75 research outputs found

    Evaluation of semiautomated internal carotid artery stenosis quantification from 3-dimensional contrast-enhanced magnetic resonance angiograms

    Get PDF
    Rationale and Objectives: The performance of a semiautomatic technique for internal carotid artery (ICA) stenosis quantification of the internal carotid artery in contrast-enhanced magnetic resonance angiography was evaluated. Materials and Methods: The degree of stenosis of 52 ICAs was quantified by measuring the cross-sectional area along the center lumen line. This was performed both by 3 independent observers and the semiautomated method. The degree of stenosis was defined as the amount of cross-sectional lumen reduction. Results: Agreement between the method and observers was good (weighted-kappa, kappa(w) = 0.89). Reproducibility of measurements of the semiautomated technique was better (kappa(w) = 0.97) than that of the observers (kappa(w) = 0.76), and the evaluated technique was considerably less time-consuming. Conclusions: Because the user interaction is limited, this technique can be used to replace an expert observer in 3-dimensional stenosis quantification of the ICA at CE-MRA in clinical practice

    Clinical Outcome of Intra-Arterial Embolization for Treatment of Patients with Pelvic Trauma

    Get PDF
    Purpose. To analyse the technical success of pelvic embolization in our institution and to assess periprocedural hemodynamic status and morbidity/mortality of all pelvic trauma patients who underwent pelvic embolization. Methods. A retrospective analysis of patients with a pelvic fracture due to trauma who underwent arterial embolization was performed. Clinical data, pelvic radiographs, contrast-enhanced CT-scans, and angiographic findings were reviewed. Subsequently, the technical success and peri-procedural hemodynamic status were evaluated and described. Results. 19 trauma patients with fractures of the pelvis underwent arterial embolization. Initially, 10/19 patients (53%) were hemodynamically unstable prior to embolization. Technical success of embolization was 100%. 14/19 patients (74%) were stable after embolization, and treatment success was high as 74%. Conclusion. Angiography with subsequent embolization should be performed in patients with a pelvic fracture due to trauma and hemodynamic instability, after surgical intervention or with a persistent arterial blush indicative of an active bleeding on CT

    A new technique for precisely and accurately measuring lumbar spine bone mineral density in mice using clinical dual energy X-ray absorptiometry (DXA)

    Get PDF
    Dual Energy X-ray Absorptiometry (DXA) is effective in measuring bone mineral density (BMD) in mice for early detection of osteoporosis. However, scanners designed for use with small animals (i.e. PIXImus) are very expensive. Used human DXA machines are cheaper to obtain, but analysis of scans from these instruments is operator-dependent. Obtaining reliable data depends on having a single operator analyze the scans in a blinded fashion. Scan quality is improved by excising the bone prior to scanning, which does not allow serial measurements. This study describes a novel method of analyzing lumbar spine BMD in mice using whole body DXA. This non-invasive technique has a high degree of precision and reproducibility, with good correlation between multiple observers. Inter-observer variability (0.063 ± 0.00317 g/cm2 [mean ± SD], 5.05 [% coefficient of variation (CV)], repeat scan variability (0.063 ± 0.00364 g/cm2 [mean ± SD], 5.94 [%CV]) were very low compared to variability between different animals (0.063 ± 0.00588 g/cm2 [mean ± SD], 9.64 [%CV]) and variability seen in same animal over time (0.011 ± 0.00885 g/cm2 [mean ± SD], 80.68 [%CV]). The measurement error is thus smaller than the biological variation. Accuracy was determined by comparing average peak BMD from two scans per mouse in-vivo (0.066 g/cm2) versus excised spine (0.065 g/cm2). Furthermore, correlation between bone ash weights and whole body lumbar spine BMD measurements (p < 0.0001) was highly significant. This technique thus shows a high degree of precision and accuracy, even with multiple observers, for measuring BMD in mice using a DXA machine designed for clinical use

    Image quality assessment of the right ventricle with three different delayed enhancement sequences in patients suspected of ARVC/D

