1,457 research outputs found

    Measurement of Scintillation and Ionization Yield and Scintillation Pulse Shape from Nuclear Recoils in Liquid Argon

    Full text link
    We have measured the scintillation and ionization yield of recoiling nuclei in liquid argon as a function of applied electric field by exposing a dual-phase liquid argon time projection chamber (LAr-TPC) to a low energy pulsed narrow band neutron beam produced at the Notre Dame Institute for Structure and Nuclear Astrophysics. Liquid scintillation counters were arranged to detect and identify neutrons scattered in the TPC and to select the energy of the recoiling nuclei. We report measurements of the scintillation yields for nuclear recoils with energies from 10.3 to 57.3 keV and for median applied electric fields from 0 to 970 V/cm. For the ionization yields, we report measurements from 16.9 to 57.3 keV and for electric fields from 96.4 to 486 V/cm. We also report the observation of an anticorrelation between scintillation and ionization from nuclear recoils, which is similar to the anticorrelation between scintillation and ionization from electron recoils. Assuming that the energy loss partitions into excitons and ion pairs from 83m^{83m}Kr internal conversion electrons is comparable to that from 207^{207}Bi conversion electrons, we obtained the numbers of excitons (NexN_{ex}) and ion pairs (NiN_i) and their ratio (Nex/NiN_{ex}/N_i) produced by nuclear recoils from 16.9 to 57.3 keV. Motivated by arguments suggesting direction sensitivity in LAr-TPC signals due to columnar recombination, a comparison of the light and charge yield of recoils parallel and perpendicular to the applied electric field is presented for the first time.Comment: v2 to reflect published versio

    Antisense DNA parameters derived from next-nearest-neighbor analysis of experimental data

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The enumeration of tetrameric and other sequence motifs that are positively or negatively correlated with <it>in vivo </it>antisense DNA effects has been a useful addition to the arsenal of information needed to predict effective targets for antisense DNA control of gene expression. Such retrospective information derived from <it>in vivo </it>cellular experiments characterizes aspects of the sequence dependence of antisense inhibition that are not predicted by nearest-neighbor (NN) thermodynamic parameters derived from <it>in vitro </it>experiments. However, quantitation of the antisense contributions of motifs is problematic, since individual motifs are not isolated from the effects of neighboring nucleotides, and motifs may be overlapping. These problems are circumvented by a next-nearest-neighbor (NNN) analysis of antisense DNA effects in which the overlapping nature of nearest-neighbors is taken into account.</p> <p>Results</p> <p>Next-nearest-neighbor triplet combinations of nucleotides are the simplest that include overlapping sequence effects and therefore can encompass interactions beyond those of nearest neighbors. We used singular value decomposition (SVD) to fit experimental data from our laboratory in which phosphorothioate-modified antisense DNAs (S-DNAs) 20 nucleotides long were used to inhibit cellular protein expression in 112 experiments involving four gene targets and two cell lines. Data were fitted using a NNN model, neglecting end effects, to derive NNN inhibition parameters that could be combined to give parameters for a set of 49 sequences that represents the inhibitory effects of all possible overlapping triplet interactions in the cellular targets of these antisense S-DNAs. We also show that parameters to describe subsets of the data, such as the mRNAs being targeted and the cell lines used, can be included in such a derivation. While NNN triplet parameters provided an adequate model to fit our data, NN doublet parameters did not.</p> <p>Conclusions</p> <p>The methodology presented illustrates how NNN antisense inhibitory information can be derived from <it>in vivo </it>cellular experiments. Subsequent calculations of the antisense inhibitory parameters for any mRNA target sequence automatically take into account the effects of all possible overlapping combinations of nearest-neighbors in the sequence. This procedure is more robust than the tallying of tetrameric motifs that have positive or negative antisense effects. The specific parameters derived in this work are limited in their applicability by the relatively small database of experiments that was used in their derivation.</p

    MRI classification of interspinous ligament degeneration of the lumbar spine: intraobserver and interobserver reliability and the frequency of disagreement

