623 research outputs found
The incidence of total hip arthroplasty after hip arthroscopy in osteoarthritic patients
<p>Abstract</p> <p>Objective</p> <p>To assess the incidence of total hip arthroplasty (THA) in osteoarthritic patients who were treated by arthroscopic debridement and to evaluate factors that might influence the time interval from the first hip arthroscopy to THA.</p> <p>Design</p> <p>Retrospective clinical series</p> <p>Methods</p> <p>Follow-up data and surgical reports were retrieved from 564 records of osteoarthritic patients that have had hip arthroscopy between the years 2002 to 2009 with a mean follow-up time of 3.2 years (range, 1-6.4 years). The time interval between the first hip arthroscopy to THA was modelled as a function of patient age; level of cartilage damage; procedures performed and repeated arthroscopies with the use of multivariate regression analysis.</p> <p>Results</p> <p>Ninety (16%) of all participants eventually required THA. The awaiting time from the first arthroscopy to a hip replacement was found to be longer in patients younger than 55 years and in a milder osteoarthritic stage. Patients that experienced repeated hip scopes had a longer time to THA than those with only a single procedure. Procedures performed concomitant with debridement and lavage did not affect the time interval to THA.</p> <p>Conclusions</p> <p>In our series of arthroscopic treatment of hip osteoarthritis, 16% required THA over a period of 7 years. Factors that influence the time to arthroplasty were age, degree of osteoarthritis and recurrent procedures.</p
Incidence of premature battery depletion in subcutaneous cardioverter-defibrillator patients: insights from a multicenter registry.
BACKGROUND
The subcutaneous ICD established its role in the prevention of sudden cardiac death in recent years. The occurrence of premature battery depletion in a large subset of potentially affected devices has been a cause of concern. The incidence of premature battery depletion has not been studied systematically beyond manufacturer-reported data.
METHODS
Retrospective data and the most recent follow-up data on S-ICD devices from fourteen centers in Europe, the US, and Canada was studied. The incidence of generator removal or failure was reported to investigate the incidence of premature S-ICD battery depletion, defined as battery failure within 60 months or less.
RESULTS
Data from 1054 devices was analyzed. Premature battery depletion occurred in 3.5% of potentially affected devices over an observation period of 49 months.
CONCLUSIONS
The incidence of premature battery depletion of S-ICD potentially affected by a battery advisory was around 3.5% after 4 years in this study. Premature depletion occurred exclusively in devices under advisory. This is in line with the most recently published reports from the manufacturer.
TRIAL REGISTRATION
ClinicalTrials.gov Identifier: NCT04767516
Intracapsular pressure and interleukin-1ÎČ cytokine in hips with acetabular dysplasia
Background and purpose Several studies have demonstrated an increased intracapsular pressure in several hip disorders such as septic arthritis, synovitis, and trauma. We therefore measured the intracapsular pressure in different positions in early dysplasic hips and its relation to the concentration of interleukin-1ÎČ (IL-1ÎČ), the volume of joint fluid, and the clinical and radiographic findings before a periacetabular osteotomy
Book Reviews
With the observation of high-energy astrophysical neutrinos by the IceCube Neutrino Observatory, interest has risen in models of PeV-mass decaying dark matter particles to explain the observed flux. We present two dedicated experimental analyses to test this hypothesis. One analysis uses 6 years of IceCube data focusing on muon neutrino âtrackâ events from the Northern Hemisphere, while the second analysis uses 2 years of âcascadeâ events from the full sky. Known background components and the hypothetical flux from unstable dark matter are fitted to the experimental data. Since no significant excess is observed in either analysis, lower limits on the lifetime of dark matter particles are derived: we obtain the strongest constraint to date, excluding lifetimes shorter than s at 90% CL for dark matter masses above 10 TeV
The ANTARES Collaboration: Contributions to ICRC 2017 Part I: Neutrino astronomy (diffuse fluxes and point sources)
Papers on neutrino astronomy (diffuse fluxes and point sources, prepared for
the 35th International Cosmic Ray Conference (ICRC 2017, Busan, South Korea) by
the ANTARES Collaboratio
All-sky Search for High-Energy Neutrinos from Gravitational Wave Event GW170104 with the ANTARES Neutrino Telescope
Advanced LIGO detected a significant gravitational wave signal (GW170104)
originating from the coalescence of two black holes during the second
observation run on January 4, 2017. An all-sky high-energy
neutrino follow-up search has been made using data from the ANTARES neutrino
telescope, including both upgoing and downgoing events in two separate
analyses. No neutrino candidates were found within s around the GW
event time nor any time clustering of events over an extended time window of
months. The non-detection is used to constrain isotropic-equivalent
high-energy neutrino emission from GW170104 to less than
erg for a spectrum
The Antares Collaboration : Contributions to the 34th International Cosmic Ray Conference (ICRC 2015, The Hague)
The ANTARES detector, completed in 2008, is the largest neutrino telescope in the Northern hemisphere. Located at a depth of 2.5 km in the Mediterranean Sea, 40 km off the Toulon shore, its main goal is the search for astrophysical high energy neutrinos. In this paper we collect the 21 contributions of the ANTARES collaboration to the 34th International Cosmic Ray Conference (ICRC 2015). The scientific output is very rich and the contributions included in these proceedings cover the main physics results, ranging from steady point sources, diffuse searches, multi-messenger analyses to exotic physics
The ANTARES Collaboration: Contributions to ICRC 2017 Part III: Searches for dark matter and exotics, neutrino oscillations and detector calibration
Papers on the searches for dark matter and exotics, neutrino oscillations and
detector calibration, prepared for the 35th International Cosmic Ray Conference
(ICRC 2017, Busan, South Korea) by the ANTARES Collaboratio
The ANTARES Collaboration: Contributions to ICRC 2017 Part II: The multi-messenger program
Papers on the ANTARES multi-messenger program, prepared for the 35th
International Cosmic Ray Conference (ICRC 2017, Busan, South Korea) by the
ANTARES Collaboratio
Neutrinos below 100 TeV from the southern sky employing refined veto techniques to IceCube data
Many Galactic sources of gamma rays, such as supernova remnants, are expected
to produce neutrinos with a typical energy cutoff well below 100 TeV. For the
IceCube Neutrino Observatory located at the South Pole, the southern sky,
containing the inner part of the Galactic plane and the Galactic Center, is a
particularly challenging region at these energies, because of the large
background of atmospheric muons. In this paper, we present recent advancements
in data selection strategies for track-like muon neutrino events with energies
below 100 TeV from the southern sky. The strategies utilize the outer detector
regions as veto and features of the signal pattern to reduce the background of
atmospheric muons to a level which, for the first time, allows IceCube
searching for point-like sources of neutrinos in the southern sky at energies
between 100 GeV and several TeV in the muon neutrino charged current channel.
No significant clustering of neutrinos above background expectation was
observed in four years of data recorded with the completed IceCube detector.
Upper limits on the neutrino flux for a number of spectral hypotheses are
reported for a list of astrophysical objects in the southern hemisphere.Comment: 19 pages, 17 figures, 2 table
- âŠ