15 research outputs found

    Multiabsorber Transition-Edge Sensors for X-Ray Astronomy

    Get PDF
    We are developing arrays of position-sensitive microcalorimeters for future x-ray astronomy applications. These position-sensitive devices commonly referred to as hydras consist of multiple x-ray absorbers, each with a different thermal coupling to a single-transition-edge sensor microcalorimeter. Their development is motivated by a desire to achieve very large pixel arrays with some modest compromise in performance. We report on the design, optimization, and first results from devices with small pitch pixels (<75 m) being developed for a high-angular and energy resolution imaging spectrometer for Lynx. The Lynx x-ray space telescope is a flagship mission concept under study for the National Academy of Science 2020 decadal survey. Broadband full-width-half-maximum (FWHM) resolution measurements on a 9-pixel hydra have demonstrated E(FWHM) = 2.23 0.14 eV at Al-K, E(FWHM) = 2.44 0.29 eV at Mn-K, and E(FWHM) = 3.39 0.23 eV at Cu-K. Position discrimination is demonstrated to energies below <1 keV and the device performance is well-described by a finite-element model. Results from a prototype 20-pixel hydra with absorbers on a 50-m pitch have shown E(FWHM) = 3.38 0.20 eV at Cr-K1. We are now optimizing designs specifically for Lynx and extending the number of absorbers up to 25/hydra. Numerical simulation suggests optimized designs could achieve 3 eV while being compatible with the bandwidth requirements of the state-of-the art multiplexed readout schemes, thus making a 100,000 pixel microcalorimeter instrument a realistic goal

    A Fabry-Perot Imaging Search for Lyman-alpha Emission in Quasar Absorbers at z ~ 2.4

    Full text link
    We have carried out a deep narrow-band imaging survey of six fields with heavy-element quasar absorption lines, using the Goddard Fabry-Perot (FP) system at the Apache Point Observatory (APO) 3.5-meter telescope. The aim of these observations was to search for redshifted Ly-α\alpha emission from the galaxies underlying the absorbers at z=2.32.5z = 2.3-2.5 and their companion galaxies. The 3 σ\sigma sensitivity levels ranged between 1.9×10171.9 \times 10^{-17} and 5.4×10175.4 \times 10^{-17} erg s1^{-1} cm2^{-2} in observed-frame Ly-α\alpha flux. No significant Ly-α\alpha emitters were detected at >3σ> 3 \sigma level. The absence of significant Ly-α\alpha emission implies limits on the star formation rate (SFR) of 0.9-2.7 MM_{\odot} yr1^{-1} per 2-pixel x 2-pixel region, if no dust attenuation is assumed. We compare our results with those from other emission-line studies of absorber fields and with predictions for global average SFR based on the models of cosmic chemical evolution. Our limits are among the tightest existing constraints on Ly-α\alpha emission from galaxies in absorber fields, but are consistent with many other studies. In the absence of dust attenuation, these studies suggest that SFRs in a large fraction of objects in the absorber fields may lie below the global mean SFR. However, it is possible that dust attenuation is responsible for the low emission line fluxes in some objects. It is also possible that the star-forming regions are compact and at smaller angular separations from the quasar than the width of our point spread function and, get lost in the quasar emission. We outline future observations that could help to distinguish between the various possibilities.Comment: Accepted for Publication in the Astrophysical Journal, 32 pages, 8 figures. NOTE: 25 of the 29 subpanels in the figures are included here at lower resolution to keep the astroph submission size within allowed limits. Please see http://boson.physics.sc.edu/~kulkarni/fpimaging.html for a pdf file of the complete paper including all subpanels of all figures in the original higher resolutio

    Performance of an X-Ray Microcalorimeter with a 240 Micron Absorber and a 50 Micron TES Bilayer

