    A rotating double-headed positron camera

    Get PDF
    Based on a double-headed rotating uncollimated scintillation camera system, a positron imaging device was developed. After a rotating data acquisition in coincidence mode, 16 transverse section images are reconstructed by back projection. To obtain a uniform response, a limited angle reconstruction option is incorporated in this process. After correction for the system response by a three-dimensional deconvolution technique, the 16 transverse section images are stored on disk as a standard patient study for further analysis. The system can also be operated in a stationary mode. In this mode longitudinal tomographic images are obtained. Return to single photon scintigraphy is possible by remounting the collimators and by switching off the coincidence electronics

    Use of infrared thermography in the detection of superficial phlebitis in adult intensive care unit patients:A prospective single-center observational study

    Get PDF
    Common methods to detect phlebitis may not be sufficient for patients in the intensive care unit (ICU). The goal of this study was to investigate the feasibility of infrared (IR) thermography to objectively detect phlebitis in adult ICU patients. We included a total of 128 adult ICU-patients in a pilot and subsequent validation study. Median [interquartile range] age was 62 [54-71] years and 88 (69%) patients were male. Severity of phlebitis was scored using the visual infusion phlebitis (VIP)-score, ranging from 0 (no phlebitis) to 5 (thrombophlebitis). The temperature difference (ΔT) between the insertion site and a proximal reference point was measured with IR thermography. In 78 (34%) catheters early phlebitis and onset of moderate phlebitis was observed (VIP-score of 1-3). In both the pilot and the validation study groups ΔT was significantly higher when the VIP-score was ≥1 compared to a VIP-score of 0 (p<0.01 and p<0.001, respectively). Multivariate analysis identified ΔT (p<0.001) and peripheral venous catheter (PVC) dwell time (p = 0.001) as significantly associated with phlebitis. IR thermography may be a promising technique to identify phlebitis in the ICU. An increased ΔT as determined with thermography may be a risk factor for phlebitis

    Imaging beta-adrenoceptors in the human brain with (S)-1'-[F-18]fluorocarazolol

    Get PDF
    We evaluated the suitability of fluorocarazolol for in vivo studies of cerebral beta-adrenoceptors because (S)-1'-[F-18]fluorocarazolol has a higher affinity to beta-adrenoceptors than to serotonergic receptors (pK(i) beta(1) 9.4, beta(2) 10.0, 5HT(1A) 7.4, 5HT(1B) 8.1) and rapidly crosses the blood-brain barrier. Methods: The (S)-[F-18]fluorocarazolol (74 MBq, >37 TBq/mmol) was intravenously administered to healthy volunteers on two separate occasions with an interval of at least 1 wk, The initial injection was without pretreatment, but before the second injection, the volunteers received the beta blocker (+/-)-pindolol (3 x 5 mg orally, during 18 hr). The brain was studied with a PET camera in dynamic mode. Results: Uptake of radioactivity delineated gray matter and was particularly high in the posterior cingulate, precuneus and striatum, Low uptake occurred in the thalamus, whereas the lowest uptake was observed in the white matter of the corpus callosum. After pindolol pretreatment, uptake was reduced and its distribution became homogeneous throughout the brain, The ratio of total-to-nonspecific binding was about 2 at 60 min, increasing to 2.5-2.75 at longer intervals. Conclusion: Fluorocarazolol is the first radioligand that can visualize cerebral beta-adrenoceptors and may enable monitoring of these binding sites during disease
    • …
    corecore