10 research outputs found

    Versailles Project on Advanced Materials and Standards interlaboratory study on intensity calibration for x-ray photoelectron spectroscopy instruments using low-density polyethylene

    Get PDF
    We report the results of a Versailles Project on Advanced Materials and Standards interlaboratory study on the intensity scale calibration of x-ray photoelectron spectrometers using low-density polyethylene (LDPE) as an alternative material to gold, silver, and copper. An improved set of LDPE reference spectra, corrected for different instrument geometries using a quartz-monochromated Al Kα x-ray source, was developed using data provided by participants in this study. Using these new reference spectra, a transmission function was calculated for each dataset that participants provided. When compared to a similar calibration procedure using the NPL reference spectra for gold, the LDPE intensity calibration method achieves an absolute offset of ∼3.0% and a systematic deviation of ±6.5% on average across all participants. For spectra recorded at high pass energies (≥90 eV), values of absolute offset and systematic deviation are ∼5.8% and ±5.7%, respectively, whereas for spectra collected at lower pass energies (<90 eV), values of absolute offset and systematic deviation are ∼4.9% and ±8.8%, respectively; low pass energy spectra perform worse than the global average, in terms of systematic deviations, due to diminished count rates and signal-to-noise ratio. Differences in absolute offset are attributed to the surface roughness of the LDPE induced by sample preparation. We further assess the usability of LDPE as a secondary reference material and comment on its performance in the presence of issues such as variable dark noise, x-ray warm up times, inaccuracy at low count rates, and underlying spectrometer problems. In response to participant feedback and the results of the study, we provide an updated LDPE intensity calibration protocol to address the issues highlighted in the interlaboratory study. We also comment on the lack of implementation of a consistent and traceable intensity calibration method across the community of x-ray photoelectron spectroscopy (XPS) users and, therefore, propose a route to achieving this with the assistance of instrument manufacturers, metrology laboratories, and experts leading to an international standard for XPS intensity scale calibration

    Bulk and surface conformations in solid-state lovastatin : Spectroscopic and molecular dynamics studies

    Get PDF
    Conformational flexibility in molecules can give rise to a range of functional group termi-nations at crystal surfaces and dynamic disorder in the bulk. In this work, we explore the confor-mational behavior of the drug molecule lovastatin in the crystallographically disordered solid and at crystal surfaces through a combination of computational modeling and spectroscopy. Gas-phase and periodic quantum-chemical calculations are used to study the potential energy surface associ-ated with rotatable bonds to examine the disorder in bulk. These calculations are combined with vibrational and X-ray photoelectron spectroscopy measurements to obtain insight into the conformations in bulk and at the surface. Our MD simulations show that the bulk disorder is driven by cooperative motion of the butyl group on the S-butanoate moiety along one crystallographic direc-tion beyond a unit cell. The calculations show that the O-H group can rotate relatively freely between two low-energy conformers in the gas phase but is locked in position by intermolecular H-bonding interactions in the bulk crystal, and we find tentative spectroscopic evidence for the second conformer being present at the surface. We also comment on the relative utility of these different techniques for studying molecular conformation in bulk and at surfaces and highlight possible areas for future developments
    corecore