531 research outputs found

    "Brace Technology" Thematic Series - The ScoliOlogiCÂź ChĂȘneau lightℱ brace in the treatment of scoliosis

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Bracing concepts in use today for the treatment of scoliosis include symmetric and asymmetric hard braces usually made of polyethylene (PE) and soft braces. The plaster cast method worldwide seems to be the most practiced technique for the construction of hard braces at the moment. CAD (Computer Aided Design) systems are available which allow brace adjustments without plaster. Another possibility is the use of the ScoliOlogiCℱ off the shelf system enabling the Certified Prosthetist and Orthotist (CPO) to construct a light brace for scoliosis correction from a variety of pattern specific shells to be connected to an anterior and a posterior upright. This ChĂȘneau lightℱ brace, developed according to the ChĂȘneau principles, promises a reduced impediment of quality of life in the brace. The correction effects of the first 81 patients (main diagnosis Adolescent Idiopathic Scoliosis (AIS) [n = 64] or Early Onset Scoliosis (EOS) [n = 15]), treated according to the principles of the ChĂȘneau lightℱ brace have shown a satisfactory in-brace correction exceeding 50% of the initial Cobb angle.</p> <p>Brace description</p> <p>The ScoliOlogiC<sup>Âź </sup>off the shelf bracing system enables the CPO to construct a light brace for scoliosis correction from a variety of pattern specific shells to be connected to an anterior and a posterior upright. This brace, when finally adjusted is called ChĂȘneau lightℱ brace. The advantage of this new bracing system is that the brace is available immediately, is easily adjustable and that it can also be easily modified. This avoids construction periods of sometimes more than 6 weeks, where the curve may drastically increase during periods of fast growth. The disadvantage of this bracing system is that there is a wide variability of possibilities to arrange the different shells during adjustment.</p> <p>Results</p> <p>The Cobb angle in the whole group was reduced by an average of 16,4°, which corresponds to a correction effect of 51%. The differences were highly significant in the T-test (T = 17,4; p < 0,001). The best correction effects achieved with ChĂȘneau braces reported in literature so far are about 40% in two different studies. The correction effect was highest in lumbar and thoracolumbar curve patterns (62%; n = 18). In thoracic scoliosis the correction effect was 36% (n = 41) and in double major curve patterns 50% (n = 22). The correction effect was affected in a slightly negative way due to age (r = -0,24; p = 0,014), negatively with the Risser stage (-0,29; p = 0,0096) and correlated negatively with the Cobb angle measured before treatment (r = -0,43; p < 0,0001).</p> <p>Conclusions</p> <p>The use of the ChĂȘneau lightℱ brace leads to correction effects above average when compared to correction effects of other braces described in literature. The reduction of material seems to increase patient's comfort and reduces the stress patients may suffer from whilst in the brace.</p> <p>80% of the adolescent population of scoliosis patients can be braced with the ChĂȘneau lightℱ brace. In certain patterns of curvature and in the younger population with an age of less than 11 years, other approaches have to be used, such as plaster based bracing or the application of CAD/CAM based orthoses.</p

    Mass Correlation Between Real Vehicle and Vehicle Laboratory Simulation Model

    Get PDF
    The problem how easily to scale down real object of simulation to laboratory simulation model, thus simplify equations to the extent of only one scaling factor that correlates between the real object and model, is always present in laboratory simulations. This paper presents a simple way to scale down real vehicle to the model level and also how to determine the acceptable range of real vehicle that can be simulated by laboratory model. The problem started when all field measurements on real vehicle ended, and laboratory simulation model, smaller than real vehicle, had to simulate that vehicle (drive machine had less rated power than a vehicle engine, and a load machine can create less load that of a real vehicle)

    Treatment of chronic low back pain in patients with spinal deformities using a sagittal re-alignment brace

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>For adult scoliosis patients with chronic low back pain bracing is initially indicated before spinal surgery is considered. Until recently there has been a lack of research into the effect upon pain reductions in the mid and long-term. Promising results have been documented in short-term studies for the application of a sagittal re-alignment brace in patients with spinal deformities and along with pain; however mid-term and long-term results are not yet available. The purpose of this study is to investigate the mid-term effects of this brace with respect to pain control.</p> <p>Materials and methods</p> <p>67 patients (58 females and 9 males) with chronic low back pain (> 24 months) and the diagnosis of scoliosis or hyperkyphosis were treated with a sagittal re-alignment brace (physio-logic braceℱ) between January 2006 and July 2007. The indication for this kind of brace treatment was derived from a positive sagittal re-alignment test (SRT) and the exclusion of successful conservative treatment during the last 24 months. The aim of this type of conservative intervention was to avoid surgery for chronic low back pain.</p> <p>Results</p> <p>The average pain intensity was measured on the Roland and Morris VRS (5 steps) before treatment. This was 3.3 (t1), at the time of brace adjustment it was 2.7 (t2) and after at an average observation time of 18 months it was 2.0 (t3). The differences were highly significant in the Wilcoxon test.</p> <p>Discussion</p> <p>Short-term measurements showed that a significant pain reduction is possible in chronic postural low back pain using a sagittal re-alignment brace inducing lumbar re-lordosation. In a preliminary report at adjustment (t2), highly significant improvements of pain intensity have also been demonstrated. At 6 months of treatment however, no improvement was measured. The improvement of the mid-term effects (18 months) found in this study compared to the preliminary report may be due to the changed approach to compliance: whilst the bracing standard was not changed; the patients in this study were obligated to wear the brace for a minimum of 20 hrs per day for the first 6 months of treatment.</p> <p>Conclusion</p> <p>The effect of the sagittal re-alignment brace leads to promising short-term improvements in patients with chronic low back pain and spinal deformities. Contrary to unspecific orthoses, which after a short period without persistent pain reduction are omitted by the patients, the sagittal re-alignment brace (physio-logicℱ brace) leads to an effective reduction of pain intensity in mid-term even in patients who have stopped brace treatment after the initial 6 months of treatment. In conservative treatment of chronic low back pain specific approaches such as the sagittal re-alignment brace are indicated prior to considering the surgical options.</p

