529 research outputs found

    Derivation of transient relativistic fluid dynamics from the Boltzmann equation

    Full text link
    In this work we present a general derivation of relativistic fluid dynamics from the Boltzmann equation using the method of moments. The main difference between our approach and the traditional 14-moment approximation is that we will not close the fluid-dynamical equations of motion by truncating the expansion of the distribution function. Instead, we keep all terms in the moment expansion. The reduction of the degrees of freedom is done by identifying the microscopic time scales of the Boltzmann equation and considering only the slowest ones. In addition, the equations of motion for the dissipative quantities are truncated according to a systematic power-counting scheme in Knudsen and inverse Reynolds number. We conclude that the equations of motion can be closed in terms of only 14 dynamical variables, as long as we only keep terms of second order in Knudsen and/or inverse Reynolds number. We show that, even though the equations of motion are closed in terms of these 14 fields, the transport coefficients carry information about all the moments of the distribution function. In this way, we can show that the particle-diffusion and shear-viscosity coefficients agree with the values given by the Chapman-Enskog expansion.Comment: 27 page

    Oxidation of cellulose in pressurized carbon dioxide

    Get PDF
    This work presents first results upon oxidation of type II cellulose by nitrogen dioxide dissolved in carbon dioxide at high pressure. This reaction leads to oxidized cellulose, a natural-based bioresorbable fabric used for biomedical applications. The oxidation reaction takes place in a heterogeneous fluid–solid system. Kinetics of oxidation is presented here and effects of operating conditions such as pressure, temperature and initial moisture content of cellulose are investigated. Results are presented in terms of degree of oxidation of cellulose and quality of the final oxidized cellulose, which has been characterized using liquid-state and solid-state 13C NMR. The experimental results show the existence of possible secondary reactions which may lead to oxidized cellulose with insufficient mechanical strength. An attempt is made to evidence and understand the role of CO2 as a solvent in this system. Indeed, although supercritical CO2 appears to be a suitable candidate as a solvent for oxidation reactions, some inhibiting effect on nitrogen dioxide activity are observed in this case

    Is the Shroud of Turin in Relation to the Old Jerusalem Historical Earthquake?

    Full text link
    Phillips and Hedges suggested, in the scientific magazine Nature (1989), that neutron radiation could be liable of a wrong radiocarbon dating, while proton radiation could be responsible of the Shroud body image formation. On the other hand, no plausible physical reason has been proposed so far to explain the radiation source origin, and its effects on the linen fibres. However, some recent studies, carried out by the first author and his Team at the Laboratory of Fracture Mechanics of the Politecnico di Torino, found that it is possible to generate neutron emissions from very brittle rock specimens in compression through piezonuclear fission reactions. Analogously, neutron flux increments, in correspondence to seismic activity, should be a result of the same reactions. A group of Russian scientists measured a neutron flux exceeding the background level by three orders of magnitude in correspondence to rather appreciable earthquakes (4th degree in Richter Scale). The authors consider the possibility that neutron emissions by earthquakes could have induced the image formation on Shroud linen fibres, trough thermal neutron capture by Nitrogen nuclei, and provided a wrong radiocarbon dating due to an increment in C(14,6)content. Let us consider that, although the calculated integral flux of 10^13 neutrons per square centimetre is 10 times greater than the cancer therapy dose, nevertheless it is100 times smaller than the lethal dose.Comment: 13 pages, 1 figur

    Assessment of the radioanatomic positioning of the osteoarthritic knee in serial radiographs: comparison of three acquisition techniques

