99 research outputs found

    Protocol for German trial of Acyclovir and corticosteroids in Herpes-simplex-virus-encephalitis (GACHE): a multicenter, multinational, randomized, double-blind, placebo-controlled German, Austrian and Dutch trial [ISRCTN45122933]

    Get PDF
    Background The treatment of Herpes-simplex-virus-encephalitis (HSVE) remains a major unsolved problem in Neurology. Current gold standard for therapy is acyclovir, a drug that inhibits viral replication. Despite antiviral treatment, mortality remains up to 15%, less than 20% of patients are able to go back to work, and the majority of patients suffer from severe disability. This is a discouraging, unsatisfactory situation for treating physicians, the disabled patients and their families, and constitutes an enormous burden to the public health services. The information obtained from experimental animal research and from recent retrospective clinical observations, indicates that a substantial benefit in outcome can be expected in patients with HSVE who are treated with adjuvant dexamethasone. But currently there is no available evidence to support the routine use of adjuvant corticosteroid treatment in HSVE. A randomized multicenter trial is the only useful instrument to address this question. Design GACHE is a multicenter, randomized, double-blind, placebo-controlled, parallel group clinical trial of treatment with acyclovir and adjuvant dexamethasone, as compared with acyclovir and placebo in adults with HSVE. The statistical design will be that of a 3-stage-group sequential trial with potential sample size adaptation in the last stage. Conclusion 372 patients with proven HSVE (positive HSV-DNA-PCR), aged 18 up to 85 years; with focal neurological signs no longer than 5 days prior to admission, and who give informed consent will be recruited from Departments of Neurology of academic medical centers in Germany, Austria and The Netherlands. Sample size will potentially be extended after the second interim analysis up to a maximum of 450 patients. Trial Registration Current Controlled Trials ISRCTN4512293

    An alternative to the hand searching gold standard: validating methodological search filters using relative recall

    Get PDF
    BACKGROUND: Search filters or hedges play an important role in evidence-based medicine but their development depends on the availability of a "gold standard" – a reference standard against which to establish the performance of the filter. We demonstrate the feasibility of using relative recall of included studies from multiple systematic reviews to validate methodological search filters as an alternative to validation against a gold standard formed through hand searching. METHODS: We identified 105 Cochrane reviews that used the Highly Sensitive Search Strategy (HSSS), included randomized or quasi-randomized controlled trials, and reported their included studies. We measured the ability of two published and one novel variant of the HSSS to retrieve the MEDLINE-index studies included in these reviews. RESULTS: The systematic reviews were comprehensive in their searches. 72% of included primary studies were indexed in MEDLINE. Relative recall of the three strategies ranged from .98 to .91 across all reviews and more comprehensive strategies showed higher recall. CONCLUSION: An approach using relative recall instead of a hand searching gold standard proved feasible and produced recall figures that were congruent with previously published figures for the HSSS. This technique would permit validation of a methodological filter using a collection of approximately 100 studies of the chosen design drawn from the included studies of multiple systematic reviews that used comprehensive search strategies

    A New Method to Predict the Epidemiology of Fungal Keratitis by Monitoring the Sales Distribution of Antifungal Eye Drops in Brazil

    Get PDF
    Purpose: Fungi are a major cause of keratitis, although few medications are licensed for their treatment. The aim of this study is to observe the variation in commercialisation of antifungal eye drops, and to predict the seasonal distribution of fungal keratitis in Brazil. Methods: Data from a retrospective study of antifungal eye drops sales from the only pharmaceutical ophthalmologic laboratory, authorized to dispense them in Brazil (Opthalmos) were gathered. These data were correlated with geographic and seasonal distribution of fungal keratitis in Brazil between July 2002 and June 2008. Results: A total of 26,087 antifungal eye drop units were sold, with a mean of 2.3 per patient. There was significant variation in antifungal sales during the year (p < 0.01). A linear regression model displayed a significant association between reduced relative humidity and antifungal drug sales (R-2 = 0.17, p < 0.01). Conclusions: Antifungal eye drops sales suggest that there is a seasonal distribution of fungal keratitis. A possible interpretation is that the third quarter of the year (a period when the climate is drier), when agricultural activity is more intense in Brazil, suggests a correlation with a higher incidence of fungal keratitis. A similar model could be applied to other diseases, that are managed with unique, or few, and monitorable medications to predict epidemiological aspects.Conselho Nacional de Desenvolvimento Cientifico e TecnologicoConselho Nacional de Desenvolvimento Cientifico e Tecnologico [302005/2009-9]Fundacao de Apoio ao Ensino, Pesquisa e Assistencia do Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto da Universidade de Sao PauloFundacao de Apoio ao Ensino, Pesquisa e Assistencia do Hospital das Clinicas da Faculdade de Medicina de Ribeirao Preto da Universidade de Sao Paul

    Heat Shock Proteins and Amateur Chaperones in Amyloid-Beta Accumulation and Clearance in Alzheimer’s Disease

    Get PDF
    The pathologic lesions of Alzheimer’s disease (AD) are characterized by accumulation of protein aggregates consisting of intracellular or extracellular misfolded proteins. The amyloid-β (Aβ) protein accumulates extracellularly in senile plaques and cerebral amyloid angiopathy, whereas the hyperphosphorylated tau protein accumulates intracellularly as neurofibrillary tangles. “Professional chaperones”, such as the heat shock protein family, have a function in the prevention of protein misfolding and subsequent aggregation. “Amateur” chaperones, such as apolipoproteins and heparan sulfate proteoglycans, bind amyloidogenic proteins and may affect their aggregation process. Professional and amateur chaperones not only colocalize with the pathological lesions of AD, but may also be involved in conformational changes of Aβ, and in the clearance of Aβ from the brain via phagocytosis or active transport across the blood–brain barrier. Thus, both professional and amateur chaperones may be involved in the aggregation, accumulation, persistence, and clearance of Aβ and tau and in other Aβ-associated reactions such as inflammation associated with AD lesions, and may, therefore, serve as potential targets for therapeutic intervention

    Simplified automatic method for measuring the visual field using the perimeter ZERK 1

    Get PDF
    Background: Currently available perimeters have limited capabilities of performing measurements of the visual field in children. In addition, they do not allow for fully automatic measurement even in adults. The patient in each case (in any type of perimeter) has at his disposal a button which he uses to indicate that he has seen a light stimulus. Such restrictions have been offset in the presented new perimeter ZERK 1. Methods: The paper describes a new type of automated, computerized perimeter designed to test the visual field in children and adults. The new perimeter and proprietary software enable to carry out tests automatically (without the need to press any button). The presented full version of the perimeter has been tested on a head phantom. The next steps will involve clinical trials and a comparison with measurements obtained using other types of perimeters. Results: The perimeter ZERK 1 enables automatic measurement of the visual field in two axes (with a span of 870 mm and a depth of 525 mm) with an accuracy of not less than 1o (95 LEDs on each arm) at a typical position of the patient's head. The measurement can be carried out in two modes: default/typical (lasting about 1 min), and accurate (lasting about 10 min). Compared with available and known types of perimeters, it has an open canopy, proprietary software and cameras tracking the eye movement, automatic control of fixation points, light stimuli with automatically preset light stimulus intensity in the following ranges: 550-700 mcd (red 620-630 nm), 1100-1400 mcd (green 515-530 nm), 200-400 mcd (blue 465-475 nm). Conclusions: The paper presents a new approach to the construction of perimeters based on automatic tracking of the eye movements in response to stimuli. The unique construction of the perimeter and the software allow for its mobile use in the examination of children and bedridden patients
    corecore