    In Silico Study of Avocado (Persea americana Mill.) Seed Compounds Against PBP2a Receptor on Staphylococcus aureus

    Get PDF
    The nosocomial infection causes 1,4 million mortality every day in the world. International Nosocomial Infection Control Consortium (INICC) data shows that 84,4% nosocomial infection is caused by S. aureus that can cause skin infection. Avocado (P. americana) seed has been reported as an antibacterial agent and used for dermatological applications. This research was aimed to know the potential of antibacterial activity of ethanolic extract of avocado seed in silico study. The in silico test used molecular docking method with PyRx software between PBP2a as receptor and phytochemical compounds in avocado seed as a ligand. The result showed that rutin compound had the best potential to bind PBP2a (binding affinity: -18,2 kcal/mol). Thus, phytochemical active compounds in avocado seed can be recommended as an antibacterial drug and can increase the number of fibroblast cells caused by S. aureus

    Correction effects of the ScoliOlogiC(Âź )„ChĂȘneau light" brace in patients with scoliosis

    Get PDF
    BACKGROUND: Different bracing concepts are used today for the treatment of scoliosis. The plaster cast method worldwide seems to be the most practiced technique at the moment. CAD (Computer Aided Design) systems are on the market which allow brace adjustments without plaster. The latest development however, is the use of the ScoliOlogiCℱ off the shelf system enabling the orthopaedic technician to construct a light brace for scoliosis correction from a variety of pattern specific shells to be connected to an anterior and a posterior upright. This „ChĂȘneau light" brace, developed according to the ChĂȘneau principle, promises a reduced impediment of quality of life in the brace. However, material reduction should not result in reduced effectiveness. Therefore the primary correction effect in the „ChĂȘneau light" brace has been evaluated and compared with that of other braces used today. METHODS: The correction effects of the first 81 patients (main diagnosis Adolescent Idiopathic Scoliosis (AIS) [n = 64] or Early Onset Scoliosis (EOS) [n = 15]), treated according to the principle of the „ChĂȘneau light" brace were evaluated after an average treatment time of 6 weeks by a full-body X-ray made in the standing position whilst wearing the brace and compared with the last X-ray before bracing. The average curvature angle of the whole group was 35,6°, the average age was 12,9 years (SD 1,9), average Risser sign was 1,3 (SD 1,5), average Tanner rating 2,75 (SD 0,7). RESULTS: The Cobb angle in the whole group was reduced by an average of 16,4°, which corresponds to a correction effect of 51%. The differences were highly significant in the T-test (T = 17,4; p < 0,001). The best correction effects reported in literature so far are about 40% in two different studies. The correction effect was highest in lumbar and thoracolumbar curve pattern (62 %; n = 18). In thoracic scoliosis the correction effect was 36 % (n = 41) and in double major curve pattern 50 % (n = 22). The correction effect correlated slightly negative with age (r = -0,24; p = 0,014), negatively with the Risser stage (-0,29; p = 0,0096) and correlated negatively with the Cobb angle measured before treatment (r = -0,43; p < 0,0001). CONCLUSION: The use of the „ChĂȘneau light" brace leads to correction effects above average when compared to the correction effects of other braces described in literature. The reduction of material seems to affect the desired correction in a positive way

    Efficacy and safety of argatroban in patients with acute respiratory distress syndrome and extracorporeal lung support

