9,273 research outputs found

    Response of mouse epidermal cells to single doses of heavy-particles

    Get PDF
    The survival of mouse epidermal cells to heavy-particles has been studied In Vivo by the Withers clone technique. Experiments with accelerated helium, lithium and carbon ions were performed. The survival curve for the helium ion irradiations used a modified Bragg curve method with a maximum tissue penetration of 465 microns, and indicated that the dose needed to reduce the original cell number to 1 surviving cell/square centimeters was 1525 rads with a D sub o of 95 rads. The LET at the basal cell layer was 28.6 keV per micron. Preliminary experiments with lithium and carbon used treatment doses of 1250 rads with LET's at the surface of the skin of 56 and 193 keV per micron respectively. Penetration depths in skin were 350 and 530 microns for the carbon and lithium ions whose Bragg curves were unmodified. Results indicate a maximum RBE for skin of about 2 using the skin cloning technique. An attempt has been made to relate the epidermal cell survival curve to mortality of the whole animal for helium ions

    Light scattering study of the “pseudo-layer” compression elastic constant in a twist-bend nematic liquid crystal

    Get PDF
    The nematic twist-bend (TB) phase, exhibited by certain achiral thermotropic liquid crystalline (LC) dimers, features a nanometer-scale, heliconical rotation of the average molecular long axis (director) with equally probable left- and right-handed domains. On meso to macroscopic scales, the TB phase may be considered as a stack of equivalent slabs or “pseudo-layers”, each one helical pitch in thickness. The long wavelength fluctuation modes should then be analogous to those of a smectic-A phase, and in particular the hydrodynamic mode combining “layer” compression and bending ought to be characterized by an effective layer compression elastic constant Beff and average director splay constant Keff1. The magnitude of Keff1 is expected to be similar to the splay constant of an ordinary nematic LC, but due to the absence of a true mass density wave, Beff could differ substantially from the typical value of ∼10⁶ Pa in a conventional smectic-A. Here we report the results of a dynamic light scattering study, which confirms the “pseudo-layer” structure of the TB phase with Beff in the range 10³–10⁴ Pa. We show additionally that the temperature dependence of Beff at the TB to nematic transition is accurately described by a coarse-grained free energy density, which is based on a Landau-deGennes expansion in terms of a heli-polar order parameter that characterizes the TB state and is linearly coupled to bend distortion of the director

    Solid friction between soft filaments

    Full text link
    Any macroscopic deformation of a filamentous bundle is necessarily accompanied by local sliding and/or stretching of the constituent filaments. Yet the nature of the sliding friction between two aligned filaments interacting through multiple contacts remains largely unexplored. Here, by directly measuring the sliding forces between two bundled F-actin filaments, we show that these frictional forces are unexpectedly large, scale logarithmically with sliding velocity as in solid-like friction, and exhibit complex dependence on the filaments' overlap length. We also show that a reduction of the frictional force by orders of magnitude, associated with a transition from solid-like friction to Stokes' drag, can be induced by coating F-actin with polymeric brushes. Furthermore, we observe similar transitions in filamentous microtubules and bacterial flagella. Our findings demonstrate how altering a filament's elasticity, structure and interactions can be used to engineer interfilament friction and thus tune the properties of fibrous composite materials

    Potentiation of C1 esterase inhibitor by StcE, a metalloprotease secreted by escherichia coli O157:H7

    Get PDF
    The complement system is an essential component of host defense against pathogens. Previous research in our laboratory identified StcE, a metalloprotease secreted by Escherichia coli O157:H7 that cleaves the serpin C1 esterase inhibitor (C1-INH), a major regulator of the classical complement cascade. Analyses of StcE-treated C1-INH activity revealed that surprisingly, StcE enhanced the ability of C1-INH to inhibit the classical complement-mediated lysis of sheep erythrocytes. StcE directly interacts with both cells and C1-INH, thereby binding C1-INH to the cell surface. This suggests that the augmented activity of StcE-treated C1-INH is due to the increased concentration of C1-INH at the sites of potential lytic complex formation. Indeed, removal of StcE abolishes the ability of C1-INH to bind erythrocyte surfaces, whereas the proteolysis of C1-INH is unnecessary to potentiate its inhibitory activity. Physical analyses showed that StcE interacts with C1-INH within its aminoterminal domain, allowing the unaffected serpin domain to interact with its targets. In addition, StcE-treated C1-INH provides significantly increased serum resistance to E. coli K-12 over native C1-INH. These data suggest that by recruiting C1-INH to cell surfaces, StcE may protect both E. coli O157:H7 and the host cells to which the bacterium adheres from complement-mediated lysis and potentially damaging inflammatory events

    The redshift of the gravitationally lensed radio source PKS1830-211

    Get PDF
    We report on the spectroscopic identification and the long awaited redshift measurement of the heavily obscured, gravitationally lensed radio source PKS 1830-211, which was first observed as a radio Einstein ring. The NE component of the doubly imaged core is identified, in our infrared spectrum covering the wavelength range 1.5-2.5 microns, as an impressively reddened quasar at z=2.507. Our redshift measurement, together with the recently measured time delay (Lovell et al.), means that we are a step closer to determining the Hubble constant from this lens. Converting the time delay into the Hubble constant by using existing models leads to high values for the Hubble constant. Since the lensing galaxy lies very close to the center of the lensed ring, improving the error bars on the Hubble constant will require not only a more precise time delay measurement, but also very precise astrometry of the whole system.Comment: 11 pages, 2 figures, Accepted ApJ

