576 research outputs found
Tin perovskite/fullerene planar layer photovoltaics : improving the efficiency and stability of lead-free devices
We report the first demonstration of orthorhombic CsSnI3 films prepared from solution at room temperature that have defect densities low enough for use as the light harvesting semiconductor in photovoltaic devices even without using excess Sn in the preparative method, and demonstrate their utility in a model p–i–n photovoltaic device based on a CuI | CsSnI3 | fullerene planar layer architecture. We also report an effective strategy for simultaneously improving both the efficiency and stability of these devices towards air exposure based on the use of excess of SnI2 during CsSnI3 synthesis from CsI and SnI2. A combination of photoelectron spectroscopy, contact potential measurements and device based studies are used to elucidate the basis for this improvement and role of the excess SnI2. The open-circuit voltage in these lead-free photovoltaic devices is shown to be strongly dependent on the degree of alignment between the perovskite conduction band edge and the lowest occupied molecular orbital (LUMO) in the fullerene electron transport layer. Furthermore, the energetics at the perovskite–fullerene interface are shown to be a function both of the LUMO energy of the fullerene and the nature of the interaction at the heterojunction which can give rise to a large abrupt vacuum level shift across the interface. A champion open-circuit voltage of ∼0.55 V is achieved using indene-C60 bis-adduct as the electron extraction layer, which is twice that previously reported for a CsSnI3 based PPV
Enhanced stability and efficiency in hole-transport-layer-free CsSnI3 perovskite photovoltaics
Photovoltaics based on tin halide perovskites have not yet benefitted from the same intensive research effort that has propelled lead perovskite photovoltaics to >20% power conversion efficiency, due to the susceptibility of tin perovskites to oxidation, the low energy of defect formation and the difficultly in forming pin-hole free films. Here we report CsSnI3 perovskite photovoltaic devices without a hole-selective interfacial layer that exhibit a stability 10 times greater than devices with the same architecture using methylammonium lead iodide perovskite, and the highest efficiency to date for a CsSnI3 photovoltaic: 3.56%. The latter results in large part from a high device fill-factor, achieved using a strategy that removes the need for an electron blocking layer or an additional processing step to minimise the pinhole density in the perovskite film, based on co-depositing the perovskite precursors with SnCl2. These two findings raise the prospect that this class of lead-free perovskite photovoltaic may yet prove viable for applications
Long XMM observation of the Narrow-Line Seyfert 1 galaxy IRAS13224-3809: rapid variability, high spin and a soft lag
Results are presented from a 500ks long XMM-Newton observation of the
Narrow-Line Seyfert 1 galaxy IRAS13224-3809. The source is rapidly variable on
timescales down to a few 100s. The spectrum shows strong broad Fe-K and L
emission features which are interpreted as arising from reflection from the
inner parts of an accretion disc around a rapidly spinning black hole. Assuming
a power-law emissivity for the reflected flux and that the innermost radius
corresponds to the innermost stable circular orbit, the black hole spin is
measured to be 0.988 with a statistical precision better than one per cent.
Systematic uncertainties are discussed. A soft X-ray lag of 100s confirms this
scenario. The bulk of the power-law continuum source is located at a radius of
2-3 gravitational radii.Comment: 7 pages, 14 figures, submitted to MNRA
Ross, Macdonald, and a Theory for the Dynamics and Control of Mosquito-Transmitted Pathogens
Ronald Ross and George Macdonald are credited with developing a mathematical model of mosquito-borne pathogen transmission. A systematic historical review suggests that several mathematicians and scientists contributed to development of the Ross-Macdonald model over a period of 70 years. Ross developed two different mathematical models, Macdonald a third, and various “Ross-Macdonald” mathematical models exist. Ross-Macdonald models are best defined by a consensus set of assumptions. The mathematical model is just one part of a theory for the dynamics and control of mosquito-transmitted pathogens that also includes epidemiological and entomological concepts and metrics for measuring transmission. All the basic elements of the theory had fallen into place by the end of the Global Malaria Eradication Programme (GMEP, 1955–1969) with the concept of vectorial capacity, methods for measuring key components of transmission by mosquitoes, and a quantitative theory of vector control. The Ross-Macdonald theory has since played a central role in development of research on mosquito-borne pathogen transmission and the development of strategies for mosquito-borne disease prevention
Measuring Black Hole Spin using X-ray Reflection Spectroscopy
I review the current status of X-ray reflection (a.k.a. broad iron line)
