5,168 research outputs found
The CEDAR Project
We describe the plans and objectives of the CEDAR project (Combined e-Science
Data Analysis Resource for High Energy Physics) newly funded by the PPARC
e-Science programme in the UK. CEDAR will combine the strengths of the well
established and widely used HEPDATA database of HEP data and the innovative
JetWeb data/Monte Carlo comparison facility, built on the HZTOOL package, and
will exploit developing grid technology. The current status and future plans of
both of these individual sub-projects within the CEDAR framework are described,
showing how they will cohesively provide (a) an extensive archive of Reaction
Data, (b) validation and tuning of Monte Carlo programs against these reaction
data sets, and (c) a validated code repository for a wide range of HEP code
such as parton distribution functions and other calculation codes used by
particle physicists. Once established it is envisaged CEDAR will become an
important Grid tool used by LHC experimentalists in their analyses and may well
serve as a model in other branches of science where there is a need to compare
data and complex simulations.Comment: 4 pages, 4 postscript figures, uses CHEP2004.cls. Presented at
Computing in High-Energy Physics (CHEP'04), Interlaken, Switzerland, 27th
September - 1st October 200
HepForge: A lightweight development environment for HEP software
Setting up the infrastructure to manage a software project can become a task
as significant writing the software itself. A variety of useful open source
tools are available, such as Web-based viewers for version control systems,
"wikis" for collaborative discussions and bug-tracking systems, but their use
in high-energy physics, outside large collaborations, is insubstantial.
Understandably, physicists would rather do physics than configure project
management tools.
We introduce the CEDAR HepForge system, which provides a lightweight
development environment for HEP software. Services available as part of
HepForge include the above-mentioned tools as well as mailing lists, shell
accounts, archiving of releases and low-maintenance Web space. HepForge also
exists to promote best-practice software development methods and to provide a
central repository for re-usable HEP software and phenomenology codes.Comment: 3 pages, 0 figures. To be published in proceedings of CHEP06. Refers
to the HepForge facility at http://hepforge.cedar.ac.u
HepData and JetWeb: HEP data archiving and model validation
The CEDAR collaboration is extending and combining the JetWeb and HepData
systems to provide a single service for tuning and validating models of
high-energy physics processes. The centrepiece of this activity is the fitting
by JetWeb of observables computed from Monte Carlo event generator events
against their experimentally determined distributions, as stored in HepData.
Caching the results of the JetWeb simulation and comparison stages provides a
single cumulative database of event generator tunings, fitted against a wide
range of experimental quantities. An important feature of this integration is a
family of XML data formats, called HepML.Comment: 4 pages, 0 figures. To be published in proceedings of CHEP0
Variability of subtropical upper tropospheric humidity
International audienceAnalysis of Atmospheric Infrared Sounder (AIRS) measurements for five northern winters shows significant longitudinal variations in subtropical upper tropospheric relative humidity (RH), not only in the climatological mean values but also in the local distributions and temporal variability. The largest climatological mean values in the northern subtropics occur over the eastern Pacific and Atlantic oceans, where there is also large day-to-day variability. In contrast, there are smaller mean values, and smaller variability that occurs at lower frequency, over the Indian and western Pacific oceans. These differences in the distribution and variability of subtropical RH are related to differences in the key transport processes in the different sectors. The large variability and intermittent high and low RH over the Eastern Pacific and Atlantic oceans, and to a smaller extent over the Indian ocean, are due to intrusions of high potential vorticity air into the subtropics. Intrusions seldom occur over the eastern Indian and western Pacific oceans, and here the subtropical RH is more closely linked to the location and strength of subtropical anticyclones. In this region there are eastward propagating features in the subtropical RH that are out of phase with the tropical RH, and are caused by modulation of the subtropical anticyclones by the Madden-Julian Oscillation
Epitaxial Growth of LaSrFeO thin films by laser ablation
We report on the synthesis of high quality LaSrFeO (LSFO)
thin films using the pulsed laser deposition technique on both SrTiO (STO)
and LaAlO (LAO) substrates (100)-oriented. From X-Ray diffraction (XRD)
studies, we find that the films have an out-of-plane lattice parameter around
0.3865nm, almost independent of the substrate (i.e. the nature of the strains).
The transport properties reveal that, while LSFO films deposited on STO exhibit
an anomaly in the resistivity vs temperature at 180K (corresponding to the
charge-ordered transition and associated with a transition from a paramagnetic
to an antiferromagnetic state), the films grown on LAO display a very small
magnetoresistance behavior and present an hysteresis around 270K under the
application of a 4T magnetic field. The changes in transport properties between
both substrates are discussed and compared with the corresponding single
crystals.Comment: 9 pages, 4 figure
Multi-Model Assessment of the Factors Driving the Ozone Evolution Over the 21st Century
The evolution of ozone from 1960 to 2100 is examined in simulations from fourteen chemistry-climate models. There is general agreement among the models at the broadest levels, with all showing column ozone decreasing at all latitudes from 1960 to around 2000, then increasing at all latitudes over the first half of the 21 st century (21 C), and latitudinal variations in the rate of increase and date of return to historical values. In the second half of the century, ozone is projected to carry on increasing, level off or even decrease depending on the latitude, resulting in variable dates of return to historical values at latitudes where column ozone has declined below those levels. Separation into partial column above and below 20 hPa reveals that these latitudinal differences are almost completely due to differences in the lower stratosphere. At all latitudes, upper stratospheric ozone increases throughout the 21 C and returns to 1960 levels before the end of the century, although there is a spread among the models in dates that ozone returns to historical values. Using multiple linear regression the upper stratospheric ozone increase comes from almost equal contributions due to decrease in halogens and cooling from increased greenhouse gas concentrations. The evolution of lower stratospheric ozone differs with latitude. In the tropical lower stratosphere an increase in tropical upwelling causes a steady decrease in ozone through the 21C, and total column ozone does not return to 1960 levels in all models. In contrast, lower stratospheric and total column ozone in middle and high latitudes increases during the 21 C and returns to 1960 levels. For all models there is an earlier return for ozone to historical levels in the northern hemisphere. This is thought to be due to interhemispheric differences in transport
Novel Signal Noise Reduction Method through Cluster Analysis, Applied to Photoplethysmography
Physiological signals can often become contaminated by noise from a variety of origins. In this paper, an algorithm is described for the reduction of sporadic noise from a continuous periodic signal. The design can be used where a sample of a periodic signal is required, for example, when an average pulse is needed for pulse wave analysis and characterization. The algorithm is based on cluster analysis for selecting similar repetitions or pulses from a periodic single. This method selects individual pulses without noise, returns a clean pulse signal, and terminates when a sufficiently clean and representative signal is received. The algorithm is designed to be sufficiently compact to be implemented on a microcontroller embedded within a medical device. It has been validated through the removal of noise from an exemplar photoplethysmography (PPG) signal, showing increasing benefit as the noise contamination of the signal increases. The algorithm design is generalised to be applicable for a wide range of physiological (physical) signals
- …