    Get PDF
    We have been developing superconducting transition-edge sensor (TES) microcalorimeters for a variety of potential astrophysics missions, including Athena. The X-ray Integral Field Unit (X-IFU) instrument on this mission requires close-packed pixels on a 0.25 mm pitch, and high quantum efficiency between 0.2 and 12 keV. The traditional approach within our group has been to use square TES bilayers on molybdenum and gold that are between 100 and 140 microns in size, deposited on silicon nitride membranes to provide a weak thermal conductance to a 50 mK heat bath temperature. It has been shown that normal metal stripes on top of the bilayer are needed to keep the unexplained noise at a level consistent with the expected based upon estimates for the non-equilibrium non-linear Johnson noise.In this work we describe a new approach in which we use a square TES bilayer that is 50 microns in size. While the weak link effect is much stronger in this size of TES, we have found that excellent spectral performance can be achieved without the need for any normal metal strips on top of the TES. A spectral performance of 1.58 eV at 6 KeV has been achieved, the best resolution seen in any of our devices with this pixel size. The absence of normal metal stripes has led to more uniform transition shapes, and more reliable excellent spectral performance. The smaller TES size has meant that that the thermal conductance to the heat bath, determined by the perimeter length of the TES and the membrane thickness, is lower than on previous devices, and thus has a lower count rate capability. This is an advantage for low count-rate applications where the slower speed enables easier multiplexing in the read-out, thus potential higher multiplexing factors. In order to recover the higher count rate capabilities, a potential path exits using thicker silicon nitride membranes to increase the thermal conductance to the heat bath

    Design of Magnetic Shielding and Field Coils for a TES X-Ray Microcalorimeter Test Platform

    Get PDF
    The performance of Transition-Edge Sensors (TES) and their SQUID multiplexed read-outs are very sensitive to the ambient magnetic field from Earth and fluctuations that can arise due to fluctuating magnetic fields outside of the focal plane assembly from the Adiabatic Demagnetization Refrigerator (ADR).Thus, the experimental platform we are building to test the FPA of the X-ray Integral Field Unit (X-IFU) of the Athena mission needs to include a series of shields and a coil in order to meet the following requirement of magnetic field density and uniformity

    Fabrication of a Hybrid Transition Edge Sensor Array for Lynx

    Get PDF
    Lynx is a proposed NASA X-Ray telescope flight mission aimed at achieving state-of-the-art angular and energy resolution with a 100 kilopixel array to probe the hot energetic young universe in unprecedented detail. To achieve these goals, our team plans on leveraging our current work in development of the focal plane for the Athena X-Ray Integral Field Unit (X-IFU) while advancing the state-of-the-art in transition edge sensor (TES) X-ray detector technology. The TES is an optimal technology for achieving both high energy and fine angular resolution at the same time because pixel features can be made extremely small and the absorber which dominates the heat capacity can be tuned to meet resolution requirements. Specifically, the proposed mission concept calls for a hybrid detector of three different arrays fabricated in the same planar process in one focal plane and optimized for different science goals. The main arrays consist of 5x5 hydras, 25 pixels of 4 micron thick Au absorbers each with a different thermal link to one common TES. The outer array has absorbers on a 50-micron pitch for most of the 5 arc-minute field-of-view, and the inner array has 25-micron absorbers for the central 1 arc-minute region. A high resolution array consisting of single pixel 1 micron thick Au absorbers on 50-micron pitch will lie off to the side. Reading out an array of this magnitude will likely require improvements in indium bump bonding to superconducting flexible wiring. Fabrication of absorbers of two different sizes requires electroplating through a photoresist mold by careful tuning of the current density to achieve uniform flat absorbers on a fine pitch scale, followed by ion milling to yield narrow streets separating the pixels while preserving high quantum efficiency. We report on progress made at fabricating the hybrid array with different absorber sizes and thicknesses. Further, we also report on ongoing work to adequately heat sink the pixels with backside wire bonding and copper coating. We also report on work to improve detector pixel yield and top side indium bump bonding to flexible wiring

    Toward Large FOV High-Resolution X-Ray Imaging Spectrometer: Microwave Multiplexed Readout of 32 TES Microcalorimeters

