504 research outputs found

    Shaped nozzles for cryogenic buffer gas beam sources

    Get PDF
    Cryogenic buffer gas beams are important sources of cold molecules. In this work we explore the use of a converging-diverging nozzle with a buffer-gas beam. We find that, under appropriate circumstances, the use of a nozzle can produce a beam with improved collimation, lower transverse temperatures, and higher fluxes per solid angle

    Estimating the Cost of Health Care-Associated Infections: Mind Your p's and q's

    Get PDF
    Monetary valuations of the economic cost of health care-associated infections (HAIs) are important for decision making and should be estimated accurately. Erroneously high estimates of costs, designed to jolt decision makers into action, may do more harm than good in the struggle to attract funding for infection control. Expectations among policy makers might be raised, and then they are disappointed when the reduction in the number of HAIs does not yield the anticipated cost saving. For this article, we critically review the field and discuss 3 questions. Why measure the cost of an HAI? What outcome should be used to measure the cost of an HAI? What is the best method for making this measurement? The aim is to encourage researchers to collect and then disseminate information that accurately guides decisions about the economic value of expanding or changing current infection control activitie

    Pressure dependence of the Boson peak in glassy As2S3 studied by Raman Scattering

    Full text link
    A detailed pressure-dependence study of the low-energy excitations of glassy As2S3 is reported over a wide pressure range, up to 10 GPa. The spectral features of Boson peak are analysed as a function of pressure. Pressure effects on the Boson peak are manifested as an appreciable shift of its frequency to higher values, a suppression of its intensity, as well as a noticeable change of its asymmetry leading to a more symmetric shape at high pressures. The pressure-induced Boson peak frequency shift agrees very well with the predictions of the soft potential model over the whole pressure range studied. As regards the pressure dependence of the Boson peak intensity, the situation is more complicated. It is proposed that in order to reach proper conclusions the corresponding dependence of the Debye density of states must also be considered. Employing a comparison of the low energy modes of the crystalline counterpart of As2S3 as well as the experimental data concerning the pressure dependencies of the Boson peak frequency and intensity, structural or glass-to-glass transition seems to occur at the pressure ~4 GPa related to a change of local structure. Finally, the pressure-induced shape changes of the Boson peak can be traced back to the very details of the excess (over the Debye contribution) vibrational density of states.Comment: To appear in J. Non-Cryst. Solids (Proceedings of the 5th IDMRCS, Lille, July 2005

    Using uncrewed aerial vehicles for identifying the extent of invasive phragmites australis in treatment areas enrolled in an adaptive management program

    Get PDF
    Higher spatial and temporal resolutions of remote sensing data are likely to be useful for ecological monitoring efforts. There are many different treatment approaches for the introduced European genotype of Phragmites australis, and adaptive management principles are being integrated in at least some long-term monitoring efforts. In this paper, we investigated how natural color and a smaller set of near-infrared (NIR) images collected with low-cost uncrewed aerial vehicles (UAVs) could help quantify the aboveground effects of management efforts at 20 sites enrolled in the Phragmites Adaptive Management Framework (PAMF) spanning the coastal Laurentian Great Lakes region. We used object-based image analysis and field ground truth data to classify the Phragmites and other cover types present at each of the sites and calculate the percent cover of Phragmites, including whether it was alive or dead, in the UAV images. The mean overall accuracy for our analysis with natural color data was 91.7% using four standardized classes (Live Phragmites, Dead Phragmites, Other Vegetation, Other Non-vegetation). The Live Phragmites class had a mean user’s accuracy of 90.3% and a mean producer’s accuracy of 90.1%, and the Dead Phragmites class had a mean user’s accuracy of 76.5% and a mean producer’s accuracy of 85.2% (not all classes existed at all sites). These results show that UAV-based imaging and object-based classification can be a useful tool to measure the extent of dead and live Phragmites at a series of sites undergoing management. Overall, these results indicate that UAV sensing appears to be a useful tool for identifying the extent of Phragmites at management sites

