A high-precision polarimeter
We have built a polarimeter in order to measure the electron beam
polarization in hall C at JLAB. Using a superconducting solenoid to drive the
pure-iron target foil into saturation, and a symmetrical setup to detect the
Moller electrons in coincidence, we achieve an accuracy of <1%. This sets a new
standard for Moller polarimeters.Comment: 17 pages, 9 figures, submitted to N.I.
Recommended from our members
Modal response of interior mass based upon external measurements
Modal response testing has been used to predict the motion of interior masses of a system in which only external instrumentation is allowed. Testing of this form may occasionally be necessary in validation of a computer model, but also has potential as a tool for validating individual assemblies in a QA process. Examination of the external frequency response and mode shapes can offer insight into interior response. The interpretation of these results is improved through parallel analytical solutions. A simple, three-mass model has been examined experimentally and analytically to demonstrate modal theory. These results show the limitations of the external measurement in predicting internal response due to transmissibility. A procedure for utilizing external testing is described. The question posed through this research is whether or not modal correlation analysis can be adapted for use in systems for which instrumentation of critical components is missing
Adaptive servo-ventilation for central sleep apnea in heart failure
Background Central sleep apnea is associated with poor prognosis and death in patients with heart failure. Adaptive servo-ventilation is a therapy that uses a noninvasive ventilator to treat central sleep apnea by delivering servo-controlled inspiratory pressure support on top of expiratory positive airway pressure. We investigated the effects of adaptive servo-ventilation in patients who had heart failure with reduced ejection fraction and predominantly central sleep apnea. Methods We randomly assigned 1325 patients with a left ventricular ejection fraction of 45% or less, an apnea–hypopnea index (AHI) of 15 or more events (occurrences of apnea or hypopnea) per hour, and a predominance of central events to receive guideline-based medical treatment with adaptive servo-ventilation or guideline-based medical treatment alone (control). The primary end point in the time-to-event analysis was the first event of death from any cause, lifesaving cardiovascular intervention (cardiac transplantation, implantation of a ventricular assist device, resuscitation after sudden cardiac arrest, or appropriate lifesaving shock), or unplanned hospitalization for worsening heart failure. Results In the adaptive servo-ventilation group, the mean AHI at 12 months was 6.6 events per hour. The incidence of the primary end point did not differ significantly between the adaptive servo-ventilation group and the control group (54.1% and 50.8%, respectively; hazard ratio, 1.13; 95% confidence interval [CI], 0.97 to 1.31; P=0.10). All-cause mortality and cardiovascular mortality were significantly higher in the adaptive servo-ventilation group than in the control group (hazard ratio for death from any cause, 1.28; 95% CI, 1.06 to 1.55; P=0.01; and hazard ratio for cardiovascular death, 1.34; 95% CI, 1.09 to 1.65; P=0.006). Conclusions Adaptive servo-ventilation had no significant effect on the primary end point in patients who had heart failure with reduced ejection fraction and predominantly central sleep apnea, but all-cause and cardiovascular mortality were both increased with this therapy. (Funded by ResMed and others; SERVE-HF ClinicalTrials.gov number, NCT00733343. opens in new tab.
Final State Interaction Effects in pol 3He(pol e,e'p)
Asymmetries in quasi-elastic pol 3He(pol e,e'p) have been measured at a
momentum transfer of 0.67 (GeV/c)^2 and are compared to a calculation which
takes into account relativistic kinematics in the final state and a
relativistic one-body current operator. With an exact solution of the Faddeev
equation for the 3He-ground state and an approximate treatment of final state
interactions in the continuum good agreement is found with the experimental
data.Comment: 11 pages, 6 figures, submitted to Phys. Lett. B, revised version,
sensitivity study to relativity and NN-potential adde
Modelling Clock Synchronization in the Chess gMAC WSN Protocol
We present a detailled timed automata model of the clock synchronization
algorithm that is currently being used in a wireless sensor network (WSN) that
has been developed by the Dutch company Chess. Using the Uppaal model checker,
we establish that in certain cases a static, fully synchronized network may
eventually become unsynchronized if the current algorithm is used, even in a
setting with infinitesimal clock drifts
Impaired dynamic cerebral autoregulation in trained breath-hold divers