based black hole spin measurements. This is a powerful technique that allows us
to measure robust black hole spins across the mass range, from the stellar-mass
black holes in X-ray binaries to the supermassive black holes in active
galactic nuclei. After describing the basic assumptions of this approach, I lay
out the detailed methodology focusing on "best practices" that have been found
necessary to obtain robust results. Reflecting my own biases, this review is
slanted towards a discussion of supermassive black hole (SMBH) spin in active
galactic nuclei (AGN). Pulling together all of the available XMM-Newton and
Suzaku results from the literature that satisfy objective quality control
criteria, it is clear that a large fraction of SMBHs are rapidly-spinning,
although there are tentative hints of a more slowly spinning population at high
(M>5*10^7Msun) and low (M<2*10^6Msun) mass. I also engage in a brief review of
the spins of stellar-mass black holes in X-ray binaries. In general,
reflection-based and continuum-fitting based spin measures are in agreement,
although there remain two objects (GROJ1655-40 and 4U1543-475) for which that
is not true. I end this review by discussing the exciting frontier of
relativistic reverberation, particularly the discovery of broad iron line
reverberation in XMM-Newton data for the Seyfert galaxies NGC4151, NGC7314 and
MCG-5-23-16. As well as confirming the basic paradigm of relativistic disk
reflection, this detection of reverberation demonstrates that future large-area
X-ray observatories such as LOFT will make tremendous progress in studies of
strong gravity using relativistic reverberation in AGN.Comment: 19 pages. To appear in proceedings of the ISSI-Bern workshop on "The
Physics of Accretion onto Black Holes" (8-12 Oct 2012). Revised version adds
a missing source to Table 1 and Fig.6 (IRAS13224-3809) and corrects the
referencing of the discovery of soft lags in 1H0707-495 (which were in fact
first reported in Fabian et al. 2009
An Anti-Human ICAM-1 Antibody Inhibits Rhinovirus-Induced Exacerbations of Lung Inflammation
Human rhinoviruses (HRV) cause the majority of common colds and acute exacerbations of asthma and chronic obstructive pulmonary disease (COPD). Effective therapies are urgently needed, but no licensed treatments or vaccines currently exist. Of the 100 identified serotypes, ∼90% bind domain 1 of human intercellular adhesion molecule-1 (ICAM-1) as their cellular receptor, making this an attractive target for development of therapies; however, ICAM-1 domain 1 is also required for host defence and regulation of cell trafficking, principally via its major ligand LFA-1. Using a mouse anti-human ICAM-1 antibody (14C11) that specifically binds domain 1 of human ICAM-1, we show that 14C11 administered topically or systemically prevented entry of two major groups of rhinoviruses, HRV16 and HRV14, and reduced cellular inflammation, pro-inflammatory cytokine induction and virus load in vivo. 14C11 also reduced cellular inflammation and Th2 cytokine/chemokine production in a model of major group HRV-induced asthma exacerbation. Interestingly, 14C11 did not prevent cell adhesion via human ICAM-1/LFA-1 interactions in vitro, suggesting the epitope targeted by 14C11 was specific for viral entry. Thus a human ICAM-1 domain-1-specific antibody can prevent major group HRV entry and induction of airway inflammation in vivo
NuSTAR and XMM-Newton observations of NGC 1365: Extreme absorption variability and a constant inner accretion disk
We present a spectral analysis of four coordinated NuSTAR+XMM-Newton
observations of the Seyfert galaxy NGC 1365. These exhibit an extreme level of
spectral variability, which is primarily due to variable line-of-sight
absorption, revealing relatively unobscured states in this source for the first
time. Despite the diverse range of absorption states, each of the observations
displays the same characteristic signatures of relativistic reflection from the
inner accretion disk. Through time-resolved spectroscopy we find that the
strength of the relativistic iron line and the Compton reflection hump relative
to the intrinsic continuum are well correlated, as expected if they are two
aspects of the same broadband reflection spectrum. We apply self-consistent
disk reflection models to these time-resolved spectra in order to constrain the
inner disk parameters, allowing for variable, partially covering absorption to
account for the vastly different absorption states observed. Each of the four
observations is treated independently to test the consistency of the results
obtained for the black hole spin and the disk inclination, which should not
vary on observable timescales. We find both the spin and the inclination
determined from the reflection spectrum to be consistent, confirming NGC 1365
hosts a rapidly rotating black hole; in all cases the dimensionless spin
parameter is constrained to be a* > 0.97 (at 90% statistical confidence or
better)
False positive circumsporozoite protein ELISA: a challenge for the estimation of the entomological inoculation rate of malaria and for vector incrimination
