564 research outputs found

    Microwave assisted heterogeneous catalysis: effects of varying oxygen concentrations on the oxidative coupling of methane

    No full text
    The oxidative coupling of methane was investigated over alumina supported La2O3/CeO2 catalysts under microwave dielectric heating conditions at different oxygen concentrations. It was observed that, at a given temperature using microwave heating, selectivities for both ethane and ethylene were notably higher when oxygen was absent than that in oxygen/methane mixtures. The differences were attributed to the localised heating of microwave radiation resulting in temperature inhomogeneity in the catalyst bed. A simplified model was used to estimate the temperature inhomogeneity; the temperature at the centre of the catalyst bed was 85 °C greater than that at the periphery when the catalyst was heated by microwaves in a gas mixture with an oxygen concentration of 12.5% (v/v), and the temperature difference was estimated to be 168 °C in the absence of oxygen

    Co-seismic ground deformation of Yushu Earthquake detected with D-InSAR technique

    Get PDF
    An earthquake of magnitude 7.1 suddenly occurred in Yushu county of Qinghai province on April 14, 2010. This paper presents the studies of using the data of Advanced Land Observing Satellite-Phased Array type L-band Synthetic Aperture Radar (ALOS-PALSAR) before and after the earthquake to examine and calculate the co-seismic ground deformation. The differential SAR interferometry (D-InSAR) technique is used. The results show that the earthquake caused the ground deformation over a large area. The extension of the ground deformation followed the south-east to east direction and along the Yushu-Ganzi fault zone. The largest deformation was found about 350 mm at 33.7°N 96.81°E. It is along the line of sight (LOS) of SAR and can be detected with D-InSAR technique. The detected ground deformation was mainly uplifting. The detected ground deformation has an important value for evaluating the extent of ground damage and seismicity in Yushu after earthquake, inferring the nature of the quake faulting, and studying characteristics of seismic deformation. 2010-04-14青海玉树发生7.1级地震后, 作者利用震前和震后获取的日本ALOS卫星PALSAR遥感数据, 开展了差分干涉雷达(D-InSAR)地震同震形变测量与分析。结果表明: 玉树地震引起较大范围地表变形, 地震变形沿玉树—甘孜断裂带向南东东方向扩展, 在N33.7°, E96.81°附近达到最大形变量, D-InSAR监测到雷达视向上的最大形变量为35cm。地表形变特征对于评价玉树地震破坏程度、推断断层性质、研究地震形变和地震孕育特征具有重要的参考价值

    Electrospun ZnO Nanowires as Gas Sensors for Ethanol Detection

    Get PDF
    ZnO nanowires were produced using an electrospinning method and used in gas sensors for the detection of ethanol at 220 °C. This electrospinning technique allows the direct placement of ZnO nanowires during their synthesis to bridge the sensor electrodes. An excellent sensitivity of nearly 90% was obtained at a low ethanol concentration of 10 ppm, and the rest obtained at higher ethanol concentrations, up to 600 ppm, all equal to or greater than 90%

    Observation of a ppb mass threshoud enhancement in \psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) decay

    Full text link
    The decay channel ψπ+πJ/ψ(J/ψγppˉ)\psi^\prime\to\pi^+\pi^-J/\psi(J/\psi\to\gamma p\bar{p}) is studied using a sample of 1.06×1081.06\times 10^8 ψ\psi^\prime events collected by the BESIII experiment at BEPCII. A strong enhancement at threshold is observed in the ppˉp\bar{p} invariant mass spectrum. The enhancement can be fit with an SS-wave Breit-Wigner resonance function with a resulting peak mass of M=186113+6(stat)26+7(syst)MeV/c2M=1861^{+6}_{-13} {\rm (stat)}^{+7}_{-26} {\rm (syst)} {\rm MeV/}c^2 and a narrow width that is Γ<38MeV/c2\Gamma<38 {\rm MeV/}c^2 at the 90% confidence level. These results are consistent with published BESII results. These mass and width values do not match with those of any known meson resonance.Comment: 5 pages, 3 figures, submitted to Chinese Physics

    A new integrated and homogenized global monthly land surface air temperature dataset for the period since 1900

