8 research outputs found

    Phacoemulsification Wound Burn and Its Management

    Get PDF
    Introduction: The production of ultrasonic energy during phacoemulsification is associated with heat generation that could damage ocular tissues, particularly at the corneoscleral wound site. Case presentation: This study presents an 89-year-old patient with senile hypermature cataract and Fuchs endothelial dystrophy developing severe thermal corneoscleral injury during phacoemulsification. At presentation, visual acuity was finger count at 40 cm and there was a 1 × 2-mm area of corneal melting at the corneal tunnel with diffuse corneal oedema. After 1 month, a temporal circular corneal patch graft was applied to the corneal burn. A penetrating keratoplasty was performed 16 months after the first surgery. Conclusion: Corneal surgery, including lamellar patch grafts and full-thickness penetrating grafts, could be used, when necessary, to restore the cornea's integrity. These procedures could eliminate corneal scarring, decrease astigmatism, and improve vision in patients with phacoemulsification burns

    Hitting the refractive target in corneal endothelial transplantation triple procedures: A systematic review

    Get PDF
    In phakic patients Descemet stripping automated endothelial keratoplasty (DSAEK) or Descemet membrane endothelial keratoplasty (DMEK) are frequently combined with phacoemulsification and intraocular lens (IOL) implantation (triple procedure). This surgery might cause a refractive shift difficult to predict. Early DMEK and DSAEK results have shown a tendency toward a hyperopic shift. Myopic postoperative refraction is typically intended to correct this postoperative refractive defect and to bring all eyes as close to emmetropia as possible. We sought to understand the mechanism underlying the hyperopization and to identify predictive factors for poorer refractive outcomes, the most suitable target refraction and IOL calculation methods in patients undergoing combined cataract extraction and lamellar endothelial corneal transplantation (DSAEK or DMEK) for endothelial dysfunctions. Of the 407 articles analyzed, only 18 were included in the analysis. A myopic target between -0.50 D and -0.75 was the most common (up to -1.50 for DSAEK triple procedures), even though no optimum target was found. Hyperopic surprises appeared more frequently in corneas that were flatter in the center than in the periphery (oblate posterior profile). Among the numerous IOL calculation formulas, there was no apparent preference

    Visual outcomes and patient satisfaction after bilateral implantation of an enhanced monofocal intraocular lens: a single-masked prospective randomized study

    Get PDF
    Purpose: To evaluate and compare the visual outcomes of an enhanced monofocal intraocular lens (IOL) with two different monofocal IOLs. Setting: Eye Clinic, Department of Medicine, Surgery and Health Sciences, University of Trieste, Trieste, Italy. Design: Prospective, single-center, single-masked, randomized controlled clinical study. Methods: The study included patients undergoing phacoemulsification and IOL implantation. Patients were consecutively randomized by block randomization and assigned in a 1:1:1 allocation ratio to three study arms to bilaterally receive Tecnis EyhanceTM (model ICB00) or TecnisÂź monofocal 1-piece (model PCB00) or ClareonÂź monofocal (model CNA0T0), respectively. Monocular and binocular (both corrected and uncorrected) visual acuities for far, intermediate and near were registered and compared among groups at 3 months. To track changes in patient quality of life, the Catquest-9SF questionnaire was administered to each patient before and after cataract extraction. Results: Ninety patients (30 for each group) were enrolled. At 3 months follow-up, statistically significant differences for intermediate visual acuities were found between the three groups. Nonstatistically significant differences were observed for distance visual acuities and the changes in Catquest-9SF scores. Conclusion: Tecnis EyhanceTM provided better results in intermediate visual outcomes without adverse effects on patients' quality of life

    Artificial intelligence applications and cataract management: A systematic review

    Get PDF
    Artificial intelligence (AI)-based applications exhibit the potential to improve the quality and efficiency of patient care in different fields, including cataract management. A systematic review of the different applications of AI-based software on all aspects of a cataract patient's management, from diagnosis to follow-up, was carried out in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. All selected articles were analyzed to assess the level of evidence according to the Oxford Centre for Evidence-Based Medicine 2011 guidelines, and the quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation system. Of the articles analyzed, 49 met the inclusion criteria. No data synthesis was possible for the heterogeneity of available data and the design of the available studies. The AI-driven diagnosis seemed to be comparable and, in selected cases, to even exceed the accuracy of experienced clinicians in classifying disease, supporting the operating room scheduling, and intraoperative and postoperative management of complications. Considering the heterogeneity of data analyzed, however, further randomized controlled trials to assess the efficacy and safety of AI application in the management of cataract should be highly warranted

    Changes in Anterior Segment Morphology and Intraocular Pressure after Cataract Surgery in Non-glaucomatous Eyes

