288 research outputs found
Fixed-angle plates in patella fractures - a pilot cadaver study
<p>Abstract</p> <p>Objective</p> <p>Modified anterior tension wiring with K-wires and cannulated lag screws with anterior tension wiring are currently the fixation of choice for patellar fractures. Failure of fixation, migration of the wires, postoperative pain and resulting revision surgery, however, are not uncommon. After preliminary biomechanical testing of a new fixed-angle plate system especially designed for fixation of patella fractures the aim of this study was to evaluate the surgical and anatomical feasibility of implanting such a plate-device at the human patella.</p> <p>Methods</p> <p>In six fresh unfixed female cadavers without history of previous fractures around the knee (average age 88.8 years) a bilateral fixed-angle plate fixation of the patella was carried out after previous placement of a transverse central osteotomy. Operative time, intra-operative problems, degree of retropatellar arthritis (following Outerbridge), quality of reduction and existence of any intraarticular screw placement have been raised. In addition, lateral and anteroposterior radiographs of all specimens were made.</p> <p>Results</p> <p>Due to the high average age of 88.8 years no patella showed an unimpaired retropatellar articular surface and all were severely osteoporotic, which made a secure fixation of the reduction forceps during surgery difficult. The operation time averaged 49 minutes (range: 36-65). Although in postoperative X-rays the fracture gap between the fragments was still visible, the analysis of the retropatellar surface showed no residual articular step or dehiscence > 0.5 mm. Also in a total of 24 inserted screws not one intraarticular malposition was found. No intraoperative complications were noticed.</p> <p>Conclusions</p> <p>Osteosynthesis of a medial third patella fracture with a bilateral fixed-angle plate-device is surgically and anatomically feasible without difficulties. Further studies have to depict whether the bilateral fixed-angle plate-osteosynthesis of the patella displays advantages over the established operative procedures.</p
Changes in union membership over time : a panel analysis for West Germany
Despite the apparent stability of the wage bargaining institutions in West Germany, aggregate union membership has been declining dramatically since the early 90's. However, aggregate gross membership numbers do not distinguish by employment status and it is impossible to disaggregate these sufficiently. This paper uses four waves of the German Socioeconomic Panel in 1985, 1989, 1993, and 1998 to perform a panel analysis of net union membership among employees. We estimate a correlated random effects probit model suggested in Chamberlain (1984) to take proper account of individual specfic effects. Our results suggest that at the individual level the propensity to be a union member has not changed considerably over time. Thus, the aggregate decline in membership is due to composition effects. We also use the estimates to predict net union density at the industry level based on the IAB employment subsample for the time period 1985 to 1997. JEL - Klassifikation: J
Repeatability of the three dimensional kinematics of the pelvis, spine and lower limbs while performing selected exercises
Three-dimensional optical systems are used for calculating many kinetic and kinematic parameters. The obtained data are precise; however, their repeatability is a very important aspect. The aim of this paper is to verify the range of motion repeatability of one healthy subject in the joints of the pelvis, spine and lower limbs based on the coefficient of variation. The participant performed seven exercises, repeated five times: two-leg squat, single-leg squat, forward bending, forward-step motion, step onto the stair, hip extension in a standing position and tip-toe extension while standing. Motion was recorded using Vicon motion capture system consisting of eight NIR cameras. The participant had 39 markers attached to her body according to the Plug-in Gait model. The coefficient of variation was calculated in three dimensions (X, Y and Z). The greatest repeatability, pursuant to the coefficient, was observed during the two-leg squat and forward bending in the sagittal plane (X coordinate). It was also high during the single-leg squat. The lowest repeatability was observed during the tip-toe extension while standing and the hip extension in a standing position. During the step onto the stair and the forward-step motion, a higher repeatability of measurement occurred in the open kinematic chain than in the closed chain; in the hip extension the reverse occurred. Repeatability of a range of motion is different in two types of kinematic chain and in 7 exercises. Exercises such as tip-toe extension and hip extension, which require a greater ability to balance, indicated more variability in movement
Changes in Union Membership Over Time : A Panel Analysis for West Germany
Despite the apparent stability of the wage bargaining institutions in West Germany, aggregate union membership has been declining dramatically since the early 90's. However, aggregate gross membership numbers do not distinguish by employment status and it is impossible to disaggregate these su±ciently. This paper uses four waves of the German Socioeconomic Panel in 1985, 1989, 1993, and 1998 to perform a panel analysis of net union membership among employees. We estimate a correlated random effects probit model suggested in Chamberlain (1984) to take proper account of individual specific effects. Our results suggest that at the individual level the propensity to be a union member has not changed considerably over time. Thus, the aggregate decline in membership is due to composition effects. We also use the estimates to predict net union density at the industry level based on the IAB employment subsample for the time period 1985 to 1997
