282 research outputs found

    Zu Heinrich Bullingers St.-Niklaus-SprĂŒchen

    Get PDF

    Zu Zwinglis PsalmenĂŒbersetzung

    Get PDF

    DFS Dive-control Brakes for Gliders and Airplanes ; And, Analytical Study of the Drag of the DFS Dive-control Brake

    Get PDF
    These two reports are surveys on the progress and present state of development of dive-control flaps for gliders and airplanes. The second article describes how on the basis of wind tunnel and free-flight tests, the drag increase on brake flaps of the type DFS, can be predicted. Pressure records confirm a two-dimensional load distribution along the brake-flap surface Aerodynamically, the location of the brake flaps along the span is of importance for reasons of avoidance of vibration and oscillation phenomena on control and tail surfaces; statically, because of the magnitude of the frontal drag in diving with respect to the bending moments, which may become decisive for the dimensions of the wing attachment and for the wing covering

    Studies on processing, particle formation, and immunogenicity of the HIV-1 gag gene product: a possible component of a HIV vaccine

    Get PDF
    Antigens in a particulate conformation were shown to be highly immunogenic in mammals. For this reason, the particle forming capacity of derivatives of the HIV-1 group specific core antigen p55 gag was assayed and compared dependent on various expression systems: recombinant bacteria, vaccinia- and baculoviruses were established encoding the entire core protein p55 either in its authentic sequence or lacking the myristylation consensus signal. Moreover, p55 gag was expressed in combination with the protease (p55-PR) or with the entire polymerase (p55-pol), respectively. Budding of 100-160 nm p55 core particles, resembling immature HIV-virions, was observed in the eucaryotic expression systems only. In comparison to the vaccinia virus driven expression of p55 in mammalian cells, considerably higher yields of particulate core antigen were obtained by infection of Spodoptera frugiperda (Sf9) insect cells with the recombinant Autographa californica nuclear polyhedrosis (AcMNPV) baculovirus. Mutation of the NH2-terminal myristylation signal sequence prevented budding of the immature core particles. Expression of the HIV p55-PR gene construct by recombinant baculovirus resulted in complete processing of the p55 gag precursor molecule in this system. The introduction of an artificial frameshift near the natural frameshift site resulted in constitutive expression of the viral protease and complete processing of p55, both in Escherichia coli and in vaccinia virus infected cells. Interestingly, significant processing of p55 resembling that of HIV infected H9 cells could also be achieved in the vaccinia system by fusing the entire pol gene to the gag gene. Moreover, processing was not found to be dependent on amino-terminal myristylation of the gag procursor molecule, which is in contrast to observations with type C and type D retrovirus. However, complete processing of p55 into p24, p17, p9 and p6 abolished particle formation. Purified immature HIV-virus like particles were highly immunogenic in rabbits, leading to a strong humoral immune response after immunization. Empty immature p55 gag particles represent a noninfectious and attractive candidate for a basic vaccine component

    Percutaneous iliosacral screw fixation in S1 and S2 for posterior pelvic ring injuries: technique and perioperative complications

    Get PDF
    Objective: Percutaneous iliosacral screw placement allows for minimally invasive fixation of posterior pelvic ring instabilities. The objective of this study was to describe the technique for screws in S1 and S2 using conventional C-arm and to evaluate perioperative complications. Methods: Thirty-eight consecutive patients after percutaneous pelvic ring fixation with cannulated screws in S1 and S2 using conventional C-arm fluoroscopy were analysed. Accuracy of screw placement, nerval lesions, need for second surgery, operation time, and time to full weight bearing were assessed postoperatively and during regular follow-up examinations. Results: Twenty-one patients underwent unilateral screw fixation and 17 patients underwent bilateral screw fixation. In total, 83 screws were placed. Mean age of the patients was 52±19years. Mean operation time was 16±7min/screw. Mean follow-up was 5±3months. Time to full weight bearing in 28 patients was 9±4weeks. Eight patients were still not able to support full weight bearing, partially due to concomitant injuries. Patients without concomitant injuries that affected walking were able to bear full weight after 8±4weeks (n=17). Two patients had persistent postoperative hypaesthesia. No motor weakness was apparent and no postoperative bleeding was observed. Secondary surgery due to screw malpositioning or loosening had to be performed in four patients. The presence of a screw in S2 was not indicated for perioperative complications. Conclusions: Percutaneous iliosacral screw fixation is a rapid and definitive treatment for posterior pelvic ring injuries with a low risk of secondary bleeding during posterior pelvic stabilization. The technique using standard C-arm fluoroscopy was also found to be safe for screws placed in S

    The calcar screw in angular stable plate fixation of proximal humeral fractures - a case study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>With new minimally-invasive approaches for angular stable plate fixation of proximal humeral fractures, the need for the placement of oblique inferomedial screws ('calcar screw') has increasingly been discussed. The purpose of this study was to investigate the influence of calcar screws on secondary loss of reduction and on the occurrence of complications.</p> <p>Methods</p> <p>Patients with a proximal humeral fracture who underwent angular stable plate fixation between 01/2007 and 07/2009 were included. On AP views of the shoulder, the difference in height between humeral head and the proximal end of the plate were determined postoperatively and at follow-up. Additionally, the occurrence of complications was documented. Patients with calcar screws were assigned to group C+, patients without to group C-.</p> <p>Results</p> <p>Follow-up was possible in 60 patients (C+ 6.7 ± 5.6 M/C- 5.0 ± 2.8 M). Humeral head necrosis occurred in 6 (C+, 15.4%) and 3 (C-, 14.3%) cases. Cut-out of the proximal screws was observed in 3 (C+, 7.7%) and 1 (C-, 4.8%) cases. In each group, 1 patient showed delayed union. Implant failure or lesions of the axillary nerve were not observed. In 44 patients, true AP and Neer views were available to measure the head-plate distance. There was a significant loss of reduction in group C- (2.56 ± 2.65 mm) compared to C+ (0.77 ± 1.44 mm; p = 0.01).</p> <p>Conclusions</p> <p>The placement of calcar screws in the angular stable plate fixation of proximal humeral fractures is associated with less secondary loss of reduction by providing inferomedial support. An increased risk for complications could not be shown.</p