    Get PDF
    A new dataset of integrated and homogenized monthly surface air temperature over global land for the period since 1900 [China Meteorological Administration global Land Surface Air Temperature (CMA-LSAT)] is developed. In total, 14 sources have been collected and integrated into the newly developed dataset, including three global (CRUTEM4, GHCN, and BEST), three regional and eight national sources. Duplicate stations are identified, and those with the higher priority are chosen or spliced. Then, a consistency test and a climate outlier test are conducted to ensure that each station series is quality controlled. Next, two steps are adopted to assure the homogeneity of the station series: (1) homogenized station series in existing national datasets (by National Meteorological Services) are directly integrated into the dataset without any changes (50% of all stations), and (2) the inhomogeneities are detected and adjusted for in the remaining data series using a penalized maximal t test (50% of all stations). Based on the dataset, we re-assess the temperature changes in global and regional areas compared with GHCN-V3 and CRUTEM4, as well as the temperature changes during the three periods of 1900–2014, 1979–2014 and 1998–2014. The best estimates of warming trends and there 95% confidence ranges for 1900–2014 are approximately 0.102 ± 0.006 °C/decade for the whole year, and 0.104 ± 0.009, 0.112 ± 0.007, 0.090 ± 0.006, and 0.092 ± 0.007 °C/decade for the DJF (December, January, February), MAM, JJA, and SON seasons, respectively. MAM saw the most significant warming trend in both 1900–2014 and 1979–2014. For an even shorter and more recent period (1998–2014), MAM, JJA and SON show similar warming trends, while DJF shows opposite trends. The results show that the ability of CMA-LAST for describing the global temperature changes is similar with other existing products, while there are some differences when describing regional temperature changes

    The generalized Hamiltonian model for the shafting transient analysis of the hydro turbine generating sets.

    Get PDF
    yesTraditional rotor dynamics mainly focuses on the steady- state behavior of the rotor and shafting. However, for systems such as hydro turbine generating sets (HTGS) where the control and regulation is frequently applied, the shafting safety and stabilization in transient state is then a key factor. The shafting transient state inevitably involves multiparameter domain, multifield coupling, and coupling dynamics. In this paper, the relative value form of the Lagrange function and its equations have been established by defining the base value system of the shafting. Takingthe rotation angle and the angular speed of the shafting as a link, the shafting lateral vibration and generator equations are integrated into the framework of generalized Hamiltonian system. The generalized Hamiltonian control model is thus established. To make the model more general, additional forces of the shafting are taken as the input excitation in proposed model. The control system of the HTGS can be easily connected with the shafting model to form the whole simulation system of the HTGS. It is expected that this study will build a foundation for the coupling dynamics theory using the generalized Hamiltonian theory to investigate coupling dynamic mechanism among the shafting vibration, transient of hydro turbine generating sets, and additional forces of the shafting.National Natural Science Foundation of China under Grant Nos. 51179079 and 5083900

    Specification and guideline for technical aspects and scanning parameter settings of neonatal lung ultrasound examination

    Get PDF
    Lung ultrasound (LUS) is now widely used in the diagnosis and monitor of neonatal lung diseases.Nevertheless, in the published literatures,the LUS images may display a significant variation in technical execution,while scanning parameters may influence diagnostic accuracy.The inter- and intra-observer reliabilities of ultrasound exam have been extensively studied in general and in LUS.As expected,the reliability declines in the hands of novices when they perform the point-of-care ultrasound (POC US).Consequently,having appropriate guidelines regarding to technical aspects of neonatal LUS exam is very important especially because diagnosis is mainly based on interpretation of artifacts produced by the pleural line and the lungs.The present work aimed to create an instrument operation specification and parameter setting guidelines for neonatal LUS.Technical aspects and scanning parameter settings that allow for standardization in obtaining LUS images include (1)select a high-end equipment with high-frequency linear array transducer (12-14 MHz).(2)Choose preset suitable for lung examination or small organs.(3)Keep the probe perpendicular to the ribs or parallel to the intercostal space.(4)Set the scanning depth at 4-5 cm.(5)Set 1-2 focal zones and adjust them close to the pleural line.(6)Use fundamental frequency with speckle reduction 2-3 or similar techniques.(7)Turn off spatial compounding imaging.(8)Adjust the time-gain compensation to get uniform image from the near-to far-field

    A Comparative Approach Linking Molecular Dynamics of Altered Peptide Ligands and MHC with In Vivo Immune Responses

    Get PDF
    The recognition of peptide in the context of MHC by T lymphocytes is a critical step in the initiation of an adaptive immune response. However, the molecular nature of the interaction between peptide and MHC and how it influences T cell responsiveness is not fully understood.We analyzed the immunological consequences of the interaction of MHC class II (I-Au) restricted 11-mer peptides of myelin basic protein with amino acid substitutions at position 4. These mutant peptides differ in MHC binding affinity, CD4+ T cell priming, and alter the severity of peptide-induced experimental allergic encephalomyelitis. Using molecular dynamics, a computational method of quantifying intrinsic movements of proteins at high resolution, we investigated conformational changes in MHC upon peptide binding. We found that irrespective of peptide binding affinity, MHC deformation appears to influence costimulation, which then leads to effective T cell priming and disease induction. Although this study compares in vivo and molecular dynamics results for three altered peptide ligands, further investigation with similar complexes is essential to determine whether spatial rearrangement of peptide-MHC and costimulatory complexes is an additional level of T cell regulation
    corecore