118 research outputs found

    Electron transport measurements in liquid xenon with Xenoscope, a large-scale DARWIN demonstrator

    Get PDF
    The DARWIN observatory is a proposed next-generation experiment with 40 tonnes of liquid xenon as an active target in a time projection chamber. To study challenges related to the construction and operation of a multi-tonne scale detector, we have designed and constructed a vertical, full-scale demonstrator for the DARWIN experiment at the University of Zurich. Here, we present the first results from a several-months run with 343kg of xenon and electron drift lifetime and transport measurements with a 53cm tall purity monitor immersed in the cryogenic liquid. After 88days of continuous purification, the electron lifetime reached a value of (664±23)μs. We measured the drift velocity of electrons for electric fields in the range (25–75) V/cm, and found values consistent with previous measurements. We also calculated the longitudinal diffusion constant of the electron cloud in the same field range, and compared with previous data, as well as with predictions from an empirical model

    Application and modeling of an online distillation method to reduce krypton and argon in XENON1T

    Full text link
    A novel online distillation technique was developed for the XENON1T dark matter experiment to reduce intrinsic background components more volatile than xenon, such as krypton or argon, while the detector was operating. The method is based on a continuous purification of the gaseous volume of the detector system using the XENON1T cryogenic distillation column. A krypton-in-xenon concentration of (360±60)ppq was achieved. It is the lowest concentration measured in the fiducial volume of an operating dark matter detector to date. A model was developed and fit to the data to describe the krypton evolution in the liquid and gas volumes of the detector system for several operation modes over the time span of 550 days, including the commissioning and science runs of XENON1T. The online distillation was also successfully applied to remove 37Ar after its injection for a low energy calibration in XENON1T. This makes the usage of 37Ar as a regular calibration source possible in the future. The online distillation can be applied to next-generation LXe TPC experiments to remove krypton prior to, or during, any science run. The model developed here allows further optimization of the distillation strategy for future large scale detectors

    Double-weak decays of 124Xe and 136Xe in the XENON1T and XENONnT experiments

    Full text link
    We present results on the search for two-neutrino double-electron capture (2νECEC) of 124Xe and neutrinoless double-β decay (0νββ) of 136Xe in XENON1T. We consider captures from the K shell up to the N shell in the 2νECEC signal model and measure a total half-life of T2νECEC1/2=(1.1±0.2stat±0.1sys)×1022yr with a 0.87kgyr isotope exposure. The statistical significance of the signal is 7.0σ. We use XENON1T data with 36.16kgyr of 136Xe exposure to search for 0νββ. We find no evidence of a signal and set a lower limit on the half-life of T0νββ1/2>1.2×1024yrat90%CL. This is the best result from a dark matter detector without an enriched target to date. We also report projections on the sensitivity of XENONnT to 0νββ. Assuming a 275kgyr 136Xe exposure, the expected sensitivity is T0νββ1/2>2.1×1025yrat90%CL, corresponding to an effective Majorana mass range of ⟨mββ⟩<(0.19–0.59)eV/c2

    Emission of single and few electrons in XENON1T and limits on light dark matter

    Full text link
    Delayed single- and few-electron emissions plague dual-phase time projection chambers, limiting their potential to search for light-mass dark matter. This paper examines the origins of these events in the XENON1T experiment. Characterization of the intensity of delayed electron backgrounds shows that the resulting emissions are correlated, in time and position, with high-energy events and can effectively be vetoed. In this work we extend previous S2-only analyses down to a single electron. From this analysis, after removing the correlated backgrounds, we observe rates <30 events/(electron×kg×day) in the region of interest spanning 1 to 5 electrons. We derive 90% confidence upper limits for dark matter-electron scattering, first direct limits on the electric dipole, magnetic dipole, and anapole interactions, and bosonic dark matter models, where we exclude new parameter space for dark photons and solar dark photons

