131 research outputs found

    Cardiac output measurement in children: comparison of AesculonĀ® cardiac output monitor and thermodilution

    Get PDF
    Background We compared cardiac output (CO) measurements by the non-invasive electrical velocimetry (AesculonĀ®) monitor with the pulmonary artery catheter (PAC) thermodilution method in children. Methods CO values using the AesculonĀ® monitor and PAC thermodilution were simultaneously recorded during cardiac catheterization in children. Measurements were performed under general anaesthesia. To compare, three consecutive measurements for each patient within 3 min were obtained. The means of the three values were compared using simple regression and Bland-Altman analysis. Data were presented as mean (sd). A mean percentage of <30% was defined to indicate clinical useful reliability of the AesculonĀ® monitor. Results A total of 50 patients with a median (range) age of 7.5 (0.5-16.5) yr were enrolled in the study. Mean CO values were 3.7 (1.5) litre mināˆ’1 (PAC thermodilution) and 3.1 (1.7) litre mināˆ’1 (AesculonĀ® monitor). Analysis for CO measurement showed a good correlation between the two methods (r=0.894; P<0.0001). The bias between the two methods was 0.66 litre mināˆ’1 with a precision of 1.49 litre mināˆ’1. The mean percentage error for CO measurements was 48.9% for the AesculonĀ® monitor when compared with PAC thermodilution. Conclusions Electrical velocimetry using the AesculonĀ® monitor did not provide reliable CO values when compared with PAC thermodilution. Whether the AesculonĀ® monitor can be used as a CO trend monitor has to be assessed by further investigations in patients with changing haemodynamic

    Effects of autologous bone marrow stem cell transplantation on beta-adrenoceptor density and electrical activation pattern in a rabbit model of non-ischemic heart failure

    Get PDF
    BACKGROUND: Since only little is known on stem cell therapy in non-ischemic heart failure we wanted to know whether a long-term improvement of cardiac function in non-ischemic heart failure can be achieved by stem cell transplantation. METHODS: White male New Zealand rabbits were treated with doxorubicine (3 mg/kg/week; 6 weeks) to induce dilative non-ischemic cardiomyopathy. Thereafter, we obtained autologous bone marrow stem cells (BMSC) and injected 1.5ā€“2.0 Mio cells in 1 ml medium by infiltrating the myocardium via a left anterolateral thoracotomy in comparison to sham-operated rabbits. 4 weeks later intracardiac contractility was determined in-vivo using a Millar catheter. Thereafter, the heart was excised and processed for radioligand binding assays to detect Ī²(1)- and Ī²(2)-adrenoceptor density. In addition, catecholamine plasma levels were determined via HPLC. In a subgroup we investigated cardiac electrophysiology by use of 256 channel mapping. RESULTS: In doxorubicine-treated animals Ī²-adrenoceptor density was significantly down-regulated in left ventricle and septum, but not in right ventricle, thereby indicating a typical left ventricular heart failure. Sham-operated rabbits exhibited the same down-regulation. In contrast, BMSC transplantation led to significantly less Ī²-adrenoceptor down-regulation in septum and left ventricle. Cardiac contractility was significantly decreased in heart failure and sham-operated rabbits, but was significantly higher in BMSC-transplanted hearts. Norepinephrine and epinephrine plasma levels were enhanced in heart failure and sham-operated animals, while these were not different from normal in BMSC-transplanted animals. Electrophysiological mapping revealed unaltered electrophysiology and did not show signs of arrhythmogeneity. CONCLUSION: BMSC transplantation improves sympathoadrenal dysregualtion in non-ischemic heart failure

    The phenomenology of the mathematics classroom

    Get PDF
    This paper describes the mathematics classroom from the perspective of social phenomenology. Here the classroom is seen as an environment of signs, comprising things and people, which impinge on the reality of the individual child. The paper introduces a framework through which mathematical work is seen as taking place in the imagined world through the filter of the world in immediate perception. This provides an approach to structuring evolving mathematical understanding. It is suggested that mathematical ideas are contained and shaped by the child's personal phenomenology, which evolves through time. Further, I argue these ideas are never encountered directly but rather are met through a circular hermeneutic process of reconciling expectation with experience. Ā© 1996 Kluwer Academic Publishers

    Die Bewegungsgesetze des Raumkompasses

    No full text

    BĆ¼cherschau

    No full text

    Chronic left ventricular pacing preserves left ventricular function in children

    Full text link
    Chronic right ventricular (RV) pacing can induce structural and functional cardiac deterioration. Because animal studies showed a benefit of left ventricular (LV) over RV pacing, this study compared the effects of chronic RV and LV pacing in children. Retrospectively, echocardiographic data were evaluated from 18 healthy children (control subjects) and from children undergoing chronic epicardial RV pacing (7 RVP) or LV pacing (7 LVP). Assessment included LV end-diastolic wall thickness (LVEDWT) and end-systolic wall thickness (LVESWT) as well as LV end-diastolic diameter (LVEDD) and end-systolic diameter (LVESD). The shortening fraction and eccentricity index (LV diameter/2xLV wall thickness) were calculated as measures of LV function and eccentricity, respectively. Duration of QRS and septal posterior wall motion delay (SPWMD) were used as measures of electrical and mechanical dyssynchrony, respectively. A p value less than 0.05 determined significance. As the findings showed, LVEDD, LVESD, LVEDWT, and LVESWT were not significantly different between the groups. The shortening fraction was significantly lower in the RVP (21.7%+/-6.0%) than in the LVP (32.2%+/-5.2%) or control (29.3%+/-4.3%) children. The systolic LV eccentricity index was significantly larger in the RVP (1.8+/-0.2) than in the LVP (1.4+/-0.1) or control (1.4+/-0.2) children. The SPWMD was significantly larger in the RVP (338+/-20 ms) than in the LVP (-16+/-14 ms) or control (-5+/-35 ms) group, whereas QRS duration was similarly longer in the RVP (157+/-10 ms) and LVP (158+/-22 ms) groups compared than in the control group (69+/-7 ms). The authors conclude that LV function in children is preserved by chronic pacing at the LV lateral wall
    • ā€¦
    corecore