    No full text
    Background It is known that cataract extraction is associated with a significant reduction in intraocular pressure, especially in narrow angled eyes; however, the modifications of anterior segment parameters associated with this phenomenon have still not been completely defined. The purpose of this study was to evaluate changes in anterior segment anatomy and intraocular pressure after cataract surgery in non-glaucomatous eyes.Methods and Material This retrospective case series study included 64 eyes of 64 consecutive patients who underwent phacoemulsification with intraocular lens implantation. Anterior segment parameters and intraocular pressure were assessed and compared before and 6 months after surgery. Anterior segment imaging was performed using Casia SS-1000 anterior segment optical coherence tomography (Tomey, Nagoya, Japan). Anterior segment measurements included anterior chamber depth, anterior chamber width, anterior chamber volume, angle opening distance at 500 mu m anterior to the scleral spur, angle recess area 750 mu m from the scleral spur, lens vault, trabecular iris space area at 500 mu m from the scleral spur, and trabecular iris angle at 500 mu m from the scleral spur. Intraocular pressure was measured using the Goldmann applanation tonometer (Model AT 900 C/M, Haag-Streit, Bern, Switzerland). Anterior segment parameters and the relationship of changes in intraocular pressure were also evaluated.Results All anterior segment parameters increased significantly after surgery (p < 0.05). Both angle opening distance at 500 mu m anterior to the scleral spur and anterior chamber depth changes were positively correlated with the preoperative lens vault. The mean intraocular pressure significantly decreased from 14.91mmHg (+/- 2.8 SD) to 12.91mmHg (+/- 3.13 SD) (p < 0.001). Changes in intraocular pressure correlated negatively with values for the width of the preoperative anterior chamber (r = - 0.533; p = 0.001).Conclusion Cataract surgery led to significant widening of the anterior chamber angle and lowering of intraocular pressure. Further investigations are needed to better understand whether anterior chamber width may be a new independent predictive factor for reduction in postoperative intraocular pressure

    First narrow-band search for continuous gravitational waves from known pulsars in advanced detector data

    No full text
    International audienceSpinning neutron stars asymmetric with respect to their rotation axis are potential sources of continuous gravitational waves for ground-based interferometric detectors. In the case of known pulsars a fully coherent search, based on matched filtering, which uses the position and rotational parameters obtained from electromagnetic observations, can be carried out. Matched filtering maximizes the signal-to-noise (SNR) ratio, but a large sensitivity loss is expected in case of even a very small mismatch between the assumed and the true signal parameters. For this reason, narrow-band analysis methods have been developed, allowing a fully coherent search for gravitational waves from known pulsars over a fraction of a hertz and several spin-down values. In this paper we describe a narrow-band search of 11 pulsars using data from Advanced LIGO’s first observing run. Although we have found several initial outliers, further studies show no significant evidence for the presence of a gravitational wave signal. Finally, we have placed upper limits on the signal strain amplitude lower than the spin-down limit for 5 of the 11 targets over the bands searched; in the case of J1813-1749 the spin-down limit has been beaten for the first time. For an additional 3 targets, the median upper limit across the search bands is below the spin-down limit. This is the most sensitive narrow-band search for continuous gravitational waves carried out so far

    First low-frequency Einstein@Home all-sky search for continuous gravitational waves in Advanced LIGO data

    No full text
    International audienceWe report results of a deep all-sky search for periodic gravitational waves from isolated neutron stars in data from the first Advanced LIGO observing run. This search investigates the low frequency range of Advanced LIGO data, between 20 and 100 Hz, much of which was not explored in initial LIGO. The search was made possible by the computing power provided by the volunteers of the Einstein@Home project. We find no significant signal candidate and set the most stringent upper limits to date on the amplitude of gravitational wave signals from the target population, corresponding to a sensitivity depth of 48.7  [1/Hz]. At the frequency of best strain sensitivity, near 100 Hz, we set 90% confidence upper limits of 1.8×10-25. At the low end of our frequency range, 20 Hz, we achieve upper limits of 3.9×10-24. At 55 Hz we can exclude sources with ellipticities greater than 10-5 within 100 pc of Earth with fiducial value of the principal moment of inertia of 1038  kg m2

    Search for intermediate mass black hole binaries in the first observing run of Advanced LIGO

    No full text
    International audienceDuring their first observational run, the two Advanced LIGO detectors attained an unprecedented sensitivity, resulting in the first direct detections of gravitational-wave signals produced by stellar-mass binary black hole systems. This paper reports on an all-sky search for gravitational waves (GWs) from merging intermediate mass black hole binaries (IMBHBs). The combined results from two independent search techniques were used in this study: the first employs a matched-filter algorithm that uses a bank of filters covering the GW signal parameter space, while the second is a generic search for GW transients (bursts). No GWs from IMBHBs were detected; therefore, we constrain the rate of several classes of IMBHB mergers. The most stringent limit is obtained for black holes of individual mass 100  M⊙, with spins aligned with the binary orbital angular momentum. For such systems, the merger rate is constrained to be less than 0.93  Gpc−3 yr−1 in comoving units at the 90% confidence level, an improvement of nearly 2 orders of magnitude over previous upper limits