    Get PDF
    SummaryObjectiveRecent studies using various standardized radiographic acquisition techniques have demonstrated the necessity of reproducible radioanatomic alignment of the knee to assure precise measurements of medial tibiofemoral joint space width (JSW). The objective of the present study was to characterize the longitudinal performance of several acquisition techniques with respect to long-term reproducibility of positioning of the knee, and the impact of changes in positioning on the rate and variability of joint space narrowing (JSN).MethodsEighty subjects were randomly selected from each of three cohorts followed in recent studies of the radiographic progression of knee osteoarthritis (OA): the Health ABC study (paired fixed-flexion [FF] radiographs taken at a 36-month interval); the Glucosamine Arthritis Intervention Trial (GAIT) (paired metatarsophalangeal [MTP] radiographs obtained at a 12-month interval), and a randomized clinical trial of doxycycline (fluoroscopically assisted semiflexed anteroposterior (AP) radiographs taken at a 16-month interval).Manual measurements were obtained from each radiograph to represent markers of radioanatomic positioning of the knee (alignment of the medial tibial plateau and X-ray beam, knee rotation, femorotibial angle) and to evaluate minimum JSW (mJSW) in the medial tibiofemoral compartment. The effects on the mean annualized rate of JSN and on the variability of that rate of highly reproduced vs variable positioning of the knee in serial radiographs were evaluated.ResultsParallel or near-parallel alignment was achieved significantly more frequently with the fluoroscopically guided positioning used in the semiflexed AP protocol than with either the non-fluoroscopic FF or MTP protocol (68% vs 14% for both FF and MTP protocols when measured at the midpoint of the medial compartment; 75% vs 26% and 34% for the FF and MTP protocols, respectively, when measured at the site of mJSW; P<0.001 for each). Knee rotation was reproduced more frequently in semiflexed AP radiographs than in FF radiographs (66% vs 45%, P<0.01). In contrast, the FF technique yielded a greater proportion of paired radiographs in which the femorotibial angle was accurately reproduced than the semiflexed AP or MTP protocol (78% vs 59% and 56%, respectively, P<0.01 for each). Notably, only paired radiographs with parallel or near-parallel alignment exhibited a mean rate of JSN (±SD) in the OA knee that was more rapid and less variable than that measured in all knees (0.186±0.274mm/year, standardized response to mean [SRM]=0.68 vs 0.128±0.291mm/year, SRM=0.44).ConclusionThis study confirms the importance of parallel radioanatomic alignment of the anterior and posterior margins of the medial tibial plateau in detecting JSN in subjects with knee OA. The use of radiographic methods that assure parallel alignment during serial X-ray examinations will permit the design of more efficient studies of biomarkers of OA progression and of structure modification in knee OA

    Circulating adrenomedullin estimates survival and reversibility of organ failure in sepsis: the prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock-1 (AdrenOSS-1) study

    Get PDF
    Background: Adrenomedullin (ADM) regulates vascular tone and endothelial permeability during sepsis. Levels of circulating biologically active ADM (bio-ADM) show an inverse relationship with blood pressure and a direct relationship with vasopressor requirement. In the present prospective observational multinational Adrenomedullin and Outcome in Sepsis and Septic Shock 1 (, AdrenOSS-1) study, we assessed relationships between circulating bio-ADM during the initial intensive care unit (ICU) stay and short-term outcome in order to eventually design a biomarker-guided randomized controlled trial. Methods: AdrenOSS-1 was a prospective observational multinational study. The primary outcome was 28-day mortality. Secondary outcomes included organ failure as defined by Sequential Organ Failure Assessment (SOFA) score, organ support with focus on vasopressor/inotropic use, and need for renal replacement therapy. AdrenOSS-1 included 583 patients admitted to the ICU with sepsis or septic shock. Results: Circulating bio-ADM levels were measured upon admission and at day 2. Median bio-ADM concentration upon admission was 80.5 pg/ml [IQR 41.5-148.1 pg/ml]. Initial SOFA score was 7 [IQR 5-10], and 28-day mortality was 22%. We found marked associations between bio-ADM upon admission and 28-day mortality (unadjusted standardized HR 2.3 [CI 1.9-2.9]; adjusted HR 1.6 [CI 1.1-2.5]) and between bio-ADM levels and SOFA score (p &lt; 0.0001). Need of vasopressor/inotrope, renal replacement therapy, and positive fluid balance were more prevalent in patients with a bio-ADM &gt; 70 pg/ml upon admission than in those with bio-ADM ≤ 70 pg/ml. In patients with bio-ADM &gt; 70 pg/ml upon admission, decrease in bio-ADM below 70 pg/ml at day 2 was associated with recovery of organ function at day 7 and better 28-day outcome (9.5% mortality). By contrast, persistently elevated bio-ADM at day 2 was associated with prolonged organ dysfunction and high 28-day mortality (38.1% mortality, HR 4.9, 95% CI 2.5-9.8). Conclusions: AdrenOSS-1 shows that early levels and rapid changes in bio-ADM estimate short-term outcome in sepsis and septic shock. These data are the backbone of the design of the biomarker-guided AdrenOSS-2 trial. Trial registration: ClinicalTrials.gov, NCT02393781. Registered on March 19, 2015

    Derivation of fluid dynamics from kinetic theory with the 14--moment approximation

    Full text link
    We review the traditional derivation of the fluid-dynamical equations from kinetic theory according to Israel and Stewart. We show that their procedure to close the fluid-dynamical equations of motion is not unique. Their approach contains two approximations, the first being the so-called 14-moment approximation to truncate the single-particle distribution function. The second consists in the choice of equations of motion for the dissipative currents. Israel and Stewart used the second moment of the Boltzmann equation, but this is not the only possible choice. In fact, there are infinitely many moments of the Boltzmann equation which can serve as equations of motion for the dissipative currents. All resulting equations of motion have the same form, but the transport coefficients are different in each case.Comment: 15 pages, 3 figures, typos fixed and discussions added; EPJA: Topical issue on "Relativistic Hydro- and Thermodynamics

    Echocardiography and assessing fluid responsiveness: acoustic quantification again into the picture?

