287 research outputs found

    Progression of White Matter Lesion Volume and Health-Related Quality of Life in Patients with Symptomatic Atherosclerotic Disease: The SMART-MR Study

    Get PDF
    Objectives. Mechanisms influencing the course of physical and mental functioning after an atherosclerotic event are unclear. We examined effects of white matter lesion (WML) activity on changes in functioning in patients with symptomatic atherosclerotic disease. Methods. In 486 patients (58 ± 9 years) of the Second Manifestations of ARTerial disease-Magnetic Resonance (SMART-MR) study, volumetric WML measurements on 1.5T MRI were performed at baseline and 3.9 ± 0.4 years followup. Functioning was assessed with the modified Short-Form 12 (SF-12) questionnaire. Associations of WML progression with changes in functioning were adjusted for age, sex, and vascular risk factors. Results. Physical functioning (baseline: 44, 10th–90th percentile 29–55) improved, whereas mental functioning (baseline: 51, 10th–90th percentile 32–60) declined during followup. WML progression (highest quartile versus rest) contributed to a stronger decline in mental functioning (B = −1.76, 95% CI −3.11 to −0.42), but did not influence changes in physical functioning. Conclusions. Progression of WML volume contributes to a decline in mental functioning in patients with symptomatic atherosclerotic disease

    Некоторые проблемы добычи полезных ископаемых на глубоких горизонтах недр

    Get PDF
    Cardiovascular screening may benefit middle-aged sportsmen, as coronary artery disease (CAD) is the main cause of exercise-related sudden cardiac death. Arterial stiffness, as measured by pulse wave velocity (PWV), may help identify sportsmen with subclinical CAD. We examined the additional value of PWV measurements to traditional CAD risk factors for identifying CAD.From the Measuring Athlete's Risk of Cardiovascular events (MARC) cohort of asymptomatic, middle-aged sportsmen who underwent low-dose Cardiac CT (CCT) after routine sports medical examination (SME), 193 consecutive sportsmen (aged 55 ± 6.6 years) were included with additional PWV measurements before CCT. Sensitivity, specificity and predictive values of PWV values (>8.3 and >7.5 m/s) assessed by Arteriograph were used to identify CAD (coronary artery calcium scoring ≥ 100 Agatston Units or coronary CT angiography luminal stenosis ≥ 50%) and to assess the additional diagnostic value of PWV to established cardiovascular risk factors.Forty-seven sportsmen (24%) had CAD on CCT. They were older (58.9 vs. 53.8 years, p<0.001), had more hypertension (17 vs. 4%, p=0.003), higher cholesterol levels (5.7 vs. 5.4 mmol/l) p=0.048), and more often were (ever) smokers (55 vs. 34%, p=0.008). Mean PWV was higher in those with CAD (8.9 vs. 8.0 m/s, p=0.017). For PWV >8.3m/s respectively >7.5 m/s sensitivity to detect CAD on CT was 43% and 74%, specificity 69% and 45%, positive predictive value 31% and 30%, and negative predictive value 79% and 84%. Adding PWV to traditional risk factor models did not change the area under the curve (from 0.78 (95% CI = 0.709-0.848)) to AUC 0.78 (95% CI 0.710-0.848, p = 0.99)) for prediction of CAD on CCT.Limited additional value was found for PWV on top of established risk factors to identify CAD. PWV might still have a role to identify CAD in middle-aged sportsmen if risk factors such as cholesterol are unknown

    Minimally invasive image-guided therapy for inoperable hepatocellular carcinoma: What is the evidence today?

    Get PDF
    Hepatocellular carcinoma (HCC) is a primary malignant tumor of the liver that accounts for an important health problem worldwide. Only 10–15% of HCC patients are suitable candidates for hepatic resection and liver transplantation due to the advanced stage of the disease at time of diagnosis and shortage of donors. Therefore, several minimally invasive image-guided therapies for locoregional treatment have been developed. Tumor ablative techniques are either based on thermal tumor destruction, as in radiofrequency ablation, cryoablation, microwave ablation, laser ablation and high-intensity focused ultrasound, or chemical tumor destruction, as in percutaneous ethanol injection. Image-guided catheter-based techniques rely on intra-arterial delivery of embolic, chemoembolic or radioembolic agents. These minimally invasive image-guided therapies have revolutionized the management of inoperable HCC. This review provides a description of all minimally invasive image-guided therapies currently available, an up-to-date overview of the scientific evidence for their clinical use, and thoughts for future directions

    Computer-aided detection (CAD) for breast MRI: evaluation of efficacy at 3.0 T

    Get PDF
    OBJECTIVE: The purpose of the study was to evaluate the accuracy of 3.0-T breast MRI interpretation using manual and fully automated kinetic analyses. MATERIAL AND METHODS: Manual MRI interpretation was done on an Advantage Workstation. Retrospectively, all examinations were processed with a computer-aided detection (CAD) system. CAD data sets were interpreted by two experienced breast radiologists and two residents. For each lesion automated analysis of enhancement kinetics was evaluated at 50% and 100% thresholds. Forty-nine malignant and 22 benign lesions were evaluated. RESULTS: Using threshold enhancement alone, the sensitivity and specificity of CAD were 97.9% and 86.4%, respectively, for the 50% threshold, and 97.9% and 90%, respectively, for the 100% threshold. Manual interpretation by two breast radiologists showed a sensitivity of 84.6% and a specificity of 68.8%. For the same two radiologists the mean sensitivity and specificity for CAD-based interpretation was 90.4% (not significant) and 81.3% (significant at p < 0.05), respectively. With one-way ANOVA no significant differences were found between the two breast radiologists and the two residents together, or between any two readers separately. CONCLUSION: CAD-based analysis improved the specificity compared with manual analysis of enhancement. Automated analysis at 50% and 100% thresholds showed a high sensitivity and specificity for readers with varying levels of experience