Breath-hold divers (BHD) experience repeated bouts of severe hypoxia and hypercapnia with large increases in blood pressure. However, the impact of long-term breath-hold diving on cerebrovascular control remains poorly understood. The ability of cerebral blood vessels to respond rapidly to changes in blood pressure represents the property of dynamic autoregulation. The current investigation tested the hypothesis that breathhold diving impairs dynamic autoregulation to a transient hypotensive stimulus. Seventeen BHD (3 women, 11 ± 9 yr of diving) and 15 healthy controls (2 women) completed two or three repeated sit-tostand trials during spontaneous breathing and poikilocapnic conditions. Heart rate (HR), finger arterial blood pressure (BP), and cerebral blood flow velocity (BFV) from the right middle cerebral artery were measured continuously with three-lead electrocardiography, finger photoplethysmography, and transcranial Doppler ultrasonography, respectively. End-tidal carbon dioxide partial pressure was measured with a gas analyzer. Offline, an index of cerebrovascular resistance (CVRi) was calculated as the quotient of mean BP and BFV. The rate of the drop in CVRi relative to the change in BP provided the rate of regulation [RoR; (δCVRi/δT)/δBP]. The BHD demonstrated slower RoR than controls (P ≤ 0.001, d = 1.4). Underlying the reduced RoR in BHD was a longer time to reach nadir CVRi compared with controls (P = 0.004, d = 1.1). In concert with the longer CVRi response, the time to reach peak BFV following standing was longer in BHD than controls (P = 0.01, d = 0.9). The data suggest impaired dynamic autoregulatory mechanisms to hypotension in BHD. NEW & NOTEWORTHY Impairments in dynamic cerebral autoregulation to hypotension are associated with breath-hold diving. Although weakened autoregulation was observed acutely in this group during apneic stress, we are the first to report on chronic adaptations in cerebral autoregulation. Impaired vasomotor responses underlie the reduced rate of regulation, wherein breath-hold divers demonstrate a prolonged dilatory response to transient hypotension. The slower cerebral vasodilation produces a longer perturbation in cerebral blood flow velocity, increasing the risk of cerebral ischemia
Are we missing the target? Are we aiming too low? What are the aerobic exercise prescriptions and their effects on markers of cardiovascular health and systemic inflammation in patients with knee osteoarthritis? A systematic review and meta-analysis
© Author(s) (or their employer(s)) 2020. No commercial re-use. See rights and permissions. Published by BMJ. Objectives We systemically reviewed published studies that evaluated aerobic exercise interventions in patients with knee osteoarthritis (OA) to: (1) report the frequency, intensity, type and time (FITT) of exercise prescriptions and (2) quantify the changes in markers of cardiovascular health and systemic inflammation. Data sources PubMed, CINAHL, Scopus; inception to January 2019. Eligibility criteria Randomised clinical trials (RCT), cohort studies, case series. Design We summarised exercise prescriptions for all studies and calculated effect sizes with 95% CIs for between-group (RCTs that compared exercise and control groups) and within-group (pre-post exercise) differences in aerobic capacity (VO 2), heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP) and inflammatory markers (interleukin-6 (IL-6), tumour necrosis factor-alpha). We pooled results where possible using random effects models. Results Interventions from 49 studies were summarised; 8% (4/49) met all FITT guidelines; 16% (8/49) met all or most FITT guidelines. Fourteen studies (10 RCTs) reported at least one marker of cardiovascular health or systemic inflammation. Mean differences (95% CI) indicated a small to moderate increase in VO 2 (0.84 mL/min/kg; 95% CI 0.37 to 1.31), decrease in HR (-3.56 beats per minute; 95% CI -5.60 to -1.52) and DBP (-4.10 mm Hg; 95% CI -4.82 to -3.38) and no change in SBP (-0.36 mm Hg; 95% CI -3.88 to 3.16) and IL-6 (0.37 pg/mL; 95% CI -0.11 to 0.85). Within-group differences were also small to moderate. Conclusions In studies of aerobic exercise in patients with knee OA, very few interventions met guideline-recommended dose; there were small to moderate changes in markers of cardiovascular health and no decrease in markers of systemic inflammation. These findings question whether aerobic exercise is being used to its full potential in patients with knee OA. PROSPERO registration number CRD42018087859
Measurement of the Electric Form Factor of the Neutron at Q^2=0.5 and 1.0 (GeV/c)^2
The electric form factor of the neutron was determined from measurements of
the \vec{d}(\vec{e},e' n)p reaction for quasielastic kinematics. Polarized
electrons were scattered off a polarized deuterated ammonia target in which the
deuteron polarization was perpendicular to the momentum transfer. The scattered
electrons were detected in a magnetic spectrometer in coincidence with neutrons
in a large solid angle detector. We find G_E^n = 0.0526 +/- 0.0033 (stat) +/-
0.0026 (sys) and 0.0454 +/- 0.0054 +/- 0.0037 at Q^2 = 0.5 and 1.0 (GeV/c)^2,
respectively.Comment: 5 pages, 2 figures, as publishe
- …