    Hypertensive patients' use of blood pressure monitors stationed in pharmacies and other locations: a cross-sectional mail survey

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Blood pressure (BP) monitors are commonly stationed in public places such as pharmacies, but it is uncertain how many people with hypertension currently use them. We sought to estimate the proportion of hypertensive patients who use these types of monitors and examine whether use varies by demographic or health characteristics.</p> <p>Methods</p> <p>We conducted a cross-sectional mail survey of hypertensive adults enrolled in a practice based research network of 24 primary care practices throughout the state of North Carolina. We analyzed results using descriptive statistics and examined bivariate associations using chi-square and independent associations using logistic regression.</p> <p>Results</p> <p>We received 530 questionnaires (76% response rate). Of 333 respondents (63%) who reported checking their BP in locations other than their doctor's office or home, 66% reported using a monitor stationed in a pharmacy. Younger patients more commonly reported using pharmacy monitors (48% among those < 45 years vs 35% of those over 65, p = 0.04). Blacks reported using them more commonly than whites (48% vs 39%, p = 0.03); and high school graduates more often than those with at least some college (50% vs 37%, p = 0.02). In multivariate analysis, younger age (aOR 1.49; 95% CI 1.00–2.21 for those age 45 to 65 years vs those > 65 years old) and high school education (aOR 1.74; 95% CI 1.13–2.58) were associated with use of pharmacy-stationed monitors, but Black race was not. Patients with diabetes, heart disease, or stroke were not more likely to use pharmacy-stationed monitors.</p> <p>Conclusion</p> <p>Hypertensive patients' use of BP monitors located in pharmacies is common. Younger patients, Blacks, and those with high school education were slightly more likely to report using them. Because use of these monitors is so common, efforts to ensure their accuracy are important.</p

    Interpreting and acting upon home blood pressure readings: A qualitative study

    Get PDF
    This article is made available through the Brunel Open Access Publishing Fund. Copyright @ 2013 Vasileiou et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Background: Recent guidelines recognize the importance of home blood pressure monitoring (HBPM) as an adjunct to clinical measurements. We explored how people who have purchased and use a home blood pressure (BP) monitor make sense of, and act upon, readings and how they communicate with their doctor about the practice of home monitoring. Methods: A qualitative study was designed and participants were purposively recruited from several areas in England, UK. Semi-structured in-depth interviews were conducted with 18 users of home BP monitors. The transcribed data were thematically analysed. Results: Interpretation of home BP readings is complex, and is often characterised by uncertainty. People seek to assess value normality using ‘rules of thumb’, and often aim to identify the potential causes of the readings. This is done by drawing on lay models of BP function and by contextualising the readings to personal circumstances. Based on the perceived causes of the problematic readings, actions are initiated, mostly relating to changes in daily routines. Contacting the doctor was more likely when the problematic readings persisted and could not be easily explained, or when participants did not succeed in regulating their BP through their other interventions. Most users had notified their doctor of the practice of home monitoring, but medical involvement varied, with some participants reporting disinterest or reservations by doctors. Conclusions: Involvement from doctors can help people overcome difficulties and resolve uncertainties around the interpretation of home readings, and ensure that the rules of thumb are appropriate. Home monitoring can be used to strengthen the patient-clinician relationship

    Does self-monitoring reduce blood pressure? Meta-analysis with meta-regression of randomized controlled trials

    Get PDF
    Introduction. Self-monitoring of blood pressure (BP) is an increasingly common part of hypertension management. The objectives of this systematic review were to evaluate the systolic and diastolic BP reduction, and achievement of target BP, associated with self-monitoring. Methods. MEDLINE, Embase, Cochrane database of systematic reviews, database of abstracts of clinical effectiveness, the health technology assessment database, the NHS economic evaluation database, and the TRIP database were searched for studies where the intervention included self-monitoring of BP and the outcome was change in office/ambulatory BP or proportion with controlled BP. Two reviewers independently extracted data. Meta-analysis using a random effects model was combined with meta-regression to investigate heterogeneity in effect sizes. Results. A total of 25 eligible randomized controlled trials (RCTs) (27 comparisons) were identified. Office systolic BP (20 RCTs, 21 comparisons, 5,898 patients) and diastolic BP (23 RCTs, 25 comparisons, 6,038 patients) were significantly reduced in those who self-monitored compared to usual care (weighted mean difference (WMD) systolic −3.82 mmHg (95% confidence interval −5.61 to −2.03), diastolic −1.45 mmHg (−1.95 to −0.94)). Self-monitoring increased the chance of meeting office BP targets (12 RCTs, 13 comparisons, 2,260 patients, relative risk = 1.09 (1.02 to 1.16)). There was significant heterogeneity between studies for all three comparisons, which could be partially accounted for by the use of additional co-interventions. Conclusion. Self-monitoring reduces blood pressure by a small but significant amount. Meta-regression could only account for part of the observed heterogeneity

