890 research outputs found

    Synchronous vs. asynchronous dynamics of diffusion-controlled reactions

    Full text link
    An analytical method based on the classical ruin problem is developed to compute the mean reaction time between two walkers undergoing a generalized random walk on a 1d lattice. At each time step, either both walkers diffuse simultaneously with probability pp (synchronous event) or one of them diffuses while the other remains immobile with complementary probability (asynchronous event). Reaction takes place through same site occupation or position exchange. We study the influence of the degree of synchronicity pp of the walkers and the lattice size NN on the global reaction's efficiency. For odd NN, the purely synchronous case (p=1p=1) is always the most effective one, while for even NN, the encounter time is minimized by a combination of synchronous and asynchronous events. This new parity effect is fully confirmed by Monte Carlo simulations on 1d lattices as well as for 2d and 3d lattices. In contrast, the 1d continuum approximation valid for sufficiently large lattices predicts a monotonic increase of the efficiency as a function of pp. The relevance of the model for several research areas is briefly discussed.Comment: 21 pages (including 12 figures and 4 tables), uses revtex4.cls, accepted for publication in Physica

    Effective thermodynamics of strongly coupled qubits

    Full text link
    Interactions between a quantum system and its environment at low temperatures can lead to violations of thermal laws for the system. The source of these violations is the entanglement between system and environment, which prevents the system from entering into a thermal state. On the other hand, for two-state systems, we show that one can define an effective temperature, placing the system into a `pseudo-thermal' state where effective thermal laws are upheld. We then numerically explore these assertions for an n-state system inspired by the spin-boson environment.Comment: 9 pages, 3 figure

    Development and Validation of a Smartphone-Based Visual Acuity Test (Peek Acuity) for Clinical Practice and Community-Based Fieldwork.

    Get PDF
    IMPORTANCE: Visual acuity is the most frequently performed measure of visual function in clinical practice and most people worldwide living with visual impairment are living in low- and middle-income countries. OBJECTIVE: To design and validate a smartphone-based visual acuity test that is not dependent on familiarity with symbols or letters commonly used in the English language. DESIGN, SETTING, AND PARTICIPANTS: Validation study conducted from December 11, 2013, to March 4, 2014, comparing results from smartphone-based Peek Acuity to Snellen acuity (clinical normal) charts and the Early Treatment Diabetic Retinopathy Study (ETDRS) logMAR chart (reference standard). This study was nested within the 6-year follow-up of the Nakuru Eye Disease Cohort in central Kenya and included 300 adults aged 55 years and older recruited consecutively. MAIN OUTCOMES AND MEASURES: Outcome measures were monocular logMAR visual acuity scores for each test: ETDRS chart logMAR, Snellen acuity, and Peek Acuity. Peek Acuity was compared, in terms of test-retest variability and measurement time, with the Snellen acuity and ETDRS logMAR charts in participants' homes and temporary clinic settings in rural Kenya in 2013 and 2014. RESULTS: The 95% CI limits for test-retest variability of smartphone acuity data were ±0.033 logMAR. The mean differences between the smartphone-based test and the ETDRS chart and the smartphone-based test and Snellen acuity data were 0.07 (95% CI, 0.05-0.09) and 0.08 (95% CI, 0.06-0.10) logMAR, respectively, indicating that smartphone-based test acuities agreed well with those of the ETDRS and Snellen charts. The agreement of Peek Acuity and the ETDRS chart was greater than the Snellen chart with the ETDRS chart (95% CI, 0.05-0.10; P = .08). The local Kenyan community health care workers readily accepted the Peek Acuity smartphone test; it required minimal training and took no longer than the Snellen test (77 seconds vs 82 seconds; 95% CI, 71-84 seconds vs 73-91 seconds, respectively; P = .13). CONCLUSIONS AND RELEVANCE: The study demonstrated that the Peek Acuity smartphone test is capable of accurate and repeatable acuity measurements consistent with published data on the test-retest variability of acuities measured using 5-letter-per-line retroilluminated logMAR charts

    Short Term High-Repetition Back Squat Protocol Does Not Improve 5-km Run Performance