    Use of Imatinib in the Prevention of Heterotopic Ossification

    Get PDF
    Background: Heterotopic ossification (HO) is a common complication following orthopedic and trauma surgery, which may have substantial negative effects on the postoperative outcome. Angiogenesis appears to play a critical role in heterotopic ossification. One of the involved signaling molecules is platelet-derived growth factor (PDGF) which may be inhibited by imatinib. Questions/Purposes: Our goal was to prevent HO by pharmacologically interfering with the molecular signaling pathways involved in the developmental process. We hypothesized that by administering a proven inhibitor of PDGF expression, heterotopic bone formation may be prevented. Methods: The effect of imatinib on HO formation was studied in a murine model which reliably produces islets of HO within the soft tissue following Achilles tenotomy. The control group underwent Achilles tenotomy only. The imatinib group received imatinib mesylate. After trial completion, the limbs were harvested and scanned by micro-CT. Heterotopic bone volume was then identified and quantified. Results: The mean volume of heterotopic bone formed in the control group was 0.976mm3 compared to 0.221mm3 in the imatinib group. The volume of HO in the treatment group was reduced by 85% compared to the control group. Conclusions: The administration of imatinib was associated with a significantly reduced volume of HO. This may be due to the inhibitory effect of imatinib on the PDGF signaling pathway during development of HO. Clinical Relevance: The successful reduction of HO formation following imatinib administration has led to further insight concerning the pathogenesis of HO which in the future may lead to new clinical approaches towards the prevention of H

    Treatment of femoral neck fractures in elderly patients over 60 years of age - which is the ideal modality of primary joint replacement?

    Get PDF
    BACKGROUND: Femoral neck fractures in the elderly are frequent, represent a great health care problem, and have a significant impact on health insurance costs. Reconstruction options using hip arthroplasty include unipolar or bipolar hemiarthroplasty (HA), and total hip arthroplasty (THA). The purpose of this review is to discuss the indications, limitations, and pitfalls of each of these techniques. METHODS: The Pubmed database was searched for all articles on femoral neck fracture and for the reconstruction options presented in this review using the search terms "femoral neck fracture", "unipolar hemiarthroplasty", "bipolar hemiarthroplasty", and "total hip arthroplasty". In addition, cross-referencing was used to cover articles eventually undetected by the respective search strategies. The resulting articles were then reviewed with regard to the different techniques, outcome and complications of the distinct reconstruction options. RESULTS: THA yields the best functional results in patients with displaced femoral neck fractures with complication rates comparable to HA. THA is beneficially implanted using an anterior approach exploiting the internervous plane between the tensor fasciae latae and the sartorius muscles allowing for immediate full weight-bearing. Based on our findings, bipolar hemiarthroplasty, similar to unipolar hemiarthroplasty, cannot restorate neither anatomical nor biomechanical features of the hip joint. Therefore, it can only be recommended as a second line of defense-procedure for patients with low functional demands and limited live expectancy. CONCLUSIONS: THA is the treatment of choice for femoral neck fractures in patients older than 60 years. HA should only be implanted in patients with limited life expectanc

    Augmented reality-based surgical navigation of pelvic screw placement: an ex-vivo experimental feasibility study

    Get PDF
    BACKGROUND Minimally invasive surgical treatment of pelvic trauma requires a significant level of surgical training and technical expertise. Novel imaging and navigation technologies have always driven surgical technique, and with head-mounted displays being commercially available nowadays, the assessment of such Augmented Reality (AR) devices in a specific surgical setting is appropriate. METHODS In this ex-vivo feasibility study, an AR-based surgical navigation system was assessed in a specific clinical scenario with standard pelvic and acetabular screw pathways. The system has the following components: an optical-see-through Head Mounted Display, a specifically designed modular AR software, and surgical tool tracking using pose estimation with synthetic square markers. RESULTS The success rate for entry point navigation was 93.8%, the overall translational deviation of drill pathways was 3.99 ± 1.77 mm, and the overall rotational deviation of drill pathways was 4.3 ± 1.8°. There was no relevant theoretic screw perforation, as shown by 88.7% Grade 0-1 and 100% Grade 0-2 rating in our pelvic screw perforation score. Regarding screw length, 103 ± 8% of the planned pathway length could be realized successfully. CONCLUSION The novel innovative system assessed in this experimental study provided proof-of-concept for the feasibility of percutaneous screw placement in the pelvis and, thus, could easily be adapted to a specific clinical scenario. The system showed comparable performance with other computer-aided solutions while providing specific advantages such as true 3D vision without intraoperative radiation; however, it needs further improvement and must still undergo regulatory body approval. Future endeavors include intraoperative registration and optimized tool tracking
    • 

    corecore