    A Bayesian approach to the follow-up of candidate gravitational wave signals

    Full text link
    Ground-based gravitational wave laser interferometers (LIGO, GEO-600, Virgo and Tama-300) have now reached high sensitivity and duty cycle. We present a Bayesian evidence-based approach to the search for gravitational waves, in particular aimed at the followup of candidate events generated by the analysis pipeline. We introduce and demonstrate an efficient method to compute the evidence and odds ratio between different models, and illustrate this approach using the specific case of the gravitational wave signal generated during the inspiral phase of binary systems, modelled at the leading quadrupole Newtonian order, in synthetic noise. We show that the method is effective in detecting signals at the detection threshold and it is robust against (some types of) instrumental artefacts. The computational efficiency of this method makes it scalable to the analysis of all the triggers generated by the analysis pipelines to search for coalescing binaries in surveys with ground-based interferometers, and to a whole variety of signal waveforms, characterised by a larger number of parameters.Comment: 9 page

    Reference Standards for Body Fat Measure Using GE Dual Energy X-Ray Absorptiometry in Caucasian Adults

    Full text link
    Background Dual energy x-ray absorptiometry (DXA) is an established technique for the measurement of body composition. Reference values for these variables, particularly those related to fat mass, are necessary for interpretation and accurate classification of those at risk for obesityrelated health complications and in need of lifestyle modifications (diet, physical activity, etc.). Currently, there are no reference values available for GE-Healthcare DXA systems and it is known that whole-body and regional fat mass measures differ by DXA manufacturer. Objective To develop reference values by age and sex for DXA-derived fat mass measurements with GE-Healthcare systems. Methods A de-identified sample of 3,327 participants (2,076 women, 1,251 men) was obtained from Ball State University\u27s Clinical Exercise Physiology Laboratory and University of Wisconsin- Milwaukee\u27s Physical Activity & Health Research Laboratory. All scans were completed using a GE Lunar Prodigy or iDXA and data reported included percent body fat (%BF), fat mass index (FMI), and ratios of android-to-gynoid (A/G), trunk/limb, and trunk/leg fat measurements. Percentiles were calculated and a factorial ANOVA was used to determine differences in the mean values for each variable between age and sex. Results Normative reference values for fat mass variables from DXA measurements obtained from GE-Healthcare DXA systems are presented as percentiles for both women and men in 10- year age groups. Women had higher (p\u3c0.01) mean %BF and FMI than men, whereas men had higher (p\u3c0.01) mean ratios of A/G, trunk/limb, and trunk/leg fat measurements than women

    Bioresorbable Film for the Prevention of Adhesion to the Anterior Spine After Anterolateral Discectomy

    Get PDF
    Background context The development of scar tissue and adhesions postoperatively is a natural consequence of healing but can be associated with medical complications and render reoperation difficult. Many biocompatible products have been evaluated as barriers or deterrents to adhesions. Purpose To evaluate the efficacy of a bioresorbable polylactide film as a barrier to adhesion formation after anterolateral discectomy. Study design Experimental study. Methods Seven, skeletally mature female sheep underwent a retroperitoneal approach to the anterolateral lumbar spine. A discectomy was performed at two levels with an intervening unoperated disc site. One site was treated with a polylactide film barrier (Hydrosorb Shield; MacroPore Biosurgery, San Diego, CA) affixed with tacks manufactured from the same material. The second site was left untreated. Treatment and control sites were randomly assigned. Postmortem analysis included scar tenacity scoring on five spines and histological evaluation on two spines. Results The application of the Hydrosorb film barrier allowed a definite dissection plane during scar tenacity scoring and there was a significant difference in the development of adhesions to the disc between the control and treated sites. Histological evaluation revealed evidence of barrier formation to scar tissue and no significant adverse inflammatory reactions. Conclusions Hydrosorb Shield appears to be an effective postoperative barrier to scar tissue adhesion after anterolateral discectomy. The use of polylactide tacks was beneficial to affix the barrier film in place. Safety issues associated with delayed healing or adverse response to the film or tacks were not observed. Hydrosorb film may be useful as an antiadhesion barrier facilitating dissection during surgical revision in anterior approaches to the spine. Further studies are indicated to evaluate the performance of the bioresorbable material as an antiadhesion barrier in techniques of spinal fusion and disc replacement

    Bit Error Rate and Frame Error Rate Data Processing for Space Communications and Navigation-Related Communication System Analysis Tools

    Get PDF
    One of the capabilities that the Space Communications and Navigation (SCaN) Strategic Center for Networking, Integration, and Communications (SCENIC) user interface (UI) web application intends to provide its users is the addition of network protocol and link encryption augmentations of communication system analyses. Before any of these analyses capabilities can be modeled, the simulations of bit error rate (BER) and frame error rate (FER) against signal-to-noise ratio (SNR) have been conducted, requiring parameters from several known coding types (low-density parity-check (LDPC), convolutional, etc.), signal modulations (binary phase shift keying (BPSK), quadrature phase shift keying (QPSK), etc.), coding rates (1/2, 1/3, etc.), and frame sizes (1,280, 3,580, etc.). However, in order to extract useful information from the results of these simulations, a curve fitting technique has been applied to each resulting dataset to extend and extrapolate the curve fit of BER and FER down to 1030 using MATLAB Curve Fitting Toolbox (The MathWorks, Inc.). This is a necessary step because simulations of BER and FER were only performed to around 109 due to the extensive simulation time that would be required to obtain significant simulation results at the error levels desired. Furthermore, the fitted curve results were applied to a finer resolution for the SNR at 0.01-dB interval instead of the 0.05-dB interval limitation used in the simulation. All the possible combinations of the coding types, signal modulations, coding rates, frame sizes, and the extension of BER and FER curves would enable users to capture a wide range of link performances that directly relates to the addition of higher level networking data encapsulated in a frame. The curve fitting results also led to the modeling of the optical link error rate performance by solving for coding gain, FER_BER SNR delta, coded optical BER-SNR, and coded optical FERSNR
    corecore