9,490 research outputs found

    A NICMOS Direct Imaging Search for Giant Planets around the Single White Dwarfs in the Hyades

    Full text link
    We report preliminary results from our search for massive giant planets (6-12 Jupiter masses) around the known seven single white dwarfs in the Hyades cluster at sub-arcsec separations. At an age of 625 Myr, the white dwarfs had progenitor masses of about 3 solar masses, and massive gaseous giant planets should have formed in the massive circumstellar disks around these ex-Herbig A0 stars, probably at orbital separations similar or slightly larger than that of Jupiter. Such planets would have survived the post-Main-Sequence mass loss of the parent star and would have migrated outward adiabatically to a distance of about 25 AU. At the distance of the Hyades (45 pc) this corresponds to an angular separation of 0.5 arcsec. J and H magnitudes of these giants are in the range of 20.5-23.3 mag, which can be resolved with NICMOS. The achieved sensitivities and contrast ratios agree well with simulations. Preliminary evaluation of the NICMOS data set did not reveal any evidence for neither planetary mass companions with masses down to about 10 Jupiter masses nor brown dwarfs around any of the seven white dwarfs for separations larger than 0.5 arcsec.Comment: 14th European Workshop on White Dwarf

    A transverse loading technique to enhance the pressure measurement capability of fibre Bragg gratings

    Get PDF
    A fibre optic pressure sensor based on the application of a transverse load onto an epoxy-resin material embedded over a sub-section of a fibre Bragg grating (FBG) is presented. When a transverse load is applied to the epoxy material it deforms and transfers the load onto the optical fibre in the form of an axial strain that changes the period of the FBG over the embedded region. This introduces a phase shift between the two resulting identical gratings that lie either side of the loaded section, creating a spectral drop-out within the bandwidth of the FBG. A 2 mm section at the centre of FBGs of length 6 mm, recorded in both single mode and highly linearly birefringent optical fibres, was embedded in resin, and were subsequently subjected to a transverse load. The loading technique, while offering protection to the optical fibre from mechanical damage, enhances transverse load sensitivity, without introducing birefringence

    Kinematics nomenclature for physiological accelerations with special reference to vestibular applications

    Get PDF
    Kinematics nomenclature for physiological accelerations and special reference to vestibular apparatu

    Interrogation of fibre Bragg gratings through a fibre optic rotary joint on a geotechnical centrifuge

    Get PDF
    The monitoring of an array of fibre Bragg gratings (FBGs) strain sensors was performed through a single channel, single mode fibre optic rotary joint (FORJ) mounted on a geotechnical centrifuge. The array of three FBGs was attached to an aluminum plate that was anchored at the ends and placed on the model platform of the centrifuge. Acceleration forces of up to 50g were applied and the reflection signal of the monitored FBGs recorded dynamically using a 2.5kHz FBG interrogator placed outside the centrifuge. The use of a FORJ allowed the monitoring of the FBGs without submitting the FBG interrogator to the high g-forces experienced in the centrifuge. © (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only

    Elicitation of horizontal nystagmus by periodic linear acceleration

    Get PDF
    Horizontal nystagmus elicitation in man by periodic linear acceleratio

    Energy barrier distributions for magnetic nanoparticles with competing cubic and uniaxial anisotropies

    Get PDF
    AbstractWe report in this study the effect of the competition between cubic and uniaxial anisotropies on the magnetic properties of magnetic nanoparticles. We have employed Monte Carlo simulations in our calculations and we have seen that the observed behavior is very different for the cases where easy uniaxial axes are completely random oriented or parallel to an external magnetic field. We have also calculated the effective energy barrier distribution probed during the isothermal magnetic relaxation and a two peak structure is observed only for a random orientation of uniaxial axes

    Monitoring techniques for the manufacture of tapered optical fibers

    Get PDF
    The use of a range of optical techniques to monitor the process of fabricating optical fiber tapers is investigated. Thermal imaging was used to optimize the alignment of the optical system; the transmission spectrum of the fiber was monitored to confirm that the tapers had the required optical properties and the strain induced in the fiber during tapering was monitored using in-line optical fiber Bragg gratings. Tapers were fabricated with diameters down to 5 ÎĽm and with waist lengths of 20 mm using single-mode SMF-28 fiber

    Range-resolved signal processing for fibre segment interferometry applied to dynamic long-gauge length strain sensing

    Get PDF
    A range-resolved interferometric signal processing technique using sinusoidal optical frequency modulation is applied to fibre segment interferometry. Here, six optical fibre segments of gauge length 12.5 cm are used as interferometric strain sensors and are formed between seven weak, broadband fibre Bragg gratings, acting as in-fibre partial reflectors. In a very simple and cost-effective optical setup using injection current modulation of a laser diode source, interferometric measurement of acoustic wave propagation in a metal rod is used to demonstrate the capabilities of the technique

    How to break access control in a controlled manner

    Get PDF
    The Electronic Medical Record (EMR) integrates heterogeneous information within a Healthcare Institution stressing the need for security and access control. The Biostatistics and Medical Informatics Department from Porto Faculty of Medicine has recently implemented a Virtual EMR (VEMR) in order to integrate patient information and clinical reports within a university hospital. With more than 500 medical doctors using the system on a daily basis, an access control policy and model were implemented. However, the healthcare environment has unanticipated situations (i.e. emergency situations) where access to information is essential. Most traditional policies do not allow for overriding. A policy that allows for Break-The-Glass (BTG) was implemented in order to override access control whilst providing for non-repudiation mechanisms for its usage. The policy was easily integrated within the model confirming its modularity and the fact that user intervention in defining security procedures is crucial to its successful implementation and use

    Using magnetic nanoparticles to probe protein damage in ferritin caused by freeze concentration

    Get PDF
    We demonstrate a method for monitoring the damage caused to a protein during freeze-thawing in the presence of glycerol, a cryo-protectant. For this work we synthesized magnetite nanoparticles doped with 2.5% cobalt inside the protein ferritin (CMF), dissolved them in different concentration glycerol solutions and measured their magnetization after freezing in a high applied field (5 T). As the temperature was raised, a step-like decrease in the sample magnetization was observed, corresponding to the onset of Brownian relaxation as the viscosity of the freeze-concentrated glycerol solution decreased. The position of the step reveals changes to the protein hydrodynamic radius that we attribute to protein unfolding, while its height depends on how much protein is trapped by ice during freeze concentration. Changes to the protein hydrodynamic radius are confirmed by dynamic light scattering (DLS) measurements, but unlike DLS, the magnetic measurements can provide hydrodynamic data while the solution remains mainly frozen
    • …
    corecore