    Low-energy Calibration of XENON1T with an Internal 37^{37}Ar Source

    Get PDF
    A low-energy electronic recoil calibration of XENON1T, a dual-phase xenontime projection chamber, with an internal 37^{37}Ar source was performed. Thiscalibration source features a 35-day half-life and provides two mono-energeticlines at 2.82 keV and 0.27 keV. The photon yield and electron yield at 2.82 keVare measured to be (32.3±\pm0.3) photons/keV and (40.6±\pm0.5) electrons/keV,respectively, in agreement with other measurements and with NEST predictions.The electron yield at 0.27 keV is also measured and it is(68.03.7+6.3^{+6.3}_{-3.7}) electrons/keV. The 37^{37}Ar calibration confirms thatthe detector is well-understood in the energy region close to the detectionthreshold, with the 2.82 keV line reconstructed at (2.83±\pm0.02) keV, whichfurther validates the model used to interpret the low-energy electronic recoilexcess previously reported by XENON1T. The ability to efficiently remove argonwith cryogenic distillation after the calibration proves that 37^{37}Ar can beconsidered as a regular calibration source for multi-tonne xenon detectors.<br

    Search for Coherent Elastic Scattering of Solar ⁸B Neutrinos in the XENON1T Dark Matter Experiment

    Get PDF
    We report on a search for nuclear recoil signals from solar 8B neutrinos elastically scattering off xenon nuclei in XENON1T data, lowering the energy threshold from 2.6 to 1.6  keV. We develop a variety of novel techniques to limit the resulting increase in backgrounds near the threshold. No significant 8B neutrinolike excess is found in an exposure of 0.6  t×y. For the first time, we use the nondetection of solar neutrinos to constrain the light yield from 1–2 keV nuclear recoils in liquid xenon, as well as nonstandard neutrino-quark interactions. Finally, we improve upon world-leading constraints on dark matter-nucleus interactions for dark matter masses between 3 and 11  GeV c−2 by as much as an order of magnitude

    Solar neutrino detection sensitivity in DARWIN via electron scattering

    Get PDF
    We detail the sensitivity of the proposed liquid xenon DARWIN observatory to solar neutrinos via elastic electron scattering. We find that DARWIN will have the potential to measure the fluxes of five solar neutrino components: pp, 7Be, 13N, 15O and pep. The precision of the 13N, 15O and pep components is hindered by the double-beta decay of 136Xe and, thus, would benefit from a depleted target. A high-statistics observation of pp neutrinos would allow us to infer the values of the electroweak mixing angle, sin 2θw, and the electron-type neutrino survival probability, Pee, in the electron recoil energy region from a few keV up to 200&nbsp;keV for the first time, with relative precision of 5% and 4%, respectively, with 10 live years of data and a 30&nbsp;tonne fiducial volume. An observation of pp and 7Be neutrinos would constrain the neutrino-inferred solar luminosity down to 0.2%. A combination of all flux measurements would distinguish between the high- (GS98) and low-metallicity (AGS09) solar models with 2.1–2.5σ significance, independent of external measurements from other experiments or a measurement of 8B neutrinos through coherent elastic neutrino-nucleus scattering in DARWIN. Finally, we demonstrate that with a depleted target DARWIN may be sensitive to the neutrino capture process of 131Xe

    Search for inelastic scattering of WIMP dark matter in XENON1T

    Get PDF
    We report the results of a search for the inelastic scattering of weakly interacting massive particles (WIMPs) in the XENON1T dark matter experiment. Scattering off 129Xe is the most sensitive probe of inelastic WIMP interactions, with a signature of a 39.6 keV deexcitation photon detected simultaneously with the nuclear recoil. Using an exposure of 0.83 tonne-years, we find no evidence of inelastic WIMP scattering with a significance of more than 2σ. A profile-likelihood ratio analysis is used to set upper limits on the cross section of WIMP-nucleus interactions. We exclude new parameter space for WIMPs heavier than 100  GeV/c2, with the strongest upper limit of 3.3×10−39  cm2 for 130  GeV/c2 WIMPs at 90% confidence level
    corecore