76 research outputs found

    Neutrinos

    Get PDF
    229 pages229 pages229 pagesThe Proceedings of the 2011 workshop on Fundamental Physics at the Intensity Frontier. Science opportunities at the intensity frontier are identified and described in the areas of heavy quarks, charged leptons, neutrinos, proton decay, new light weakly-coupled particles, and nucleons, nuclei, and atoms

    The LUX-ZEPLIN (LZ) Experiment

    Get PDF
    We describe the design and assembly of the LUX-ZEPLIN experiment, a direct detection search for cosmic WIMP dark matter particles. The centerpiece of the experiment is a large liquid xenon time projection chamber sensitive to low energy nuclear recoils. Rejection of backgrounds is enhanced by a Xe skin veto detector and by a liquid scintillator Outer Detector loaded with gadolinium for efficient neutron capture and tagging. LZ is located in the Davis Cavern at the 4850' level of the Sanford Underground Research Facility in Lead, South Dakota, USA. We describe the major subsystems of the experiment and its key design features and requirements

    LUX-ZEPLIN (LZ) Technical Design Report

    Get PDF
    In this Technical Design Report (TDR) we describe the LZ detector to be built at the Sanford Underground Research Facility (SURF). The LZ dark matter experiment is designed to achieve sensitivity to a WIMP-nucleon spin-independent cross section of three times ten to the negative forty-eighth square centimeters

    Reclaiming the child left behind: the case for corporate cultural responsibility

    Get PDF
    Although a reasonable understanding of corporate social responsibility (CSR) exists, one dimension remains largely ignored. That is, the cultural impacts of corporations, or the bearing, at various levels of their business models, activities, and outcomes on the value systems and enduring beliefs of affected people. We introduce the notion of corporate cultural responsibility (CCR). The way corporations address CCR concerns can be reflected according to three stances: cultural destructiveness, cultural carelessness, and cultural prowess. Taken sequentially, they reflect a growing comprehension and increasingly active consideration of CCR concerns by corporations. In turn, we explicitly address issues related to the complex question of determining the cultural responsibilities of corporate actors; specify key CCR-related conceptualizations; and lay a foundation for discussions, debates, and research efforts centered on CCR concerns and rationales

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    Get PDF
    LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above 1.4×10−48cm2 for a WIMP mass of 40GeV/c2 and a 1000days exposure. LZ achieves this sensitivity through a combination of a large 5.6t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented

    The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

    Get PDF

    Letters to the Editor

    No full text

    Recent Advances in Immediate Toe-to-Hand Transfer

    No full text

    Vascularized Nerve Grafts and Vascularized Fascia for Upper Extremity Nerve Reconstruction

    No full text
    Since 1976, experimental and clinical studies have suggested the superiority of vascularized nerve grafts. In this study, a 27-year experience of the senior author is presented regarding vascularized nerve grafts and fascia for complex upper extremity nerve reconstruction. The factors influencing outcomes as well as a comparison with conventional nerve grafts is presented. Since 1981, 21 vascularized nerve grafts, other than vascularized ulnar nerve, were used for reconstruction of nerve injuries in the upper extremity. Indications were prolonged denervation time, failure of the previously used conventional nerve grafts, and excessive scar in the recipient site. Injury was in the hand/wrist area (n = 5), in the forearm (n = 4), in the elbow (n = 2), in the arm (n = 4), or in the plexus (n = 6). Vascularized sural (n = 9), saphenous (n = 8), superficial radial (n = 3), and peroneal (superficial and deep) nerves were used. The mean follow-up was 31.4 months. Vascularized nerve grafts for upper extremity injuries provided good to excellent sensory return in severely scarred upper extremities in patients in whom conventional nerve grafts had failed. They have also provided relief of causalgia after painful neuroma resection and motor function recovery in selective cases even for above the elbow injuries. Small diameter vascularized nerve grafts should be considered for bridging long nerve gaps in regions of excessive scar or for reconstructions where conventional nerve grafts have failed
    • …
    corecore