    Get PDF
    We performed a small-scale demonstration at GSFC of high-resolution x-ray TES microcalorimeters read out using a microwave SQUID multiplexer. This work is part of our effort to develop detector and readout technologies for future space based x-ray instruments such as the microcalorimeter spectrometer envisaged for Lynx, a large mission concept under development for the Astro 2020 Decadal Survey. In this paper we describe our experiment, including details of a recently designed, microwave-optimized low-temperature setup that is thermally anchored to the 50 mK stage of our laboratory ADR. Using a ROACH2 FPGA at room temperature, we simultaneously read out 32 pixels of a GSFC-built detector array via a NIST-built multiplexer chip with Nb coplanar waveguide resonators coupled to RF SQUIDs. The resonators are spaced 6 MHz apart (at approx. 5.9 GHz) and have quality factors of approximately 15,000. Using flux-ramp modulation frequencies of 160 kHz we have achieved spectral resolutions of 3 eV FWHM on each pixel at 6 keV. We will present the measured system-level noise and maximum slew rates, and briefly describe the implications for future detector and readout design

    Fabrication of Transition Edge Sensor Microcalorimeters for X-Ray Focal Planes

    Get PDF
    Requirements for focal planes for x-ray astrophysics vary widely depending on the needs of the science application such as photon count rate, energy band, resolving power, and angular resolution. Transition edge sensor x-ray calorimeters can encounter limitations when optimized for these specific applications. Balancing specifications leads to choices in, for example, pixel size, thermal sinking arrangement, and absorber thickness and material. For the broadest specifications, instruments can benefit from multiple pixel types in the same array or focal plane. Here we describe a variety of focal plane architectures that anticipate science requirements of x-ray instruments for heliophysics and astrophysics. We describe the fabrication procedures that enable each array and explore limitations for the specifications of such arrays, including arrays with multiple pixel types on the same array

    Fabrication and Performance of Large Format Transition Edge Sensor Microcalorimeter Arrays

    Get PDF
    We have produced a variety of superconducting transition edge sensor array designs for microcalorimetric detection of x-rays. Designs include kilopixel scale arrays of relatively small sensors (~75 micron pitch) atop a thick metal heatsinking layer as well as arrays of membrane-isolated devices on 250 micron pitch and smaller arrays of devices up to 600 micron pitch. We discuss the fabrication techniques used for each type of array focusing on unique aspects where processes vary to achieve the particular designs and required device parameters. For example, we evaluate various material combinations in the production of the thick metal heatsinking, including superconducting and normal metal adhesion layers. We also evaluate the impact of added heatsinking on the membrane isolated devices as it relates to basic device parameters. Arrays can be characterized with a time division SQUID multiplexer such that greater than 10 devices from an array can be measured in the same cooldown. Device parameters can be measured simultaneously so that environmental events such as thermal drifts or changes in magnetic fields can be controlled. For some designs, we will evaluate the uniformity of parameters impacting the intrinsic performance of the microcalorimeters under bias in these arrays and assess the level of thermal crosstalk

    Detecting Protostellar Jets with the Goddard Fabry-Perot Coronagraph, and Modification for Adaptive Optics

    No full text
    The Goddard Fabry-Perot has been used at the Apache Point Observatory 3.5-m telescope to diagnose jets from young Herbig Ae (HD163296) and T Tauri stars (DL Tau and CW Tau), detected by the Space Telescope Imaging Spectrograph coronagraph on the Hubble Space Telescope. The additional spectral discrimination of the Fabry-Perot allows these faint jets to be detected from the ground, to obtain velocities and densities, and to find further extensions. In order to plan what measurements require space coronagraphs, we need to explore the extent to which coronagraphic detections can be made from the ground, including using adaptive optics. Modifications to the Fabry-Perot tunable narrow band coronagraph for possible use with the AEOS 3.65-m telescope will be described
    corecore