    Prediction of Cardiovascular Events by Using Non-Vascular Findings on Routine Chest CT

    Get PDF
    Background: Routine computed tomography (CT) examinations contain an abundance of findings unrelated to the diagnostic question. Those with prognostic significance may contribute to early detection and treatment of disease, irrelevant findings can be ignored. We aimed to assess the association between unrequested chest CT findings in lungs, mediastinum and pleura and future cardiovascular events. Methods: Multi-center case-cohort study in 5 tertiary and 3 secondary care hospitals involving 10410 subjects who underwent routine chest CT for non-cardiovascular reasons. 493 cardiovascular hospitalizations or deaths were recorded during an average follow-up time of 17.8 months. 1191 patients were randomly sampled to serve as a control subcohort. Hazard ratios and annualized event rates were calculated. Results: Abnormalities in the lung (26–44%), pleura (14–15%) and mediastinum (20%) were common. Hazard ratios after adjustment for age and sex were for airway wall thickening 2.26 (1.59–3.22), ground glass opacities 2.50 (1.72–3.62), consolidations 1.97 (1.12–3.47), pleural effusions 2.77 (1.81–4.25) and lymph-nodes 2.04 (1.40–2.96). Corresponding annual event rates were 5.5%, 6.0%, 3.8%, 10.2 % and 4.4%. Conclusions: We have identified several common chest CT findings that are predictive for future risk of cardiovascular events and found that other findings have little utility for this. The added value of the non-vascular predictors to establishe

    Использование растровых графических редакторов для обработки археологических материалов

    Get PDF
    В данной работе предлагается к рассмотрению компьютерная графика в качестве инструмента для создания стратиграфических чертежей и приводится краткое описание технологии, которая сегодня широко используется при составлении отчетов многих археологических экспедиций в Крыму

    Baseline MDCT findings after prosthetic heart valve implantation provide important complementary information to echocardiography for follow-up purposes

    Get PDF
    Objectives: Recent studies have proposed additional multidetector-row CT (MDCT) for prosthetic heart valve (PHV) dysfunction. References to discriminate physiological from pathological conditions early after implantation are lacking. We present baseline MDCT findings of PHVs 6 weeks post implantation. Methods: Patients were prospectively enrolled and TTE was performed according to clinical guidelines. 256-MDCT images were systematically assessed for leaflet excursions, image quality, valve-related artefacts, and pathological and additional findings. Results: Forty-six patients were included comprising 33 mechanical and 16 biological PHVs. Overall, MDCT image quality was good and relevant regions remained reliably assessable despite mild-moderate PHV-artefacts. MDCT detected three unexpected valve-related pathology cases: (1) prominent subprosthetic tissue, (2) pseudoaneurysm and (3) extensive pseudoaneurysms and valve dehiscence. The latter patient required valve surgery to be redone. TTE only showed trace periprosthetic regurgitation, and no abnormalities in the other cases. Additional findings were: tilted aortic PHV position (n = 3), pericardial haematoma (n = 3) and pericardial effusion (n = 3). Periaortic induration was present in 33/40 (83 %) aortic valve patients. Conclusions: MDCT allowed evaluation of relevant PHV regions in all valves, revealed baseline postsurgical findings and, despite normal TTE findings, detected three cases of unexpected, clinically relevant pathology. Key Points: • Postoperative MDCT presents baseline morphology relevant for prosthetic valve follow-up. • 83 % of patients show periaortic induration 6 weeks after aortic valve replacement. • MDCT detected three cases of clinically relevant pathology not found with TTE. • Valve dehiscence detection by MDCT required redo valve surgery in one patient. • MDCT is a suitable and complementary imaging tool for follow-up purposes

    Prosthetic heart valve assessment with multidetector-row CT: imaging characteristics of 91 valves in 83 patients

    Get PDF
    Multidetector CT (MDCT) has shown potential for prosthetic heart valve (PHV) assessment. We assessed the image quality of different PHV types to determine which valves are suitable for MDCT evaluation. All ECG-gated CTs performed in our institutions since 2003 were reviewed for the presence of PHVs. After reconstruction in 3 specific PHV planes, image quality of the supravalvular, perivalvular, subvalvular and valvular regions was scored on a four-point scale (1 = non-diagnostic, 2 = moderate, 3 = good and 4 = excellent) by two independent observers. Eighty-four CT examinations (66 cardiac, 18 limited-dose aortic protocols) of 83 patients with a total of 91 PHVs in the aortic (n = 71), mitral (n = 17), pulmonary (n = 1) and tricuspid (n = 2) position were included. CT was performed on a 16-slice (n = 4), 64-slice (n = 28) or 256-slice (n = 52) MDCT system. Median image quality scores for the supra-, peri- and subvalvular regions and valvular detail were (3.5, 3.3, 3.5 and 3.5, respectively) for bileaflet PHV; (3.0, 3.0, 3.5 and 3.0, respectively) for Medtronic Hall PHV; (1.0, 1.0, 1.0 and 1.0, respectively) for Björk-Shiley and Sorin monoleaflet PHV and (3.5, 3.5, 4.0 and 2.0 respectively) for biological PHV. Currently implanted PHVs have good image quality on MDCT and are suitable for MDCT evaluatio
    corecore