    Non-invasive assessment of peripheral arterial disease: Automated ankle brachial index measurement and pulse volume analysis compared to duplex scan

    Get PDF
    Objectives: This cross-sectional study aimed to individually and cumulatively compare sensitivity and specificity of the (1) ankle brachial index and (2) pulse volume waveform analysis recorded by the same automated device, with the presence or absence of peripheral arterial disease being verified by ultrasound duplex scan. Methods: Patients (n=205) referred for lower limb arterial assessment underwent ankle brachial index measurement and pulse volume waveform recording using volume plethysmography, followed by ultrasound duplex scan. The presence of peripheral arterial disease was recorded if ankle brachial index 50% was evident with ultrasound duplex scan. Outcome measure was agreement between the measured ankle brachial index and interpretation of pulse volume waveform for peripheral arterial disease diagnosis, using ultrasound duplex scan as the reference standard. Results: Sensitivity of ankle brachial index was 79%, specificity 91% and overall accuracy 88%. Pulse volume waveform sensitivity was 97%, specificity 81% and overall accuracy 85%. The combined sensitivity of ankle brachial index and pulse volume waveform was 100%, specificity 76% and overall accuracy 85%. Conclusion: Combining these two diagnostic modalities within one device provided a highly accurate method of ruling out peripheral arterial disease, which could be utilised in primary care to safely reduce unnecessary secondary care referrals

    Does a colour-coded blood pressure diary improve blood pressure control for patients in general practice: The CoCo trial

    Get PDF
    BACKGROUND: Insufficient blood pressure control is a frequent problem despite the existence of effective treatment. Insufficient adherence to self-monitoring as well as to therapy is a common reason. Blood pressure self-measurement at home (Home Blood Pressure Measurement, HBPM) has positive effects on treatment adherence and is helpful in achieving the target blood pressure. Only a few studies have investigated whether adherence to HBPM can be improved through simple measures resulting also in better blood pressure control. OBJECTIVE: Improvement of self-monitoring and improved blood pressure control by using a new colour-coded blood pressure diary. OUTCOME: Primary outcome: Change in systolic and/or diastolic blood pressure 6 months after using the new colour-coded blood pressure diary.Secondary outcome: Adherence to blood pressure self-measurement (number of measurements/entries). METHODS/DESIGN: Randomised controlled study.Population: 138 adult patients in primary care with uncontrolled hypertension despite therapy. The control group uses a conventional blood pressure diary; the intervention group uses the new colour-coded blood pressure diary (green, yellow, red according a traffic light system). EXPECTED RESULTS/CONCLUSION: The visual separation and entries in three colour-coded areas reflecting risk (green: blood pressure in the target range 140/>90 mmHg, red: blood pressure in danger zone > 180 mmHg/>110 mmHg) lead to better self-monitoring compared with the conventional (non-colour-coded) blood pressure booklet. The colour-coded, visualised information supports improved perception (awareness and interpretation) of blood pressure and triggers correct behaviour, in the means of improved adherence to the recommended treatment as well as better communication between patients and doctors resulting in improved blood pressure control. TRIAL REGISTRATION: ClinicalTrials.gov ID NCT01013467

    Self-monitoring of blood pressure in hypertension: A systematic review and individual patient data meta-analysis.