    Get PDF
    International Journal of Exercise Science 13(7): 1770-1782, 2020. The purpose of this study was to evaluate the hypothesis that a novel high-repetition, low-resistance back squat training protocol, designed to stimulate high-intensity interval training, improves 5-km run performance. Fifteen runners [4 male, 11 female; 150 + minutes of endurance exercise/week; age = 22.7 ± 2.0 y; 21.5 ± 2.2 kg/m2 BMI] in this single-group test-retest design completed two weeks of back squats consisting of three sets of 15-24 repetitions at 60% of estimated one-repetition max (1RM), three times per week (1-2 days of rest between sessions). Outcome tests included a 5-km outdoor timed run, laboratory indirect calorimetry to quantify substrate oxidation rates during steady-state submaximal exercise (60% and 70% heart rate max (HRmax)), and estimated 1RM for back squats. Back squat estimated 1RM increased by 20% (58.3 ± 18.5 to 70.2 ± 16.7 kg, P \u3c 0.001). However, 5-km run times due to the back squat protocol did not significantly change (Pre-Squats: 23.9 ± 5.0 vs. Post-Squats: 23.7 ± 4.3 minutes, P = 0.71). Likewise, the squat training program did not significantly alter carbohydrate or lipid oxidation rates during steady-state submaximal exercise at 60% or 70% of HRmax (P values ranged from 0.36 - 0.99). Short term high-repetition back squat training does not appear to impact 5-km run performance or substrate utilization during submaximal exercise

    Emotion and performance

    Get PDF
    The study of emotions in organizational settings has attained considerable prominence in recent years, but I critical issue remains unresolved. This is the relationship between emotion and performance. in this special issue, 5 articles address this topic from a variety of viewpoints. Two are theoretical essays that deal, respectively, with emotion and creativity and the relationships between individual and team performance. Three are empirical studies that canvass the emotion-performance nexus across levels of analysis: within person, between persons, and in groups. Between them, the 5 articles present a strong case for the nexus of emotions and performance, but, more important, they provide a platform for potentially fruitful future research in this burgeoning area

    Biventricular adaptation to volume overload in mice with aortic regurgitation

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Aortic valve regurgitation is usually caused by impaired coaptation of the aortic valve cusps during diastole. Hypercholesterolemia produces aortic valve lipid deposition, fibrosis, and calcification in both mice and humans, which could impair coaptation of cusps. However, a link between hypercholesterolemia and aortic regurgitation has not been established in either species. The purpose of this study was to ascertain the prevalence of aortic regurgitation in hypercholesterolemic mice and to determine its impact on the left and right ventricles.</p> <p>Methods and Results</p> <p>Eighty <it>Ldlr</it><sup>-/-</sup>/<it>Apob</it><sup>100/100</sup>/<it>Mttp</it><sup>fl/fl</sup>/Mx1Cre<sup>+/+ </sup>("Reversa") hypercholesterolemic mice and 40 control mice were screened for aortic regurgitation (AR) with magnetic resonance imaging at age 7.5 months. The prevalence of AR was 40% in Reversa mice, with moderate or severe regurgitation (AR<sup>+</sup>) in 19% of mice. In control mice, AR prevalence was 13% (p = 0.004 <it>vs</it>. Reversa), and was invariably trace or mild in severity. In-depth evaluation of cardiac response to volume overload was performed in 12 AR-positive and 12 AR-negative Reversa mice. Regurgitant fraction was 0.34 ± 0.04 in AR-positive <it>vs</it>. 0.02 ± 0.01 in AR-negative (mean ± SE; p < 0.001). AR-positive mice had significantly increased left ventricular end-diastolic volume and mass and reduced ejection fraction in both ventricles. When left ventricular ejection fraction fell below 0.60 in AR-positive (<it>n </it>= 7) mice, remodeling occurred and right ventricular systolic function progressively worsened.</p> <p>Conclusion</p> <p>Hypercholesterolemia causes aortic valve regurgitation with moderate prevalence in mice. When present, aortic valve regurgitation causes volume overload and pathological remodeling of both ventricles.</p

    Effects of deep sedation or general anesthesia on cardiac function in mice undergoing cardiovascular magnetic resonance