    Get PDF
    Histopathologic findings in arrhythmogenic right ventricular cardiomyopathy/dysplasia (ARVC/D) are replacement of the normal myocardium with fatty and fibrous elements with preferential involvement of the right ventricle. The right ventricular fibrosis can be visualised by post-gadolinium delayed enhancement inversion recovery imaging (DE imaging). We compared the image quality of three different gradient echo MRI sequences for short axis DE imaging of the right ventricle (RV). We retrospectively analysed MRI scans performed between February 2005 and December 2008 in 97 patients (mean age: 41.2 years, 67% men) suspected of ARVC/D. For DE imaging either a 2D Phase Sensitive (PSIR), a 2D (2D) or a 3D (3D) inversion recovery sequence was used in respectively 38, 32 and 27 MRI-examinations. The RV, divided in 10 segments, was assessed for image quality by two radiologists in random sequence. A consensus reading was performed if results differed between the two readings. Image quality was good in 24% of all segments in the 3D group, 66% in the 2D group and 79% in the PSIR group. Poor image quality was observed in 51% (3D), 10% (2D), and 2% (PSIR) of all segments. Exams were considered suitable for clinical use in 7% of exams in the 3D group, 75% of exams in the 2D group and 90% of exams of the PSIR group. Breathing-artifacts occurred in 22% (3D), 59% (2D) and 53% (PSIR). Motion-artifacts occurred in 56% (3D), 28% (2D) and 29% (PSIR). Post-gadolinium imaging using the PSIR sequence results in better and more consistent image quality of the RV compared to the 2D and 3D sequences

    Status Update and Interim Results from the Asymptomatic Carotid Surgery Trial-2 (ACST-2)

    Get PDF
    Objectives: ACST-2 is currently the largest trial ever conducted to compare carotid artery stenting (CAS) with carotid endarterectomy (CEA) in patients with severe asymptomatic carotid stenosis requiring revascularization. Methods: Patients are entered into ACST-2 when revascularization is felt to be clearly indicated, when CEA and CAS are both possible, but where there is substantial uncertainty as to which is most appropriate. Trial surgeons and interventionalists are expected to use their usual techniques and CE-approved devices. We report baseline characteristics and blinded combined interim results for 30-day mortality and major morbidity for 986 patients in the ongoing trial up to September 2012. Results: A total of 986 patients (687 men, 299 women), mean age 68.7 years (SD ± 8.1) were randomized equally to CEA or CAS. Most (96%) had ipsilateral stenosis of 70-99% (median 80%) with contralateral stenoses of 50-99% in 30% and contralateral occlusion in 8%. Patients were on appropriate medical treatment. For 691 patients undergoing intervention with at least 1-month follow-up and Rankin scoring at 6 months for any stroke, the overall serious cardiovascular event rate of periprocedural (within 30 days) disabling stroke, fatal myocardial infarction, and death at 30 days was 1.0%. Conclusions: Early ACST-2 results suggest contemporary carotid intervention for asymptomatic stenosis has a low risk of serious morbidity and mortality, on par with other recent trials. The trial continues to recruit, to monitor periprocedural events and all types of stroke, aiming to randomize up to 5,000 patients to determine any differential outcomes between interventions. Clinical trial: ISRCTN21144362. © 2013 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved

    Second asymptomatic carotid surgery trial (ACST-2): a randomised comparison of carotid artery stenting versus carotid endarterectomy