Reinforcing the role of the conventional C-arm - a novel method for simplified distal interlocking
<p>Abstract</p> <p>Background</p> <p>The common practice for insertion of distal locking screws of intramedullary nails is a freehand technique under fluoroscopic control. The process is technically demanding, time-consuming and afflicted to considerable radiation exposure of the patient and the surgical personnel. A new concept is introduced utilizing information from within conventional radiographic images to help accurately guide the surgeon to place the interlocking bolt into the interlocking hole. The newly developed technique was compared to conventional freehand in an operating room (OR) like setting on human cadaveric lower legs in terms of operating time and radiation exposure.</p> <p>Methods</p> <p>The proposed concept (guided freehand), generally based on the freehand gold standard, additionally guides the surgeon by means of visible landmarks projected into the C-arm image. A computer program plans the correct drilling trajectory by processing the lens-shaped hole projections of the interlocking holes from a single image. Holes can be drilled by visually aligning the drill to the planned trajectory. Besides a conventional C-arm, no additional tracking or navigation equipment is required.</p> <p>Ten fresh frozen human below-knee specimens were instrumented with an Expert Tibial Nail (Synthes GmbH, Switzerland). The implants were distally locked by performing the newly proposed technique as well as the conventional freehand technique on each specimen. An orthopedic resident surgeon inserted four distal screws per procedure. Operating time, number of images and radiation time were recorded and statistically compared between interlocking techniques using non-parametric tests.</p> <p>Results</p> <p>A 58% reduction in number of taken images per screw was found for the guided freehand technique (7.4 ± 3.4) (mean ± SD) compared to the freehand technique (17.6 ± 10.3) (<it>p </it>< 0.001). Total radiation time (all 4 screws) was 55% lower for the guided freehand technique compared to conventional freehand (<it>p </it>= 0.001). Operating time per screw (from first shot to screw tightened) was on average 22% reduced by guided freehand (<it>p </it>= 0.018).</p> <p>Conclusions</p> <p>In an experimental setting, the newly developed guided freehand technique for distal interlocking has proven to markedly reduce radiation exposure when compared to the conventional freehand technique. The method utilizes established clinical workflows and does not require cost intensive add-on devices or extensive training. The underlying principle carries potential to assist implant positioning in numerous other applications within orthopedics and trauma from screw insertions to placement of plates, nails or prostheses.</p
The regional and global significance of nitrogen removal in lakes and reservoirs
Author Posting. © The Author(s), 2008. This is the author's version of the work. It is posted here by permission of Springer for personal use, not for redistribution. The definitive version was published in Biogeochemistry 93 (2009): 143-157, doi:10.1007/s10533-008-9272-x.Human activities have greatly increased the transport of biologically available N through
watersheds to potentially sensitive coastal ecosystems. Lentic water bodies (lakes and
reservoirs) have the potential to act as important sinks for this reactive N as it is
transported across the landscape because they offer ideal conditions for N burial in
sediments or permanent loss via denitrification. However, the patterns and controls on
lentic N removal have not been explored in great detail at large regional to global scales.
In this paper we describe, evaluate, and apply a new, spatially explicit, annual-scale,
global model of lentic N removal called NiRReLa (Nitrogen Retention in Reservoirs and
Lakes). The NiRReLa model incorporates small lakes and reservoirs than have been
included in previous global analyses, and also allows for separate treatment and analysis
of reservoirs and natural lakes. Model runs for the mid-1990s indicate that lentic systems
are indeed important sinks for N and are conservatively estimated to remove 19.7 Tg N
yr-1 from watersheds globally. Small lakes (< 50 km2) were critical in the analysis,
retaining almost half (9.3 Tg N yr-1) of the global total. In model runs, capacity of lakes
and reservoirs to remove watershed N varied substantially (0-100%) both as a function of
climate and the density of lentic systems. Although reservoirs occupy just 6% of the
global lentic surface area, we estimate they retain approximately 33% of the total N
removed by lentic systems, due to a combination of higher drainage ratios (catchment
surface area : lake or reservoir surface area), higher apparent settling velocities for N, and
greater N loading rates in reservoirs than in lakes. Finally, a sensitivity analysis of
NiRReLa suggests that, on-average, N removal within lentic systems will respond more
strongly to changes in land use and N loading than to changes in climate at the global
scale.The NSF26 Research Coordination Network on denitrification for support for collaboration
(award number DEB0443439 to S.P. Seitzinger and E.A. Davidson). This project was
also supported by grants to J.A. Harrison from California Sea Grant (award number
RSF8) and from the U.S. Geological Survey 104b program and R. Maranger (FQRNT
Strategic Professor)
- …