2,065 research outputs found
Structural and magnetic properties of an InGaAs/FeSi superlattice in cylindrical geometry
The structure and the magnetic properties of an InGaAs/Fe3Si superlattice in
a cylindrical geometry are investigated by electron microscopy techniques,
x-ray diffraction and magnetometry. To form a radial superlattice, a
pseudomorphic InGaAs/Fe3As bilayer has been released from its substrate
self-forming into a rolled-up microtube. Oxide-free interfaces as well as areas
of crystalline bonding are observed and an overall lattice mismatch between
succeeding layers is determined. The cylindrical symmetry of the final radial
superlattice shows a significant effect on the magnetization behavior of the
rolled-up layers
Outpacing movement — ultrafast volume coverage in neuropediatric magnetic resonance imaging
Background Conventional MRI sequences are often affected in neuropediatric imaging by unavoidable movements. Therefore, children younger than 6 years usually have to be examined under sedation/anesthesia. A new real-time MRI technique with automatic slice advancement allows for motion-robust T2-weighted volume coverage of the whole brain within a few seconds in adults. Objective To evaluate to which extent the new volume coverage method can be used to visualize cerebrospinal fluid and reduce the need for anesthesia in children. Materials and methods We assessed 30 children ages 6 years and younger with suspected or proven hydrocephalus, hygroma or macrocephalus using volume coverage sequences with 20 slices per second in three planes. If necessary, a parent was placed in the bore together with the child for calming and gentle immobilization. We compared visualization of cerebrospinal fluid spaces and course of the shunt catheter in volume coverage sequences vs. fast spin-echo sequences. Results The clinical issue could be sufficiently assessed in all children with use of volume coverage sequences, whereas conventional fast spin-echo sequences performed moderately to poorly. Visualization of the tip of a shunt failed in 16% of volume coverage scans and 27% of turbo spin-echo scans. A subsequent examination under anesthesia was never necessary. None of the examinations had to be stopped prematurely. Conclusion The motion-robust volume coverage sequences with T2-type contrast can be used to avoid sedation of children in the evaluation of cerebrospinal fluid spaces, even in the presence of vigorous motion. For other indications and contrasts, the technique must still be evaluated
NB SPUTTER COATING ON QWR IN ANU
ABSTRACT Nb sputtered QWRs are to be used for the future extension of the Linac. The magnetron sputtering system and its operational performance are described. A magnetron discharge in argon is used for sputtering niobium and in helium for cleaning of the resonator. The cathode comprises two cylindrical and one ring element. The I-V characteristics of the sputtering in argon are given. The superconducting film is deposited with a uniform film thickness and coverage of the resonator. The distribution of the deposition rate f r o m different cathode-resonator geometry and film thickness profiles are discussed. The switching of the cylindrical sputtering cathode from external to internal regions of the cathode, is described. A sputtering procedure, t e s t depositions on ceramic samples and sputtering on the QWR for Time-Energy Lens, will be outlined. The composition of impurities stemming from t h e sputtering process, will be discussed. . I n t r o d u c t i o n The ANU accelerator system, comprising the 14UD and Linac, continues t o evolve toward a competent integrated research facility. The Linac successfully passed important milestones in 1996, including the f i r s t nuclear physics experiment performed on 5 June, and its o f f i c i a l inauguration on 11 July. Good progress has been made in the conditioning of the Pb plated, split loop resonators. Combinations of pulsed RF power conditioning and helium conditioning have enabled all resonators to operate near and above 2 MV/m
Three-centre cluster structure in 11C and 11B
Studies of the 16O(9Be,alpha 7Be)14C, 7Li(9Be,alpha 7Li)5He and 7Li(9Be,alpha
alpha t)5He reactions at E(beam)=70 and 55 MeV have been performed using
resonant particle spectroscopy techniques. The 11C excited states decaying into
alpha+7Be(gs) are observed between 8.5 and 13.5 MeV. The alpha+7Li(gs),
alpha+7Li*(4.652 MeV) and t+8Be(gs) decays of 11B excited states between 9 and
19 MeV are observed. The decay processes are used to indicate the possible
three-centre 2alpha+3He (2alpha+3H) cluster structure of observed states. This
cluster structure is more prominent in the positive-parity states, where two
rotational bands with large deformations are suggested. Excitations of some of
the observed T=1/2 resonances coincide with the energies of previously measured
T=3/2 isobaric analogs of the 11Be states,indicating that these states may have
mixed isospin.Comment: Contribution for the proceedings of the NUSTAR'05: NUclear STructure,
Astrophysics and Reactions, University of Surrey, Guildford, UK; accepted for
publication in Journal of Physics
Composition analysis of liquid particles in the Arctic stratosphere under synoptic conditions
International audienceSynoptic scale polar stratospheric clouds (PSCs) that formed without the presence of mountain lee waves were observed in early December 2002 from Kiruna/Sweden using balloon-borne instruments. The physical, chemical, and optical properties of the particles were measured. Within the PSC solid particles existed whenever the temperature was below the equilibrium temperature for nitric acid trihydrate and liquid particles appeared when the temperature fell below an even lower threshold about 3 K above the frost point with solid particles still present. The correlation of liquid supercooled ternary solution aerosols with local temperatures is a pronounced feature observed during this flight; average molar ratios H2O/HNO3 were somewhat higher than predicted by models. In addition HCl has been measured for the first time in liquid aerosols. The chlorine isotope signature served as a unique tool to identify unambiguously HCl dissolved in STS particles. Within a narrow temperature range of about three degrees above the frost point, the measured average amount of HCl in liquid particles is below 1 weight%