    Get PDF
    BACKGROUND: Self-monitoring of blood pressure (BP) appears to reduce BP in hypertension but important questions remain regarding effective implementation and which groups may benefit most. This individual patient data (IPD) meta-analysis was performed to better understand the effectiveness of BP self-monitoring to lower BP and control hypertension. METHODS AND FINDINGS: Medline, Embase, and the Cochrane Library were searched for randomised trials comparing self-monitoring to no self-monitoring in hypertensive patients (June 2016). Two reviewers independently assessed articles for eligibility and the authors of eligible trials were approached requesting IPD. Of 2,846 articles in the initial search, 36 were eligible. IPD were provided from 25 trials, including 1 unpublished study. Data for the primary outcomes-change in mean clinic or ambulatory BP and proportion controlled below target at 12 months-were available from 15/19 possible studies (7,138/8,292 [86%] of randomised participants). Overall, self-monitoring was associated with reduced clinic systolic blood pressure (sBP) compared to usual care at 12 months (-3.2 mmHg, [95% CI -4.9, -1.6 mmHg]). However, this effect was strongly influenced by the intensity of co-intervention ranging from no effect with self-monitoring alone (-1.0 mmHg [-3.3, 1.2]), to a 6.1 mmHg (-9.0, -3.2) reduction when monitoring was combined with intensive support. Self-monitoring was most effective in those with fewer antihypertensive medications and higher baseline sBP up to 170 mmHg. No differences in efficacy were seen by sex or by most comorbidities. Ambulatory BP data at 12 months were available from 4 trials (1,478 patients), which assessed self-monitoring with little or no co-intervention. There was no association between self-monitoring and either lower clinic or ambulatory sBP in this group (clinic -0.2 mmHg [-2.2, 1.8]; ambulatory 1.1 mmHg [-0.3, 2.5]). Results for diastolic blood pressure (dBP) were similar. The main limitation of this work was that significant heterogeneity remained. This was at least in part due to different inclusion criteria, self-monitoring regimes, and target BPs in included studies. CONCLUSIONS: Self-monitoring alone is not associated with lower BP or better control, but in conjunction with co-interventions (including systematic medication titration by doctors, pharmacists, or patients; education; or lifestyle counselling) leads to clinically significant BP reduction which persists for at least 12 months. The implementation of self-monitoring in hypertension should be accompanied by such co-interventions

    Prevalence and factors affecting home blood pressure documentation in routine clinical care: a retrospective study

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Home blood pressure (BP) is closely linked to patient outcomes. However, the prevalence of its documentation has not been examined. The objective of this study was to analyze the prevalence and factors affecting documentation of home BP in routine clinical care.</p> <p>Methods</p> <p>A retrospective study of 142,973 encounters of 9,840 hypertensive patients with diabetes from 2000 to 2005 was performed. The prevalence of recorded home BP and the factors associated with its documentation were analyzed. We assessed validity of home BP information by comparing the difference between home and office BP to previously published prospective studies.</p> <p>Results</p> <p>Home BP was documented in narrative notes for 2.08% of encounters where any blood pressure was recorded and negligibly in structured data (EMR flowsheets). Systolic and diastolic home BP in narrative notes were lower than office BP readings by 9.6 and 2.5 mm Hg, respectively (p < 0.0001 for both), consistent with prospective data. Probability of home BP documentation increased by 23.0% for each 10 mm Hg of office systolic BP (p < 0.0001), by 6.2% for each $10,000 in median income of zip code (p = 0.0055), and by 17.7% for each decade in the patient's age (p < 0.0001).</p> <p>Conclusions</p> <p>Home BP readings provide a valid representation of the patient's condition, yet are seldom documented despite their potential utility in both patient care and research. Strong association between higher patient income and home BP documentation suggests that the cost of the monitors may be a limiting factor; reimbursement of home BP monitoring expenses should be pursued.</p

    Self-monitoring of blood pressure in patients with hypertension related multi-morbidity: Systematic review and individual patient data meta-analysis

