1,141 research outputs found
Investigation of single-crystal ferrite thin film
Chemical vapor deposition growth of epitaxial single crystal lithium ferrite thin film
Static stability and control characteristics of two large-dihedral right triangular pyramid lifting reentry configurations at a Mach number of 3.05
Static stability and control characteristics of dihedral right triangular pyramid lifting reentry vehicle configuration
Investigation of single crystal ferrite thin film Semiannual report, 1 Feb. - 31 Jul. 1969
Vapor deposition of single crystal thin films of lithium ferrite utilizing ferric chlorid
Chemical Lawn Mowers - How Close to Perfection?
Don\u27t discard your mower yet - but a chemical spray may reduce the amount of future mowing required by a considerable amount. Chemical lawn mowing also holds promise for roadside areas and inaccessible spots
Investigation of single crystal ferrite thin films
Materials suitable for use in magnetic bubble domain memories were developed for aerospace applications. Practical techniques for the preparation of such materials in forms required for fabrication of computer memory devices were considered. The materials studied were epitaxial films of various compositions of the gallium-substituted yttrium gadolinium iron garnet system. The major emphasis was to determine their bubble properties and the conditions necessary for growing uncracked, high quality films
An all-optical trap for a gram-scale mirror
We report on a stable optical trap suitable for a macroscopic mirror, wherein
the dynamics of the mirror are fully dominated by radiation pressure. The
technique employs two frequency-offset laser fields to simultaneously create a
stiff optical restoring force and a viscous optical damping force. We show how
these forces may be used to optically trap a free mass without introducing
thermal noise; and we demonstrate the technique experimentally with a 1 gram
mirror. The observed optical spring has an inferred Young's modulus of 1.2 TPa,
20% stiffer than diamond. The trap is intrinsically cold and reaches an
effective temperature of 0.8 K, limited by technical noise in our apparatus.Comment: Major revision. Replacement is version that appears in Phy. Rev.
Lett. 98, 150802 (2007
Squeezing in the audio gravitational wave detection band
We demonstrate the generation of broad-band continuous-wave optical squeezing
down to 200Hz using a below threshold optical parametric oscillator (OPO). The
squeezed state phase was controlled using a noise locking technique. We show
that low frequency noise sources, such as seed noise, pump noise and detuning
fluctuations, present in optical parametric amplifiers have negligible effect
on squeezing produced by a below threshold OPO. This low frequency squeezing is
ideal for improving the sensitivity of audio frequency measuring devices such
as gravitational wave detectors.Comment: 5 pages, 6 figure
System for MR image-guided prostate interventions: canine study
Cataloged from PDF version of article.The purpose of this study was to demonstrate the use of a transrectal system that enables precise magnetic resonance (MR) image guidance and monitoring of prostate interventions. The system used a closed-bore 1.5-T MR imaging unit and enables one to take advantage of the higher signal-to-noise ratio achieved with traditional magnet designs, which is crucial for accurate targeting and monitoring of prostate interventions. In the first of the four canine studies, reliable needle placement, with all needles placed within 2 mm of the desired target site, was achieved. In two other studies, MR imaging was used to monitor distribution of injected contrast agent solution (gadopentetate dimeglumine mixed with trypan blue dye) in and around the prostate, thereby confirming that solution had been delivered to the desired tissue and also detecting faulty injections. In the final study, accurate placement and MR imaging of brachytherapy seeds in the prostate were demonstrated. The described system provides a flexible platform for a variety of minimally invasive MR image-guided therapeutic and diagnostic prostate interventions
Transrectal Prostate Biopsy and Fiducial Marker Placement in a Standart 1.5T Magnetic Resonance Imaging Scanner
Cataloged from PDF version of article.Purpose: We investigated the accuracy and feasibility of a system that provides transrectal needle access to the prostate concurrent with 1.5 Tesla MRI which previously has not been possible.
Materials and Methods: In 5 patients with previously diagnosed prostate cancer, MRI guided intraprostatic placement of gold fiducial markers (4 procedures) and/or prostate biopsy (3 procedures) was performed using local anesthesia.
Results: Mean procedure duration was 76 minutes and all patients tolerated the intervention well. Procedure related adverse events included self-limited hematuria and hematochezia following 3 of 8 procedures (all resolved in less than 1 week). Mean needle placement accuracy was 1.9 mm for the fiducial marker placement studies and 1.8 mm for the biopsy procedures. Mean fiducial marker placement accuracy was 4.8 mm and the mean fiducial marker placement accuracy transverse to the needle direction was 2.6 mm. All patients who underwent the procedure were able to complete their course of radiotherapy without delay or complication.
Conclusions: While studies of clinical usefulness are warranted, transrectal 1.5 T MRI guided prostate biopsy and fiducial marker placement is feasible using this system, providing new opportunities for image guided diagnostic and therapeutic prostate interventions
- …