    Get PDF
    Accurate identification of fluid responsiveness has become an important issue in critically ill patients. Pulse pressure and stroke volume variation have been shown to be reliable predictors of fluid responsiveness. Apart from these two valuable techniques, echo-Doppler offers an interesting alternative for estimating the adequacy of filling. Acoustic quantification is a high-tech tool for delineating the blood-tissue interface on-screen in real time. Cannesson and coworkers utilized this technique in ventilated patients to assess stroke area changes, with the intention being to predict fluid responsiveness

    Cardiac tamponade related to a coronary injury by a pericardial calcification: an unusual complication

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Cardiac tamponade is a rare but severe complication of pericardial effusion with a poor prognosis. Prompt diagnosis using transthoracic echocardiography allows guiding initial therapeutic management. Although etiologies are numerous, cardiac tamponade is more often due to a hemopericardium. Rarely, a coronary injury may result in such a hemopericardium with cardiac tamponade. Coronary artery aneurysm are the main etiologies but blunt, open chest trauma or complication of endovascular procedures have also been described.</p> <p>Case presentation</p> <p>A 83-year-old hypertensive man presented for dizziness and hypotension. The patient had oliguria and mottled skin. Transthoracic echocardiography disclosed a circumferential pericardial effusion with a compressed right atrium, confirmed by contrast-enhanced thoracic CT scan. A pig-tail catheter allowed to withdraw 500 mL of blood, resulting in a transient improvement of hemodynamics. Rapidly, recurrent hypotension prompted a reoperation. An active bleeding was identified at the level of the retroventricular coronary artery. The pericardium was thickened with several "sharping" calcified plaques in the vicinity of the bleeding areas. On day 2, vasopressors were stopped and the patient was successfully extubated. Final diagnosis was a spontaneous cardiac tamponade secondary to a coronary artery injury attributed to a "sharping"calcified pericardial plaque.</p> <p>Conclusion</p> <p>Cardiac tamponade secondary to the development of a hemopericardium may develop as the result of a myocardial and coronary artery injury induced by a calcified pericardial plaque.</p

    Consensus on circulatory shock and hemodynamic monitoring. Task force of the European Society of Intensive Care Medicine.

    Get PDF
    OBJECTIVE: Circulatory shock is a life-threatening syndrome resulting in multiorgan failure and a high mortality rate. The aim of this consensus is to provide support to the bedside clinician regarding the diagnosis, management and monitoring of shock. METHODS: The European Society of Intensive Care Medicine invited 12 experts to form a Task Force to update a previous consensus (Antonelli et al.: Intensive Care Med 33:575-590, 2007). The same five questions addressed in the earlier consensus were used as the outline for the literature search and review, with the aim of the Task Force to produce statements based on the available literature and evidence. These questions were: (1) What are the epidemiologic and pathophysiologic features of shock in the intensive care unit ? (2) Should we monitor preload and fluid responsiveness in shock ? (3) How and when should we monitor stroke volume or cardiac output in shock ? (4) What markers of the regional and microcirculation can be monitored, and how can cellular function be assessed in shock ? (5) What is the evidence for using hemodynamic monitoring to direct therapy in shock ? Four types of statements were used: definition, recommendation, best practice and statement of fact. RESULTS: Forty-four statements were made. The main new statements include: (1) statements on individualizing blood pressure targets; (2) statements on the assessment and prediction of fluid responsiveness; (3) statements on the use of echocardiography and hemodynamic monitoring. CONCLUSIONS: This consensus provides 44 statements that can be used at the bedside to diagnose, treat and monitor patients with shock

    Evaluation of the fineness of degummed bast fibers

    Full text link
    Fiber fineness characteristics are important for yarn production and quality. In this paper, degummed bast fibers such as hemp, flax and ramie have been examined with the Optical Fiber Diameter Analyzer (OFDA100 and OFDA2000) systems for fiber fineness, in comparison with the conventional image analysis and the Wira airflow tester. The correlation between the results from these measurements was analysed. The results indicate that there is a significant linear co-relation between the fiber fineness measurement results obtained from those different systems. In addition, the mean fiber width and its coefficient of variation obtained from the OFDA100 system are smaller than those obtained from the OFDA2000 system, due to the difference in sample preparation methods. The OFDA2000 system can also measure the fiber fineness profile along the bast fiber plants, which can be useful for plant breeding. <br /
    • …
    corecore