411 research outputs found

    Gamma rays of 0.3 to 30 MeV from PSR 0531+21

    Get PDF
    Pulsed gamma rays from the Crab Pulsar PSR 0531+21 are reported for energies of 0.3 to 30 MeV. The observations were carried out with the UCR gamma ray double Compton scatter telescope launched on a balloon from Palestine, Texas at 4.5 GV, at 2200 LT, September 29, 1978. Two 8 hr observations of the pulsar were made, the first starting at 0700 UT (0200 LT) September 30 just after reaching float altitude of 4.5 g/sq cm. Analysis of the total gamma ray flux from the Crab Nebula plus pulsar using telescope vertical cell pairs was published previously. The results presented supersede the preliminary ones. The double scatter mode of the UCR telescope measures the energy of each incident gamma ray from 1 to 30 MeV and its incident angle to a ring on the sky. The time of arrival is measured to 0.05 ms. The direction of the source is obtained from overlapping rings on the sky. The count rate of the first scatter above a threshold of 0.3 MeV is recorded every 5.12 ms. The Crab Pulsar parameters were determined from six topocentric arrival times of optical pulses

    Measured performance of the new University of California gamma ray telescope

    Get PDF
    The design of the new medium energy balloon-borne gamma ray telescope is discussed. This telescope is sensitive to 1-30 MeV gamma rays. The results of the initial calibration are described. The position and energy resolutions of 32 plastic and NaI(Tl) scintillator bars, each 100 cm long are discussed. The telescope's measured angular and energy resolutions as a function of incident angle are compared with detailed Monte Carlo calculations at 1.37, 2.75 and 6.13 MeV. The expected resolutions are 5 deg FHWM and 8% at 2.75 MeV. The expected area-efficiency is 250 cm

    Inhomogeneity of donor doping in SrTiO3 substrates studied by fluorescence-lifetime imaging microscopy

    Get PDF
    Fluorescence-lifetime imaging microscopy (FLIM) was applied to investigate the donor distribution in SrTiO3 single crystals. On the surfaces of Nb- and La-doped SrTiO3, structures with different fluorescence intensities and lifetimes were found that could be related to different concentrations of Ti3+. Furthermore, the inhomogeneous distribution of donors caused a non-uniform conductivity of the surface, which complicates the production of potential electronic devices by the deposition of oxide thin films on top of doped single crystals. Hence, we propose FLIM as a convenient technique (length scale: 1 μ\mum) for characterizing the quality of doped oxide surfaces, which could help to identify appropriate substrate materials

    Modeling the Redshift Evolution of the Normal Galaxy X-ray Luminosity Function

    Get PDF
    Emission from X-ray binaries (XRBs) is a major component of the total X-ray luminosity of normal galaxies, so X-ray studies of high redshift galaxies allow us to probe the formation and evolution of X-ray binaries on very long timescales. In this paper, we present results from large-scale population synthesis models of binary populations in galaxies from z = 0 to 20. We use as input into our modeling the Millennium II Cosmological Simulation and the updated semi-analytic galaxy catalog by Guo et al. (2011) to self-consistently account for the star formation history (SFH) and metallicity evolution of each galaxy. We run a grid of 192 models, varying all the parameters known from previous studies to affect the evolution of XRBs. We use our models and observationally derived prescriptions for hot gas emission to create theoretical galaxy X-ray luminosity functions (XLFs) for several redshift bins. Models with low CE efficiencies, a 50% twins mass ratio distribution, a steeper IMF exponent, and high stellar wind mass loss rates best match observational results from Tzanavaris & Georgantopoulos (2008), though they significantly underproduce bright early-type and very bright (Lx > 10d41) late-type galaxies. These discrepancies are likely caused by uncertainties in hot gas emission and SFHs, AGN contamination, and a lack of dynamically formed Low-mass XRBs. In our highest likelihood models, we find that hot gas emission dominates the emission for most bright galaxies. We also find that the evolution of the normal galaxy X-ray luminosity density out to z = 4 is driven largely by XRBs in galaxies with X-ray luminosities between 10d40 and 10d41 erg/s.Comment: Accepted into ApJ, 17 pages, 3 tables, 7 figures. Text updated to address referee's comment

    The Coincidence of Nuclear Star Clusters and Active Galactic Nuclei

    Get PDF
    We study galaxies that host both nuclear star clusters and active galactic nuclei (AGN) implying the presence of a massive black hole. We select a sample of 176 galaxies with previously detected nuclear star clusters that range from ellipticals to late-type spirals. We search for AGN in this sample using optical spectroscopy and archival radio and X-ray data. We find galaxies of all Hubble types and with a wide range of masses (10^9-11 solar masses) hosting both AGN and nuclear star clusters. From the optical spectra, we classify 10% of the galaxies as AGN and an additional 15% as composite, indicating a mix of AGN and star-formation spectra. The fraction of nucleated galaxies with AGN increases strongly as a function of galaxy and nuclear star cluster mass. For galaxies with both a NC and a black hole, we find that the masses of these two objects are quite similar. However, non-detections of black holes in Local Group nuclear star clusters show that not all clusters host black holes of similar masses. We discuss the implications of our results for the formation of nuclear star clusters and massive black holes.Comment: Accepted for publication in ApJ. Version with high resolution figures available at http://www.cfa.harvard.edu/~aseth/nsc_agn_paper.pd

    The TIGRE gamma-ray telescope

    Get PDF
    TIGRE is an advanced telescope for gamma-ray astronomy with a few arcmin resolution. From 0.3 to 10 MeV it is a Compton telescope. Above 1 MeV, its multi-layers of double sided silicon strip detectors allow for Compton recoil electron tracking and the unique determination for incident photon direction. From 10 to 100 MeV the tracking feature is utilized for gamma-ray pair event reconstruction. Here we present TIGRE energy resolutions, background simulations and the development of the electronics readout system

    Distribution of microelements in human articular cartilage : initial report

    Get PDF
    The aim of this study was evaluation of distribution microelements in human articular cartilage and to determine factors influencing it. The following elements were taken under consideration: Mg, Ca, Zn, Fe, Pb. Their concentration was assessed in the articular cartilage harvested from the loaded an unloaded area of human femoral heads. Initial results indicate that mechanical loadings are one of the important factors influencing distribution of microelements in human articular cartilage
    corecore