    Get PDF
    Posterior spinal ligament pathology is becoming increasingly recognized as a significant cause of low back pain. Despite the growing clinical importance of interspinous ligament degeneration in low back pain patients, formal reliability studies for the magnetic resonance imaging (MRI) evaluation of interspinous ligaments have not been performed. We proposed an MRI classification system for interspinous ligament degeneration and conducted a comprehensive reliability and reproducibility assessment. Fifty patients who had low back pain with or without leg discomfort (26 males and 24 females) with a mean age of 48.8 years (range 23–85 years) were studied. The classification for lumbar interspinous ligament degeneration was developed on the basis of the literature using mid-sagittal T1- and T2-weighted images. Three spine surgeons independently graded a total of 200 interspinous ligament levels. Intraobserver and interobserver reliability were assessed by kappa statistics. The frequency of disagreement was also identified. The intraobserver agreement was excellent in all readers (kappa range 0.840–0.901). The interobserver agreement was lower as expected, and was substantial to excellent (kappa range 0.726–0.818). Overall complete agreement was obtained in 87.8% of all interspinous ligament levels. A difference of 1, 2, and 3 grades occurred in 8.1, 3.0, and 1.1% of readings, respectively. This proposed MRI classification of interspinous ligament degeneration was simple, reliable, and reproducible. Its use as a standardized nomenclature in clinical and radiographic research may be recommended

    Tiny cystine stones in the gallbladder of a patient with cholecystolithiasis complicating acute cholecystitis: a case report

    Get PDF
    Cystine stones, the main component of which is cystine, are very common urinary calculi, but are rare in the gall bladder. In animals, there has been only one report of cystine gallstones in tree shrews, and to our knowledge, this is the first report of cystine gallstones in humans

    Tumor Necrosis Factor-Alpha G308α Gene Polymorphism and Essential Hypertension: A Meta-Analysis Involving 2244 Participants

    Get PDF
    BACKGROUND: The tumor necrosis factor-alpha (TNFα) G308A gene polymorphism has been implicated in susceptibility to essential hypertension (EH), but study results are still controversial. OBJECTIVE AND METHODS: The present meta-analysis is performed to investigate the relationship between the TNFα G308A gene polymorphism and EH. Electronic databases were searched and seven separate studies on the association of the TNF α G308A gene polymorphism with EH were analyzed. The meta-analysis involved 1092 EH patients and 1152 controls. The pooled odds ratios (ORs) and their corresponding 95% confidence interval (CI) were calculated by a fixed or random effect model. RESULTS: A significant relationship between the TNFα G308A gene polymorphism and EH was found in an allelic genetic model (OR: 1.45, 95% CI: 1.17 to 1.80, P = 0.0008), a recessive genetic model (OR: 3.181, 95% CI: 1.204 to 8.408, P = 0.02), and a homozygote model (OR: 3.454, 95% CI: 1.286 to 9.278, P = 0.014). No significant association between them was detected in both a dominant genetic model (OR: 1.55, 95% CI: 0.99 to 2.42, P = 0.06) or a heterozygote genetic model (OR: 1.45, 95% CI: 0.90 to 2.33, P = 0.13). CONCLUSION: The TNFα G308A gene polymorphism is associated with EH susceptibility

    Three little pieces for computer and relativity

    Full text link
    Numerical relativity has made big strides over the last decade. A number of problems that have plagued the field for years have now been mostly solved. This progress has transformed numerical relativity into a powerful tool to explore fundamental problems in physics and astrophysics, and I present here three representative examples. These "three little pieces" reflect a personal choice and describe work that I am particularly familiar with. However, many more examples could be made.Comment: 42 pages, 11 figures. Plenary talk at "Relativity and Gravitation: 100 Years after Einstein in Prague", June 25 - 29, 2012, Prague, Czech Republic. To appear in the Proceedings (Edition Open Access). Collects results appeared in journal articles [72,73, 122-124

    Alumina-on-alumina total hip replacement for femoral neck fracture in healthy patients

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Total hip replacement is considered the best option for treatment of displaced intracapsular fractures of the femoral neck (FFN). The size of the femoral head is an important factor that influences the outcome of a total hip arthroplasty (THA): implants with a 28 mm femoral head are more prone to dislocate than implants with a 32 mm head. Obviously, a large head coupled to a polyethylene inlay can lead to more wear, osteolysis and failure of the implant. Ceramic induces less friction and minimal wear even with larger heads.</p> <p>Methods</p> <p>A total of 35 THAs were performed for displaced intracapsular FFN, using a 32 mm alumina-alumina coupling.</p> <p>Results</p> <p>At a mean follow-up of 80 months, 33 have been clinically and radiologically reviewed. None of the implants needed revision for any reason, none of the cups were considered to have failed, no dislocations nor breakage of the ceramic components were recorded. One anatomic cementless stem was radiologically loose.</p> <p>Conclusions</p> <p>On the basis of our experience, we suggest that ceramic-on-ceramic coupling offers minimal friction and wear even with large heads.</p