surg 2009; 35:1401-1409 (C) 2009 ASCRS and ESCR

    The influence of corneoscleral topography on soft contact lens fit

    Get PDF
    To evaluate the influence of peripheral ocular topography, as evaluated by optical coherence tomography (OCT), compared with traditional measures of corneal profile using keratometry and videokeratoscopy, on soft contact lens fit

    An update on the characteristics of patients attending the Kooyong Low Vision Clinic

    Get PDF
    BACKGROUND: Since 1972, the Australian College of Optometry has worked in partnership with Vision Australia to provide multidisciplinary low-vision care at the Kooyong Low Vision Clinic. In 1999, Wolffsohn and Cochrane reported on the demographic characteristics of patients attending Kooyong. Sixteen years on, the aim of this study is to review the demographics of the Kooyong patient cohort and prescribing patterns. METHODS: Records of all new patients (n = 155) attending the Kooyong Low Vision Clinic for optometry services between April and September 2012 were retrospectively reviewed. RESULTS: Median age was 84.3 years (range 7.7 to 98.1 years) with 59 per cent female. The majority of patients presented with late-onset degenerative pathology, 49 per cent with a primary diagnosis of age-related macular degeneration. Many (47.1 per cent) lived with their families. Mean distance visual acuity was 0.57 ± 0.47 logMAR or approximately 6/24. The median spectacle-corrected near visual acuity was N8 (range N3 to worse than N80). Fifty patients (32.3 per cent) were prescribed new spectacles, 51 (32.9 per cent) low vision aids and five (8.3 per cent) were prescribed electronic magnification devices. Almost two-thirds (63.9 per cent) were referred for occupational therapy management and 12.3 per cent for orientation and mobility services. CONCLUSIONS: The profile of patients presenting for low-vision services at Kooyong is broadly similar to that identified in 1999. Outcomes appear to be similar, aside from an expected increase in electronic devices and technological solutions; however, the nature of services is changing, as treatments for ocular diseases advance and assistive technology develops and becomes more accessible. Alongside the aging population and age-related ocular disease being the predominant cause of low vision in Australia, the health-funding landscape is becoming more restrictive. The challenge for the future will be to provide timely, high-quality care in an economically efficient model

    Peripheral refraction validity of the Shin-Nippon SRW5000 autorefractor

    Get PDF
    PURPOSE: To investigate the operation of the Shin-Nippon/Grand Seiko autorefractor and whether higher-order aberrations affect its peripheral refraction measurements. METHODS: Information on instrument design, together with parameters and equations used to obtain refraction, was obtained from a patent. A model eye simulating the operating principles was tested with an optical design program. Effects of induced defocus and astigmatism on the retinal image were used to calibrate the model eye to match the patent equations. Coma and trefoil were added to assess their effects on the image. Peripheral refraction of a physical model eye was measured along four visual field meridians with the Shin-Nippon/Grand Seiko autorefractor SRW-5000 and a Hartmann-Shack aberrometer, and simulated autorefractor peripheral refraction was derived using the Zernike coefficients from the aberrometer. RESULTS: In simulation, the autorefractor's square image was changed in size by defocus, into rectangles or parallelograms by astigmatism, and into irregular shapes by coma and trefoil. In the presence of 1.0 D oblique astigmatism, errors in refraction were proportional to the higher-order aberrations, with up to 0.8 D sphere and 1.5 D cylinder for ±0.6 μm of coma or trefoil coefficients with a 5-mm-diameter pupil. For the physical model eye, refraction with the aberrometer was similar in all visual field meridians, but refraction with the autorefractor changed more quickly along one oblique meridian and less quickly along the other oblique meridian than along the horizontal and vertical meridians. Simulations predicted that higher-order aberrations would affect refraction in oblique meridians, and this was supported by the experimental measurements with the physical model eye. CONCLUSIONS: The autorefractor's peripheral refraction measurements are valid for horizontal and vertical field meridians, but not for oblique field meridians. Similar instruments must be validated before being adopted outside their design scope

    Rotational and centration stability of an aspheric intraocular lens with a simulated toric design