<p>Abstract</p> <p>Background</p> <p>The entomological inoculation rate (EIR) is an important indicator in estimating malaria transmission and the impact of vector control. To assess the EIR, the enzyme-linked immunosorbent assay (ELISA) to detect the circumsporozoite protein (CSP) is increasingly used. However, several studies have reported false positive results in this ELISA. The false positive results could lead to an overestimation of the EIR. The aim of present study was to estimate the level of false positivity among different anopheline species in Cambodia and Vietnam and to check for the presence of other parasites that might interact with the anti-CSP monoclonal antibodies.</p> <p>Methods</p> <p>Mosquitoes collected in Cambodia and Vietnam were identified and tested for the presence of sporozoites in head and thorax by using CSP-ELISA. ELISA positive samples were confirmed by a <it>Plasmodium </it>specific PCR. False positive mosquitoes were checked by PCR for the presence of parasites belonging to the Haemosporidia, Trypanosomatidae, Piroplasmida, and Haemogregarines. The heat-stability and the presence of the cross-reacting antigen in the abdomen of the mosquitoes were also checked.</p> <p>Results</p> <p>Specimens (N = 16,160) of seven anopheline species were tested by CSP-ELISA for <it>Plasmodium falciparum </it>and <it>Plasmodium vivax </it>(Pv210 and Pv247). Two new vector species were identified for the region: <it>Anopheles pampanai </it>(<it>P. vivax</it>) and <it>Anopheles barbirostris </it>(<it>Plasmodium malariae</it>). In 88% (155/176) of the mosquitoes found positive with the <it>P. falciparum </it>CSP-ELISA, the presence of <it>Plasmodium </it>sporozoites could not be confirmed by PCR. This percentage was much lower (28% or 5/18) for <it>P. vivax </it>CSP-ELISAs. False positive CSP-ELISA results were associated with zoophilic mosquito species. None of the targeted parasites could be detected in these CSP-ELISA false positive mosquitoes. The ELISA reacting antigen of <it>P. falciparum </it>was heat-stable in CSP-ELISA true positive specimens, but not in the false positives. The heat-unstable cross-reacting antigen is mainly present in head and thorax and almost absent in the abdomens (4 out of 147) of the false positive specimens.</p> <p>Conclusion</p> <p>The CSP-ELISA can considerably overestimate the EIR, particularly for <it>P. falciparum </it>and for zoophilic species. The heat-unstable cross-reacting antigen in false positives remains unknown. Therefore it is highly recommended to confirm all positive CSP-ELISA results, either by re-analysing the heated ELISA lysate (100°C, 10 min), or by performing <it>Plasmodium </it>specific PCR followed if possible by sequencing of the amplicons for <it>Plasmodium </it>species determination.</p
Optimal functional outcome measures for assessing treatment for Dupuytren's disease: A systematic review and recommendations for future practice
This article is available through the Brunel Open Access Publishing Fund. Copyright © 2013 Ball et al.; licensee BioMed Central Ltd.Background: Dupuytren's disease of the hand is a common condition affecting the palmar fascia, resulting in progressive flexion deformities of the digits and hence limitation of hand function. The optimal treatment remains unclear as outcomes studies have used a variety of measures for assessment. Methods: A literature search was performed for all publications describing surgical treatment, percutaneous needle aponeurotomy or collagenase injection for primary or recurrent Dupuytren’s disease where outcomes had been monitored using functional measures. Results: Ninety-one studies met the inclusion criteria. Twenty-two studies reported outcomes using patient reported outcome measures (PROMs) ranging from validated questionnaires to self-reported measures for return to work and self-rated disability. The Disability of Arm, Shoulder and Hand (DASH) score was the most utilised patient-reported function measure (n=11). Patient satisfaction was reported by eighteen studies but no single method was used consistently. Range of movement was the most frequent physical measure and was reported in all 91 studies. However, the methods of measurement and reporting varied, with seventeen different techniques being used. Other physical measures included grip and pinch strength and sensibility, again with variations in measurement protocols. The mean follow-up time ranged from 2 weeks to 17 years. Conclusions: There is little consistency in the reporting of outcomes for interventions in patients with Dupuytren’s disease, making it impossible to compare the efficacy of different treatment modalities. Although there are limitations to the existing generic patient reported outcomes measures, a combination of these together with a disease-specific questionnaire, and physical measures of active and passive individual joint Range of movement (ROM), grip and sensibility using standardised protocols should be used for future outcomes studies. As Dupuytren’s disease tends to recur following treatment as well as extend to involve other areas of the hand, follow-up times should be standardised and designed to capture both short and long term outcomes
- …