    Combined transbrachial and transfemoral strategy to deploy an iliac branch endoprosthesis in the setting of a pre-existing endovascular aortic aneurysm repair

    Get PDF
    This article describes brachial access to position a long sheath in the abdominal aorta in conjunction with a large caliber sheath via the femoral artery ipsilateral to the target site to deliver a 0.018 bodyfloss wire. This bodyfloss wire is inserted into the precannulation port of the iliac branch endoprosthesis (W. L. Gore and Associates, Flagstaff, Ariz), which is then advanced from the groin. Once the bifurcated device is deployed, hypogastric access and stenting is achieved from the upper extremity. This technique is an alternative to safely extend the distal seal while preserving the hypogastric artery and has the advantage of limited iliac bifurcation manipulation

    Worldwide Disparities in Recovery of Cardiac Testing 1 Year Into COVID-19

    Get PDF
    FUNDING SUPPORT AND AUTHOR DISCLOSURES Dr Williams is supported by the British Heart Foundation (FS/ICRF/ 20/26002). Dr Einstein has received speaker fees from Ionetix; has received consulting fees from W. L. Gore & Associates; has received authorship fees from Wolters Kluwer Healthcare – UpToDate; and has received grants or grants pending to his institution from Attralus, Canon Medical Systems, Eidos Therapeutics, GE Healthcare, Pfizer, Roche Medical Systems, W. L. Gore & Associates, and XyloCor Ther- apeutics. Dr Williams has received speaker fees from Canon Medical Systems. Dr Dorbala has received honoraria from Pfizer and GE Healthcare; and has received grants to her institution from Pfizer and GE Healthcare. Dr Sinitsyn has received congress speaker honoraria from Bayer, GE Healthcare, Siemens, and Philips. Dr Kudo has received research grants from Nihon Medi-physics and FUJIFILM Toyama Chemical. Dr Bucciarelli-Ducci is CEO (part-time) of the So- ciety for Cardiovascular Magnetic Resonance; and has received speaker fees from Circle Cardiovascular Imaging, Bayer, and Siemens Healthineers. All other authors have reported that they have no re- lationships relevant to the contents of this paper to disclose.Peer reviewedPublisher PD

    Late Gore Excluder endoprosthesis fabric tear leading to abdominal aortic aneurysm rupture 5 years after initial implant

    Get PDF
    Endoprosthesis fabric tear leading to abdominal aortic aneurysm rupture is a rare event. In this report, we describe a patient who presented with an abdominal aortic aneurysm rupture after a tear in the fabric of the Gore Excluder endoprosthesis (W. L. Gore and Associationes, Flagstaff, Ariz) 5 years after implantation. The reason for the fabric tear was unknown. The complication was successfully treated by relining the endograft with an aortic cuff and two iliac limbs. The patient experienced an uneventful recovery after the intervention

    Paper #2-16 BIODIVERSITY MANAGEMENT AND TECHNOLOGY Prepared by the Technology Subgroup

    Get PDF
    and Oil Resources, also approved the making available of certain materials used in the study process, including detailed, specific subject matter papers prepared or used by the study’s Task Groups and/or Subgroups. These Topic and White Papers were working documents that were part of the analyses that led to development of the summary results presented in the report’s Executive Summary and Chapters. These Topic and White Papers represent the views and conclusions of the authors. The National Petroleum Council has not endorsed or approved the statements and conclusions contained in these documents, but approved the publication of these materials as part of the study process. The NPC believes that these papers will be of interest to the readers of the report and will help them better understand the results. These materials are being made available in the interest of transparency. The attached paper is one of 57 such working documents used in the study analyses. Also included is a roster of the Subgroup that developed or submitted this paper. Appendix C of the final NPC report provides a complete list of the 57 Topic and Whit

    Successful treatment of endotension and aneurysm sac enlargement with endovascular stent graft reinforcement

    Get PDF
    Abdominal aortic aneurysm (AAA) enlarges after successful endovascular repair because of endoleak, which is persistent blood flow within the aneurysm sac. In the absence of detectable endoleak, AAA may still expand, in part because of endotension, which is persistent pressurization within the excluded aneurysm. We report three patients who underwent successful endovascular AAA repair using the Excluder device (W. L. Gore & Associates, Flagstaff, Ariz). Although their postoperative surveillance showed an initial aneurysm regression, delayed aneurysm enlargement developed in all three, apparently due to endotension. Endovascular treatment was performed in which endograft reinforcement with a combination of aortic cuff and iliac endograft extenders were inserted in the previously implanted stent grafts. The endograft reinforcement procedure successfully resulted in aneurysm sac regression in all three patients. Our study underscores the significance of increased graft permeability as a mechanism of endotension and delayed aneurysm enlargement after successful endovascular AAA repair. In addition, our cases illustrate the feasibility and efficacy of an endovascular treatment strategy when endotension and aneurysm sac enlargement develops after endovascular AAA repair

    The stent graft barnacle - edge hyperplasia following femoral artery implant in a young female

    Get PDF
    A 37-year-old female underwent an emergent implant of a covered self-expandable stent graft (8mm x 10cm Viabahn, W. L. Gore) due to acute bleeding from a femoral access following closure of a patent foramen ovale. Over the following months, intermittent claudication developed, progressively more incapacitant. Work-up revealed near-occlusion of the stent graft due to edge stenosis. Elective explant of the stent graft was performed, revealing extensive proximal and distal edge miointimal hyperplasia (marked with *). Endarterectomy was performed and the arterial defect was corrected with a bovine pericardium patch

    Delegated job design

    Get PDF
    We develop a theory of delegation within organizations where agents are privately informed about whether they should be engaged in exploitation or in exploration activities. Excessive delegation lead agents to inefficiently herd into exploration in an attempt to boost their market value. The theory is consistent with both high-delegation practices and practices where agents are assigned to activities. Our main result is that an agent should be delegated more the weaker career concerns, a variable that is made endogenous through the firm's technology and its degree of transparency. The theory sheds light on empirical regularities that are previously unexplained, such as a positive relation between wages and delegation, and delegation being more prevalent in closed environments or environments with long-term employment contracts

    Emergent endovascular treatment options for thoracoabdominal aortic aneurysm

    Get PDF
    For a long time, parallel grafting, physician-modified endografts, and, more recently, in situ fenestration were the only go-to endovascular options for ruptured thoracoabdominal aortic aneurysm, offered mixed results, and depended mainly on the operator's and center's experience. As custom-made devices have become an established endovascular treatment option for elective thoracoabdominal aortic aneurysm, they are not a viable option in the emergency setting, as endograft production can take up to 4 months. The development of off-the-shelf (OTS) multibranched devices with a standardized configuration has allowed the treatment of ruptured thoracoabdominal aortic aneurysm with emergent branched endovascular procedures. The Zenith t-Branch device (Cook Medical) was the first readily available graft outside the United States to receive the CE mark (in 2012) and is currently the most studied device for those indications. A new device, the E-nside thoracoabdominal branch endoprosthesis OTS multibranched endograft (Artivion), has been made commercially available, and the GORE EXCLUDER thoracoabdominal branch endoprosthesis OTS multibranched endograft (W. L. Gore and Associates) is expected to be released in 2023. Due to the lack of guidelines on ruptured thoracoabdominal aortic aneurysm, this review summarizes the available treatment options (ie, parallel grafts, physician-modified endografts, in situ fenestrations, and OTS multibranched devices), compares the indications and contraindications, and points out the evidence gaps that should be filled in the next decade
    • 

    corecore