    Get PDF
    Background Extracorporeal membrane oxygenation (ECMO) or pumpless extracorporeal lung assist (pECLA) requires effective anticoagulation. Knowledge on the use of argatroban in patients with acute respiratory distress syndrome (ARDS) undergoing ECMO or pECLA is limited. Therefore, this study assessed the feasibility, efficacy and safety of argatroban in critically ill ARDS patients undergoing extracorporeal lung support. Methods This retrospective analysis included ARDS patients on extracorporeal lung support who received argatroban between 2007 and 2014 in a single ARDS referral center. As controls, patients who received heparin were matched for age, sex, body mass index and severity of illness scores. Major and minor bleeding complications, thromboembolic events, administered number of erythrocyte concentrates, thrombocytes and fresh-frozen plasmas were assessed. The number of extracorporeal circuit systems and extracorporeal lung support cannulas needed due to clotting was recorded. Also assessed was the efficacy to reach the targeted activated partial thromboplastin time (aPTT) in the first consecutive 14 days of therapy, and the controllability of aPTT values is within a therapeutic range of 50–75 s. Fisher’s exact test, Mann–Whitney U tests, Friedman tests and multivariate nonparametric analyses for longitudinal data (MANOVA; Brunner’s analysis) were applied where appropriate. Results Of the 535 patients who met the inclusion criteria, 39 receiving argatroban and 39 matched patients receiving heparin (controls) were included. Baseline characteristics were similar between the two groups, including severity of illness and organ failure scores. There were no significant differences in major and minor bleeding complications. Rates of thromboembolic events were generally low and were similar between the two groups, as were the rates of transfusions required and device-associated complications. The controllability of both argatroban and heparin improved over time, with a significantly increasing probability to reach the targeted aPTT corridor over the first days (p < 0.001). Over time, there were significantly fewer aPTT values below the targeted aPTT goal in the argatroban group than in the heparin group (p < 0.05). Both argatroban and heparin reached therapeutic aPTT values for adequate application of extracorporeal lung support. Conclusions Argatroban appears to be a feasible, effective and safe anticoagulant for critically ill ARDS patients undergoing extracorporeal lung support

    Brace related stress in scoliosis patients – Comparison of different concepts of bracing

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The BSSQbrace questionnaire has been shown to be reliable with good internal consistency and reproducibility estimating the stress scoliosis patients have whilst wearing their brace. Eight questions are provided focussing on this topic. A max. score of 24 can be achieved (from 0 for most stress to 24 for no stress). The subdivision of the score values is: 0–8 (strong stress), 9–16 (medium stress) and 17–24 (little stress).</p> <p>Study design</p> <p>Two BSSQbrace questionnaires have been posted to 65 patients under brace treatment from our Cheneau light data base. All patients had another kind of brace prior to the Cheneau light. The patients have been asked to rate their stress level using one questionnaire for the current brace and the other for the previous one.</p> <p>Results</p> <p>63 Patients (59 girls and 4 boys) returned their fully completed questionnaires (average age 13,6 years, average Cobb angle 43,7 degrees). Stress level in the previous brace was 11,04 and in the Cheneau light(r) 13,87. The differences were highly significant in the t-test; t = -4,67; p < 0,001.</p> <p>Conclusion</p> <p>The use of the Cheneau light<sup>¼ </sup>brace leads to reduced stress and/or impairment for the patients under treatment compared to heavier brace models used so far.</p

    EcoCyc: fusing model organism databases with systems biology.

    Get PDF
    EcoCyc (http://EcoCyc.org) is a model organism database built on the genome sequence of Escherichia coli K-12 MG1655. Expert manual curation of the functions of individual E. coli gene products in EcoCyc has been based on information found in the experimental literature for E. coli K-12-derived strains. Updates to EcoCyc content continue to improve the comprehensive picture of E. coli biology. The utility of EcoCyc is enhanced by new tools available on the EcoCyc web site, and the development of EcoCyc as a teaching tool is increasing the impact of the knowledge collected in EcoCyc

    Clinical validation of a smartphone-based adapter for optic disc imaging in Kenya

    Get PDF
    Visualization and interpretation of the optic nerve and retina are essential parts of most physical examinations. To design and validate a smartphone-based retinal adapter enabling image capture and remote grading of the retina. This validation study compared the grading of optic nerves from smartphone images with those of a digital retinal camera. Both image sets were independently graded at Moorfields Eye Hospital Reading Centre. Nested within the 6-year follow-up (January 7, 2013, to March 12, 2014) of the Nakuru Eye Disease Cohort in Kenya, 1460 adults (2920 eyes) 55 years and older were recruited consecutively from the study. A subset of 100 optic disc images from both methods were further used to validate a grading app for the optic nerves. Data analysis was performed April 7 to April 12, 2015. Vertical cup-disc ratio for each testwas compared in terms of agreement (Bland-Altman and weighted Îș) and test-retest variability. A total of 2152 optic nerve images were available from both methods (also 371 from the reference camera but not the smartphone, 170 from the smartphone but not the reference camera, and 227 from neither the reference camera nor the smartphone). Bland-Altman analysis revealed a mean difference of 0.02 (95%CI, −0.21 to 0.17) and a weighted Îș coefficient of 0.69 (excellent agreement). The grades of an experienced retinal photographer were compared with those of a lay photographer (no health care experience before the study), and no observable difference in image acquisition quality was found. Nonclinical photographers using the low-cost smartphone adapter were able to acquire optic nerve images at a standard that enabled independent remote grading of the images comparable to those acquired using a desktop retinal camera operated by an ophthalmic assistant. The potential for task shifting and the detection of avoidable causes of blindness in the most at-risk communities makes this an attractive public health intervention
    • 

    corecore