    Get PDF
    BACKGROUND Studies have shown that self-monitoring of blood pressure (BP) is effective when combined with co-interventions, but its efficacy varies in the presence of some co-morbidities. This study examined whether self-monitoring can reduce clinic BP in patients with hypertension-related co-morbidity. METHODS A systematic review was conducted of articles published in Medline, Embase, and the Cochrane Library up to January 2018. Randomized controlled trials of self-monitoring of BP were selected and individual patient data (IPD) were requested. Contributing studies were prospectively categorized by whether they examined a low/high-intensity co-intervention. Change in BP and likelihood of uncontrolled BP at 12 months were examined according to number and type of hypertension-related co-morbidity in a one-stage IPD meta-analysis. RESULTS A total of 22 trials were eligible, 16 of which were able to provide IPD for the primary outcome, including 6,522 (89%) participants with follow-up data. Self-monitoring was associated with reduced clinic systolic BP compared to usual care at 12-month follow-up, regardless of the number of hypertension-related co-morbidities (−3.12 mm Hg, [95% confidence intervals −4.78, −1.46 mm Hg]; P value for interaction with number of morbidities = 0.260). Intense interventions were more effective than low-intensity interventions in patients with obesity (P < 0.001 for all outcomes), and possibly stroke (P < 0.004 for BP control outcome only), but this effect was not observed in patients with coronary heart disease, diabetes, or chronic kidney disease. CONCLUSIONS Self-monitoring lowers BP regardless of the number of hypertension-related co-morbidities, but may only be effective in conditions such obesity or stroke when combined with high-intensity co-interventions.</div

    Probing and controlling fluorescence blinking of single semiconductor nanoparticles

    Get PDF
    In this review we present an overview of the experimental and theoretical development on fluorescence intermittency (blinking) and the roles of electron transfer in semiconductor crystalline nanoparticles. Blinking is a very interesting phenomenon commonly observed in single molecule/particle experiments. Under continuous laser illumination, the fluorescence time trace of these single nanoparticles exhibit random light and dark periods. Since its first observation in the mid-1990s, this intriguing phenomenon has attracted wide attention among researchers from many disciplines. We will first present the historical background of the discovery and the observation of unusual inverse power-law dependence for the waiting time distributions of light and dark periods. Then, we will describe our theoretical modeling efforts to elucidate the causes for the power-law behavior, to probe the roles of electron transfer in blinking, and eventually to control blinking and to achieve complete suppression of the blinking, which is an annoying feature in many applications of quantum dots as light sources and fluorescence labels for biomedical imaging

    A stakeholder co-design approach for developing a community pharmacy service to enhance screening and management of atrial fibrillation

    Get PDF
    The authors would like to thank all participants in this research for their valuable input into the co-design process.Background: Community pharmacies provide a suitable setting to promote self-screening programs aimed at enhancing the early detection of atrial fibrillation (AF). Developing and implementing novel community pharmacy services (CPSs) is a complex and acknowledged challenge, which requires comprehensive planning and the participation of relevant stakeholders. Co-design processes are participatory research approaches that can enhance the development, evaluation and implementation of health services. The aim of this study was to co-design a pharmacist-led CPS aimed at enhancing self-monitoring/screening of AF. Methods: A 3-step co-design process was conducted using qualitative methods: (1) interviews and focus group with potential service users (n = 8) to identify key needs and concerns; (2) focus group with a mixed group of stakeholders (n = 8) to generate a preliminary model of the service; and (3) focus group with community pharmacy owners and managers (n = 4) to explore the feasibility and appropriateness of the model. Data were analysed qualitatively to identify themes and intersections between themes. The JeMa2 model to conceptualize pharmacybased health programs was used to build a theoretical model of the service. Results: Stakeholders delineated: a clear target population (i.e., individuals ≥65 years old, with hypertension, with or without previous AF or stroke); the components of the service (i.e., patient education; self-monitoring at home; results evaluation, referral and follow-up); and a set of circumstances that may influence the implementation of the service (e.g., quality of the service, competency of the pharmacist, inter-professional relationships, etc.). A number of strategies were recommended to enable implementation (e.g.,. endorsement by leading cardiovascular organizations, appropriate communication methods and channels between the pharmacy and the general medical practice settings, etc.). Conclusion: A novel and preliminary model of a CPS aimed at enhancing the management of AF was generated from this participatory process. This model can be used to inform decision making processes aimed at adopting and piloting of the service. It is expected the co-designed service has been adapted to suit existing needs of patients and current care practices, which, in turn, may increase the feasibility and acceptance of the service when it is implemented into a real setting.This work was funded by Covidien Pty Ltd. (Medtronic Australasia Pty Ltd) [UTS Project code: PRO16–0688], which is the company that has the rights to distribute the device Microlife BP A200 AFIB in Australia. Also, funding for this research has been provided by a UTS Chancellor’s postdoctoral fellowship awarded to the first author of this article (ID number: 2013001605)