    Get PDF
    Background: Among asymptomatic patients with severe carotid artery stenosis but no recent stroke or transient cerebral ischaemia, either carotid artery stenting (CAS) or carotid endarterectomy (CEA) can restore patency and reduce long-term stroke risks. However, from recent national registry data, each option causes about 1% procedural risk of disabling stroke or death. Comparison of their long-term protective effects requires large-scale randomised evidence. Methods: ACST-2 is an international multicentre randomised trial of CAS versus CEA among asymptomatic patients with severe stenosis thought to require intervention, interpreted with all other relevant trials. Patients were eligible if they had severe unilateral or bilateral carotid artery stenosis and both doctor and patient agreed that a carotid procedure should be undertaken, but they were substantially uncertain which one to choose. Patients were randomly allocated to CAS or CEA and followed up at 1 month and then annually, for a mean 5 years. Procedural events were those within 30 days of the intervention. Intention-to-treat analyses are provided. Analyses including procedural hazards use tabular methods. Analyses and meta-analyses of non-procedural strokes use Kaplan-Meier and log-rank methods. The trial is registered with the ISRCTN registry, ISRCTN21144362. Findings: Between Jan 15, 2008, and Dec 31, 2020, 3625 patients in 130 centres were randomly allocated, 1811 to CAS and 1814 to CEA, with good compliance, good medical therapy and a mean 5 years of follow-up. Overall, 1% had disabling stroke or death procedurally (15 allocated to CAS and 18 to CEA) and 2% had non-disabling procedural stroke (48 allocated to CAS and 29 to CEA). Kaplan-Meier estimates of 5-year non-procedural stroke were 2·5% in each group for fatal or disabling stroke, and 5·3% with CAS versus 4·5% with CEA for any stroke (rate ratio [RR] 1·16, 95% CI 0·86–1·57; p=0·33). Combining RRs for any non-procedural stroke in all CAS versus CEA trials, the RR was similar in symptomatic and asymptomatic patients (overall RR 1·11, 95% CI 0·91–1·32; p=0·21). Interpretation: Serious complications are similarly uncommon after competent CAS and CEA, and the long-term effects of these two carotid artery procedures on fatal or disabling stroke are comparable. Funding: UK Medical Research Council and Health Technology Assessment Programme

    Nintedanib for Systemic Sclerosis-Associated Interstitial Lung Disease

    Get PDF
    BACKGROUND: Interstitial lung disease (ILD) is a common manifestation of systemic sclerosis and a leading cause of systemic sclerosis-related death. Nintedanib, a tyrosine kinase inhibitor, has been shown to have antifibrotic and antiinflammatory effects in preclinical models of systemic sclerosis and ILD. METHODS: We conducted a randomized, double-blind, placebo-controlled trial to investigate the efficacy and safety of nintedanib in patients with ILD associated with systemic sclerosis. Patients who had systemic sclerosis with an onset of the first non-Raynaud's symptom within the past 7 years and a high-resolution computed tomographic scan that showed fibrosis affecting at least 10% of the lungs were randomly assigned, in a 1:1 ratio, to receive 150 mg of nintedanib, administered orally twice daily, or placebo. The primary end point was the annual rate of decline in forced vital capacity (FVC), assessed over a 52-week period. Key secondary end points were absolute changes from baseline in the modified Rodnan skin score and in the total score on the St. George's Respiratory Questionnaire (SGRQ) at week 52. RESULTS: A total of 576 patients received at least one dose of nintedanib or placebo; 51.9% had diffuse cutaneous systemic sclerosis, and 48.4% were receiving mycophenolate at baseline. In the primary end-point analysis, the adjusted annual rate of change in FVC was 1252.4 ml per year in the nintedanib group and 1293.3 ml per year in the placebo group (difference, 41.0 ml per year; 95% confidence interval [CI], 2.9 to 79.0; P=0.04). Sensitivity analyses based on multiple imputation for missing data yielded P values for the primary end point ranging from 0.06 to 0.10. The change from baseline in the modified Rodnan skin score and the total score on the SGRQ at week 52 did not differ significantly between the trial groups, with differences of 120.21 (95% CI, 120.94 to 0.53; P=0.58) and 1.69 (95% CI, 120.73 to 4.12 [not adjusted for multiple comparisons]), respectively. Diarrhea, the most common adverse event, was reported in 75.7% of the patients in the nintedanib group and in 31.6% of those in the placebo group. CONCLUSIONS: Among patients with ILD associated with systemic sclerosis, the annual rate of decline in FVC was lower with nintedanib than with placebo; no clinical benefit of nintedanib was observed for other manifestations of systemic sclerosis. The adverse-event profile of nintedanib observed in this trial was similar to that observed in patients with idiopathic pulmonary fibrosis; gastrointestinal adverse events, including diarrhea, were more common with nintedanib than with placebo
    corecore