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Genetically engineered mouse models of human cardiovascular disease provide an opportunity to understand critical pathophysiological mechanisms. Cardiovascular magnetic resonance (CMR) provides precise reproducible assessment of cardiac structure and function, but, in contrast to echocardiography, requires that the animal be immobilized during image acquisition. General anesthetic regimens yield satisfactory images, but have the potential to significantly perturb cardiac function. The purpose of this study was to assess the effects of general anesthesia and a new deep sedation regimen, respectively, on cardiac function in mice as determined by CMR, and to compare them to results obtained in mildly sedated conscious mice by echocardiography.</p> <p>Results</p> <p>In 6 mildly sedated normal conscious mice assessed by echo, heart rate was 615 ± 25 min<sup>-1 </sup>(mean ± SE) and left ventricular ejection fraction (LVEF) was 0.94 ± 0.01. In the CMR studies of normal mice, heart rate was slightly lower during deep sedation with morphine/midazolam (583 ± 30 min<sup>-1</sup>), but the difference was not statistically significant. General anesthesia with 1% inhaled isoflurane significantly depressed heart rate (468 ± 7 min<sup>-1</sup>, p < 0.05 vs. conscious sedation). In 6 additional mice with ischemic LV failure, trends in heart rate were similar, but not statistically significant. In normal mice, deep sedation depressed LVEF (0.79 ± 0.04, p < 0.05 compared to light sedation), but to a significantly lesser extent than general anesthesia (0.60 ± 0.04, p < 0.05 vs. deep sedation).</p> <p>In mice with ischemic LV failure, ejection fraction measurements were comparable when performed during light sedation, deep sedation, and general anesthesia, respectively. Contrast-to-noise ratios were similar during deep sedation and during general anesthesia, indicating comparable image quality. Left ventricular mass measurements made by CMR during deep sedation were nearly identical to those made during general anesthesia (r<sup>2 </sup>= 0.99, mean absolute difference < 4%), indicating equivalent quantitative accuracy obtained with the two methods. The imaging procedures were well-tolerated in all mice.</p> <p>Conclusion</p> <p>In mice with normal cardiac function, CMR during deep sedation causes significantly less depression of heart rate and ejection fraction than imaging during general anesthesia with isoflurane. In mice with heart failure, the sedation/anesthesia regimen had no clear impact on cardiac function. Deep sedation and general anesthesia produced CMR with comparable image quality and quantitative accuracy.</p

    Macroscopic Quantum Tunneling of Ferromagnetic Domain Walls

    Full text link
    Quantum tunneling of domain walls out of an impurity potential in a mesoscopic ferromagnetic sample is investigated. Using improved expressions for the domain wall mass and for the pinning potential, we find that the cross-over temperature between thermal activation and quantum tunneling is of a different functional form than found previously. In materials like Ni or YIG, the crossover temperatures are around 5 mK. We also find that the WKB exponent is typically two orders of magnitude larger than current estimates. The sources for these discrepancies are discussed, and precise estimates for the transition from three-dimensional to one-dimensional magnetic behavior of a wire are given. The cross-over temperatures from thermal to quantum transitions and tunneling rates are calculated for various materials and sample sizes.Comment: 10 pages, 2 postscript figures, REVTe

    Antimicrobial Microwebs of DNA–Histone Inspired from Neutrophil Extracellular Traps

    Full text link
    Neutrophil extracellular traps (NETs) are decondensed chromatin networks released by neutrophils that can trap and kill pathogens but can also paradoxically promote biofilms. The mechanism of NET functions remains ambiguous, at least in part, due to their complex and variable compositions. To unravel the antimicrobial performance of NETs, a minimalistic NET‐like synthetic structure, termed “microwebs,” is produced by the sonochemical complexation of DNA and histone. The prepared microwebs have structural similarity to NETs at the nanometer to micrometer dimensions but with well‐defined molecular compositions. Microwebs prepared with different DNA to histone ratios show that microwebs trap pathogenic Escherichia coli in a manner similar to NETs when the zeta potential of the microwebs is positive. The DNA nanofiber networks and the bactericidal histone constituting the microwebs inhibit the growth of E. coli. Moreover, microwebs work synergistically with colistin sulfate, a common and a last‐resort antibiotic, by targeting the cell envelope of pathogenic bacteria. The synthesis of microwebs enables mechanistic studies not possible with NETs, and it opens new possibilities for constructing biomimetic bacterial microenvironments to better understand and predict physiological pathogen responses.Microwebs with bacteria trapping and killing functions are designed to mimic neutrophil extracellular traps—an immune defense weapon to fight against invading pathogens. The composition–structure–function relationship of the synthetic structure is discussed, and the collaborative action between microwebs and antibiotics allows better elimination of pathogenic bacteria, Escherichia coli.Peer Reviewedhttps://deepblue.lib.umich.edu/bitstream/2027.42/149216/1/adma201807436-sup-0001-S1.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/149216/2/adma201807436_am.pdfhttps://deepblue.lib.umich.edu/bitstream/2027.42/149216/3/adma201807436.pd
    • 

    corecore