Composition analysis of liquid particles in the Arctic stratosphere
International audienceSynoptic scale polar stratospheric clouds (PSCs) that formed without the presence of mountain leewaves were observed in early December 2002 from Kiruna/Sweden using balloon-borne instruments. The physical, chemical, and optical properties of the particles were measured. Within the PSC solid particles existed whenever the temperature was below the equilibrium temperature for nitric acid trihydrate and liquid particles appeared when the temperature fell below an even lower threshold about 3 K above the frost point. The correlation of liquid supercooled ternary solution aerosols with local temperatures is a pronounced feature observed during this flight although the molar ratios H2O/HNO3 were about a factor of 2 higher than model predictions. In addition HCl has been measured for the first time in liquid aerosols. The chlorine isotope signature served as a unique tool to identify unambiguously HCl dissolved in STS particles. Within a narrow temperature range of about three degrees above the frost point, measured HCl molar ratios are below 1 weight%. There is only fair agreement with model predictions
Galactomannan Does Not Precede Major Signs on a Pulmonary Computerized Tomographic Scan Suggestive of Invasive Aspergillosis in Patients with Hematological Malignancies
Background. Detection of serum galactomannan (GM) antigen and presence of the halo sign on a pulmonary computerized tomographic (CT) scan have a high specificity but a low sensitivity to diagnose invasive aspergillosis (IA) in patients at risk for this disease. To our knowledge, the relationship between the time at which pulmonary infiltrates are detected by CT and the time at which GM antigens are detected by enzyme immunoassay (EIA) has not been studied. Methods. In a prospective study, tests for detection of GM were performed twice weekly for patients with hematological malignancies who had undergone hematopoetic stem cell transplantation (HSCT) or had received induction and/or consolidation chemotherapy. A pulmonary CT scan was performed once weekly. Infiltrates were defined as either major or minor signs. IA was classified as proven, probable, or possible, in accordance with the definition stated by the European Organization for Research and Treatment of Cancer-Invasive Fungal Infections Cooperative Group and the National Institute of Allergy and Infectious Diseases Mycoses Study Group. Results. We analyzed 161 episodes of infection in 107 patients (65 allogeneic HSCT recipients, 30 autologous HSCT recipients, and 66 induction and/or consolidation chemotherapy recipients). A total of 109 episodes with no IA, 32 episodes with possible IA, and 20 episodes with probable or proven IA were identified. Minor pulmonary signs were detected by CT in 70 episodes (43%), and major pulmonary signs were detected by CT in 11 episodes (7%). Univariate and multivariate analyses revealed no significant association between detection of GM by EIA and detection of abnormal pulmonary signs by CT. A significant association was found between GM levels and receipt of piperacillin-tazobactam. GM test results were not positive before major signs were seen on CT images. Only 7 (10%) of 70 patients with minor pulmonary signs had positive GM test results before detection of the greatest pathologic change by CT. Conclusions. We show that detection of GM by EIA does not precede detection of major lesions by pulmonary CT. In the clinical setting, the decision to administer mold-active treatment should based on detection of new pulmonary infiltrates on CT performed early during infection, rather than on results of EIA for detection of G
Recommended from our members
Light-triggered CO release from nanoporous non-wovens
The water insoluble and photoactive CO releasing molecule dimanganese decacarbonyl (CORM-1) has been non-covalently embedded into poly(l-lactide-co-d/ l-lactide) fibers via electrospinning to enable bioavailability and water accessibility of CORM-1. SEM images of the resulting hybrid non-wovens reveal a nanoporous fiber morphology. Slight CO release from the CORM-1 in the electrospinning process induces nanoporosity. IR spectra show the same set of carbonyl bands for the CORM-1 precursor and the non-woven. When the material was exposed to light (365-480 nm), CO release from the incorporated CORM-1 was measured via heterogeneous myoglobin assay, a portable CO electrode and an IR gas cuvette. The CO release rate was wavelength dependent. Irradiation at 365 nm resulted in four times faster release than at 480 nm. 3.4 ÎĽmol of CO per mg non-woven can be generated. Mouse fibroblast 3T3 cells were used to show that the hybrid material is non-toxic in the darkness and strongly photocytotoxic when light is applied
A Novel Eddy Current Septum Magnet for SPS Extraction towards LHC and CNGS
A new East Fast-Extraction System is under construction in the SPS, to supply particles with a maximum batch length of 7.8 us and 10.5 us to the LHC and to CNGS (CERN Neutrino to Gran Sasso), respectively. The extraction septum magnets actually used at the SPS have been designed for slow extraction over several seconds, have large cooling and electrical power demands and need frequently maintenance in a high radiation environment. A fast system of only 250 us pulse duration has therefore been developed, using a half-sine excitation pulse with a superimposed third harmonic. The short pulse duration requires very thin magnetic yoke laminations, which can not easily be stamped and stacked. Profiting from a development for the LHC beam dump kicker magnets, the yoke is therefore built-up from tape-wound cylindrical cores, employing 50 um thick Si-steel tape. Thirty two cores are stacked longitudinally to produce a yoke of 3.2 meter length. The aperture is cut radial into each cylinder. The cores are radial compressed by spring-loaded pistons inserted in strong stainless-steel frames to provide mechanical stability. The 5+1 mm thick copper/iron septum is separated from the excitation current loop and acts as a passive eddy current screen. This allows separating the vacuum of the magnet from that of the circulating-beam channel, avoiding the need of using UHV material. This paper presents the magnet and generator prototype design as well as simulation and measurement results
- …