    Nutrient Sensing by Tas1R Proteins is Required for Normal Bone Resorption

    Get PDF
    Current therapies for low bone mass consist of inhibiting osteoclast activity or increasing the PTH or Wnt signaling pathways. These approaches have significant drawbacks that limit their use in specific patient populations and/or negatively impact patient compliance with therapy. Developing improved therapies requires diversifying our understanding of the mechanisms underlying postnatal bone remodeling by examining lesser-known signaling pathways. One such pathway is the taste receptor type 1 (TAS1R) family of heterotrimeric G protein-coupled receptors, which participates in monitoring energy and nutrient status. Previous work reported that global deletion of TAS1R member 3 (TAS1R3), which is a bi-functional protein that recognizes amino acids or sweet molecules when dimerized with TAS1R member 1 (TAS1R1) or TAS1R member 2 (TAS1R2), respectively, leads to increased cortical bone mass. Here, we corroborate the increased thickness of cortical bone in Tas1R3 knockout mice and confirm that Tas1R3 is expressed in the bone environment. Quantification of serum bone turnover markers indicate that this phenotype is likely due to uncoupled bone remodeling, with levels of the bone resorption marker CTx being reduced greater than 60% in Tas1R3 mutant mice; no changes were observed in levels of the bone formation marker PINP. Consistent with this, Tas1R3 and its putative signaling partner Tas1R2 are expressed in primary osteoclasts and RAW264.7 cells following RANKL-mediated differentiation. These findings suggest that osteoclast function and/or differentiation may be altered in the absence of Tas1R3 expression. To test this, we quantified bone-specific expression of Rankl and determined the Rankl:Opg ratio; no differences were observed between control and Tas1R3 knockout mice in these analyses. In vitro studies examining further downstream effectors of TAS1R2:3 in response to saccharin and receptor antagonist gurmarin are currently underway. Collectively, our findings provide the first demonstration that nutrient monitoring by TAS1R3 is essential for normal bone resorption in vivo

    Cost-effectiveness of left ventricular assist devices (LVADs) for patients with advanced heart failure : analysis of the British NHS Bridge to Transplant (BTT) program

    Get PDF
    Background: A previous cost-effectiveness analysis showed that bridge to transplant (BTT) with early design left ventricular assist devices (LVADs) for advanced heart failure was more expensive than medical management while appearing less beneficial. Older LVADs were pulsatile, but current second and third generation LVADs are continuous flow pumps. This study aimed to estimate comparative cost-effectiveness of BTT with durable implantable continuous flow LVADs compared to medical management in the British NHS. Methods and results: A semi-Markov multi-state economic model was built using NHS costs data and patient data in the British NHS Blood and Transplant Database (BTDB). Quality-adjusted life years (QALYs) and incremental costs per QALY were calculated for patients receiving LVADs compared to those receiving inotrope supported medical management. LVADs cost £80,569 (127,887)at2011pricesanddeliveredgreaterbenefitthanmedicalmanagement.Theestimatedprobabilisticincrementalcost−effectivenessratio(ICER)was£53,527(127,887) at 2011 prices and delivered greater benefit than medical management. The estimated probabilistic incremental cost-effectiveness ratio (ICER) was £53,527 (84,963)/QALY (95%CI: £31,802–£94,853; 50,479–50,479–150,560) (over a lifetime horizon). Estimates were sensitive to choice of comparator population, relative likelihood of receiving a heart transplant, time to transplant, and LVAD costs. Reducing the device cost by 15% decreased the ICER to £50,106 ($79,533)/QALY. Conclusions: Durable implantable continuous flow LVADs deliver greater benefits at higher costs than medical management in Britain. At the current UK threshold of £20,000 to £30,000/QALY LVADs are not cost effective but the ICER now begins to approach that of an intervention for end of life care recently recommended by the British NHS. Cost-effectiveness estimates are hampered by the lack of randomized trials

    Cost-effectiveness of left ventricular assist devices (LVADs) for patients with advanced heart failure : analysis of the British NHS Bridge to Transplant (BTT) program

    Get PDF
    Background: A previous cost-effectiveness analysis showed that bridge to transplant (BTT) with early design left ventricular assist devices (LVADs) for advanced heart failure was more expensive than medical management while appearing less beneficial. Older LVADs were pulsatile, but current second and third generation LVADs are continuous flow pumps. This study aimed to estimate comparative cost-effectiveness of BTT with durable implantable continuous flow LVADs compared to medical management in the British NHS. Methods and results: A semi-Markov multi-state economic model was built using NHS costs data and patient data in the British NHS Blood and Transplant Database (BTDB). Quality-adjusted life years (QALYs) and incremental costs per QALY were calculated for patients receiving LVADs compared to those receiving inotrope supported medical management. LVADs cost £80,569 (127,887)at2011pricesanddeliveredgreaterbenefitthanmedicalmanagement.Theestimatedprobabilisticincrementalcost−effectivenessratio(ICER)was£53,527(127,887) at 2011 prices and delivered greater benefit than medical management. The estimated probabilistic incremental cost-effectiveness ratio (ICER) was £53,527 (84,963)/QALY (95%CI: £31,802–£94,853; 50,479–50,479–150,560) (over a lifetime horizon). Estimates were sensitive to choice of comparator population, relative likelihood of receiving a heart transplant, time to transplant, and LVAD costs. Reducing the device cost by 15% decreased the ICER to £50,106 ($79,533)/QALY. Conclusions: Durable implantable continuous flow LVADs deliver greater benefits at higher costs than medical management in Britain. At the current UK threshold of £20,000 to £30,000/QALY LVADs are not cost effective but the ICER now begins to approach that of an intervention for end of life care recently recommended by the British NHS. Cost-effectiveness estimates are hampered by the lack of randomized trials
    • …
    corecore