7 research outputs found

    Editor's Choice - The Impact of Centralisation and Endovascular Aneurysm Repair on Treatment of Ruptured Abdominal Aortic Aneurysms Based on International Registries

    Get PDF
    Objectives: Current management of ruptured abdominal aortic aneurysms (RAAA) varies among centres and countries, particularly in the degree of implementation of endovascular aneurysm repair (EVAR) and levels of vascular surgery centralisation. This study assesses these variations and the impact they have on outcomes. Materials and methods: RAAA repairs from vascular surgical registries in 11 countries, 2010-2013, were investigated. Data were analysed overall, per country, per treatment modality (EVAR or open aortic repair [OAR]), centre volume (quintiles IV), and whether centres were predominantly EVAR (>= 50% of RAAA performed with EVAR [EVAR(p)]) or predominantly OAR [OAR(p)]. Primary outcome was peri-operative mortality. Data are presented as either mean values or percentages with 95% CI within parentheses, and compared with chi-square tests, as well as with adjusted OR. Results: There were 9273 patients included. Mean age was 74.7 (74.5-74.9) years, and 82.7% of patients were men (81.9-83.6). Mean AAA diameter at rupture was 7.6 cm (7.5-7.6). Of these aneurysms, 10.7% (10.0-11.4) were less than 5.5 cm. EVAR was performed in 23.1% (22.3-24.0). There were 6817 procedures performed in OAR(p) centres and 1217 performed in EVAR(p) centres. Overall peri-operative mortality was 28.8% (27.9-29.8). Peri-operative mortality for OAR was 32.1% (31.0-33.2) and for EVAR 17.9% (16.3-19.6), p 22 repairs per year), 23.3% (21.2-25.4) than in QII-V, 30.0% (28.9-31.1), p <.001. Peri-operative mortality after OAR was lower in high volume centres compared with the other centres, 25.3% (23.0-27.6) and 34.0% (32.7-35.4), respectively, p <.001. There was no significant difference in peri-operative mortality after EVAR between centres based on volume. Conclusions: Peri-operative mortality is lower in centres with a primary EVAR approach or with high case volume. Most repairs, however, are still performed in low volume centres and in centres with a primary OAR strategy. Reorganisation of acute vascular surgical services may improve outcomes of RAAA repair. (C) 2018 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.Peer reviewe

    Variations in Abdominal Aortic Aneurysm Care A Report From the International Consortium of Vascular Registries

    Get PDF
    BACKGROUND: This project by the ICVR (International Consortium of Vascular Registries), a collaboration of 11 vascular surgical quality registries, was designed to evaluate international variation in the contemporary management of abdominal aortic aneurysm (AAA) with relation to recommended treatment guidelines from the Society for Vascular Surgery and the European Society for Vascular Surgery. METHODS: Registry data for open and endovascular AAA repair (EVAR) during 2010 to 2013 were collected from 11 countries. Variations in patient selection and treatment were compared across countries and across centers within countries. RESULTS: Among 51 153 patients, 86% were treated for intact AAA (iAAA) and 14% for ruptured AAA. Women constituted 18% of the entire cohort (range, 12% in Switzerland-21% in the United States; P CONCLUSIONS: Despite homogeneous guidelines from professional societies, significant variation exists in the management of AAA, most notably for iAAA diameter at repair, use of EVAR, and the treatment of elderly patients. ICVR provides an opportunity to study treatment variation across countries and to encourage optimal practice by sharing these results.Peer reviewe

    International Consortium of Vascular Registries Consensus Recommendations for Peripheral Revascularisation Registry Data Collection

    Get PDF
    Objective/Background: To achieve consensus on the minimum core data set for evaluation of peripheral arterial revascularisation outcomes and enable collaboration among international registries. Methods: A modified Delphi approach was used to achieve consensus among international vascular surgeons and registry members of the International Consortium of Vascular Registries (ICVR). Variables, including definitions, from registries covering open and endovascular surgery, representing 14 countries in ICVR, were collected and analysed to define a minimum core data set and to develop an optimum data set for registries. Up to three different levels of variable specification were suggested to allow inclusion of registries with simpler versus more complex data capture, while still allowing for data aggregation based on harmonised core definitions. Results: Among 31 invited experts, 25 completed five Delphi rounds via internet exchange and face to face discussions. In total, 187 different items from the various registry data forms were identified for potential inclusion in the recommended data set. Ultimately, 79 items were recommended for inclusion in minimum core data sets, including 65 items in the level 1 data set, and an additional 14 items in the more specific level 2 and 3 recommended data sets. Data elements were broadly divided into (i) patient characteristics; (ii) comorbidities; (iii) current medications; (iv) lesion treated; (v) procedure; (vi) bypass; (vii) endarterectomy (viii) catheter based intervention; (ix) complications; and (x) follow up. Conclusion: A modified Delphi study allowed 25 international vascular registry experts to achieve a consensus recommendation for a minimum core data set and an optimum data set for peripheral arterial revascularisation registries. Continued global harmonisation of registry infrastructure and definition of items will overcome limitations related to single country investigations and enhance the development of real world evidence. (C) 2018 European Society for Vascular Surgery. Published by Elsevier B.V. All rights reserved.Peer reviewe

    Outcome of Nellix-EVAS: single center mid-term results

    No full text
    Abstract Background Endovascular aortic sealing (EVAS) using the Nellix system was a new approach to reduce the frequency of type II endoleaks after endovascular aortic repair. We analyzed the mid-term results, specifically looking at device migration, endoleaks and subsequent necessary secondary interventions. Results Ten patients underwent elective EVAS treatment during our study period. 7 patients were within the IFU while 3 patients had a proximal neck shorter than 10 mm. Technical success rate was 100% and there were no short-term vascular complications. One patient died from urosepsis 14 days after the procedure and was excluded from further analysis. A total of 6 out of 9 patients (67%) experienced device complications such as proximal graft kinking, limb separation or caudal migration. 5 also showed type Ia endoleak. Discussion While no complication occurred short-term (up to 12 months), the Nellix system showed a high percentage of limb separation, caudal graft migration, and type Ia endoleak on mid-term follow-up, likely due to insufficient proximal anchoring of the device. Possible salvage treatments are discussed
    corecore