    Get PDF
    Purpose: To assess the stability of the Akreos AO intraocular lens (IOL) platform with a simulated toric design using objective image analysis. Setting: Six hospital eye clinics across Europe. Methods: After implantation in 1 eye of patients, IOLs with orientation marks were imaged at 1 to 2 days, 7 to 14 days, 30 to 60 days, and 120 to 180 days. The axis of rotation and IOL centration were objectively assessed using validated image analysis. Results: The study enrolled 107 patients with a mean age of 69.9 years ± 7.7 (SD). The image quality was sufficient for IOL rotation analysis in 91% of eyes. The mean rotation between the first day postoperatively and 120 to 180 days was 1.93 ± 2.33 degrees, with 96% of IOLs rotating fewer than 5 degrees and 99% rotating fewer than 10 degrees. There was no significant rotation between visits and no clear bias in the direction of rotation. In 71% of eyes, the dilation and image quality was sufficient for image analysis of centration. The mean change in centration between 1 day and 120 to 180 days was 0.21 ± 0.11 mm, with all IOLs decentering less than 0.5 mm. There was no significant decentration between visits and no clear bias in the direction of the decentration. Conclusion: Objective analysis of digital retroillumination images taken at different postoperative periods shows the aspheric IOL platform was stable in the eye and is therefore suitable for the application of a toric surface to correct corneal astigmatism

    Multifocal diffractive lens generating several fixed foci at different design wavelengths

    Get PDF
    We propose a method for designing multifocal diffractive lenses generating prescribed sets of foci with fixed positions at several different wavelengths. The method is based on minimizing the difference between the complex amplitudes of the beams generated by the lens microrelief at the design wavelengths, and the functions of the complex transmission of multifocal lenses calculated for these wavelengths. As an example, a zone plate generating three fixed foci at three different wavelengths was designed, fabricated, and experimentally investigated. The proof-of-concept experimental results confirm the formation of foci with fixed positions at the design wavelengths. The obtained results may find applications in the design and fabrication of novel multifocal contact and intraocular lenses with reduced chromatic effects

    An Italian translation and validation of the Near Activity Visual Questionnaire (NAVQ)

    Get PDF
    PURPOSE: To validate the Near Activity Vision Questionnaire (NAVQ) in Italian to allow the assessment of presbyopia corrections in Italian-speaking patients. METHODS: An Italian version of the NAVQ was arranged through several steps: an initial forward translation (from English to Italian), a backward translation (from Italian to English), and finally a consensual version to check against the original NAVQ. This prospective study enrolled native Italian-speaking presbyopic patients with corrected distance visual acuity of 0.20 logMAR or better in each eye and free of ocular anomalies. Six different groups of patients were asked to complete the questionnaire: emerging presbyopic patients, reading spectacle users, multifocal spectacle users, multifocal contact lens (CL) wearers, monovision CL wearers, and monofocal intraocular lens patients. Subjects were asked to answer the questionnaire again 2 weeks after the first completion. RESULTS: A total of 207 subjects completed the questionnaire. Data analysis showed good internal consistency (Cronbach α = 0.93) and factorial validity with only one factor explaining 62.0% of the variance. Test-retest reliability was extremely good (ICC = 0.92) as well as discriminatory power of the questionnaire's ability to discriminate between subjects with different forms of presbyopic correction. CONCLUSIONS: The Italian version of the NAVQ matches the properties of the original English version. It is a valid instrument to evaluate near activity visual quality of presbyopic Italian speakers

    The influence of end of day silicone hydrogel daily disposable contact lens fit on ocular comfort, physiology and lens wettability

    Get PDF
    Purpose: To quantify the end-of-day silicone-hydrogel daily disposable contact lens fit and its influence of on ocular comfort, physiology and lens wettability. Methods: Thirty-nine subjects (22.1. ±. 3.5 years) were randomised to wear each of 3 silicone-hydrogel daily-disposable contact lenses (narafilcon A, delefilcon A and filcon II 3), bilaterally, for one week. Lens fit was assessed objectively using a digital video slit-lamp at 8, 12 and 16. h after lens insertion. Hyperaemia, non-invasive tear break-up time, tear meniscus height and comfort were also evaluated at these timepoints, while corneal and conjunctival staining were assessed on lens removal. Results: Lens fit assessments were not different between brands (P > 0.05), with the exception of the movement at blink where narafilcon A was more mobile. Overall, lag reduced but push-up speed increased from 8 to 12. h (P 0.05). Movement-on-blink was unaffected by wear-time (F = 0.403, P = 0.670). A more mobile lens fit with one brand did not indicate that person would have a more mobile fit with another brand (r = -0.06 to 0.63). Lens fit was not correlated with comfort, ocular physiology or lens wettability (P > 0.01). Conclusions: Among the lenses tested, objective lens fit changed between 8. h and 12. h of lens wear. The weak correlation in individual lens fit between brands indicates that fit is dependent on more than ocular shape. Consequently, substitution of a different lens brand with similar parameters will not necessarily provide comparable lens fit
    • …