163 research outputs found

    Assessing Human Eye Exposure to UV Light: A Narrative Review.

    Get PDF
    Exposure to ultraviolet light is associated with several ocular pathologies. Understanding exposure levels and factors is therefore important from a medical and prevention perspective. A review of the current literature on ocular exposure to ultraviolet light is conducted in this study. It has been shown that ambient irradiance is not a good indicator of effective exposure and current tools for estimating dermal exposure have limitations for the ocular region. To address this, three methods have been developed: the use of anthropomorphic manikins, measurements through wearable sensors and numerical simulations. The specific objective, limitations, and results obtained for the three different methods are discussed

    Influence of experimental parameters on in vitro human skin permeation of Bisphenol A.

    Get PDF
    Bisphenol A (BPA) in vitro skin permeation studies have shown inconsistent results, which could be due to experimental conditions. We studied the impact of in vitro parameters on BPA skin permeation using flow-through diffusion cells with ex-vivo human skin (12 donors, 3-12 replicates). We varied skin status (viable or frozen skin) and thickness (200, 400, 800 μm), BPA concentrations (18, 250 mg/l) and vehicle volumes (10, 100 and 1000 μl/cm <sup>2</sup> ). These conditions led to a wide range of BPA absorption (2%-24% after 24 h exposure), peak permeation rates (J = 0.02-1.31 μg/cm <sup>2</sup> /h), and permeability coefficients (K <sub>p</sub> = 1.6-5.2 × 10 <sup>-3</sup> cm/h). This is the first time steady state conditions were reached for BPA aqueous solutions in vitro (1000 μl/cm <sup>2</sup> applied at concentration 250 mg/l). A reduction of the skin thickness from 800 and 400 μm to 200 μm led to a 3-fold increase of J (P < 0.05). A reduction of the vehicle volume from 1000 to 100 led to a 2-fold decrease in J (P > 0.05). Previously frozen skin led to a 3-fold increase in J compared to viable skin (P < 0.001). We found that results from published studies were consistent when adjusting J according to experimental parameters. We propose appropriate J values for different exposure scenarios to calculate BPA internal exposures for use in risk assessment

    Marqueurs atmosphériques d'exposition aux particules Diesel

    Get PDF
    L'évolution du parc français d'automobiles particulières a pris depuis une vingtaine d'années un essor formidable. De près de 12 millions de voitures en 1970, il est passé à 23,5 millions en 1991, soit un doublement. Une telle augmentation entraîne bien évidemment un accroissement de la pollution atmosphérique d'origine automobile et a conduit la Communauté Européenne à réglementer les émissions dès 1970. La pollution automobile était alors traitée comme un problème global, tous types de véhicules confondus. Depuis, deux événements sont venus modifier les règle

    Exposure to Amosite-Containing Ceiling Boards in a Public School in Switzerland: A Case Study.

    Get PDF
    The measurement of an airborne concentration in Amosite fibers above 5035 F/m <sup>3</sup> in a school prompted a retrospective quantitative health risk assessment. Dose estimates were built using air measurements, laboratory experiments, previous exposure data, and interviews. A dose response model was adapted for amosite-only exposure and adjusted for the life expectancy and lung cancer incidence in the Swiss population. The average yearly concentrations found were 52-320 F/m <sup>3</sup> . The high concentration previously observed was not representative of the average exposure in the building. Overall, the risk estimates for the different populations of the school were low and in the range of 2 × 10 <sup>-6</sup> to 3 × 10 <sup>-5</sup> for mesothelioma and 4 × 10 <sup>-7</sup> to 8 × 10 <sup>-6</sup> for lung cancer. The results evidenced however that children have to be considered at higher risk when exposed to asbestos, and that the current reference method and target values are of limited use for amphibole-only exposures. This study confirmed that quantitative health risk assessments and participatory approaches are powerful tools to support public decisions and build constructive communication between exposed people, experts, and policy-makers

    Sun exposure to the eyes: predicted UV protection effectiveness of various sunglasses.

    Get PDF
    The aim of this study was to assess solar ultraviolet radiation (UVR) doses received by the eyes in different exposure situations, and to predict the sun protection effectiveness provided by various styles of sunglasses at facial, periorbital, and ocular skin zones including the cornea and accounting for different head positions. A 3D numeric model was optimized to predict direct, diffuse and reflected erythemally weighted UVR doses received at various skin zones. Precisely defined facial, periorbital, and ocular skin zones, sunglasses (goggles, medium-, and large-sized sunglasses) and three head positions were modeled to simulate daily (08:00-17:00) and midday (12:00-14:00) UVR doses. The shading from sunglasses' frame and lenses' UVR transmission were used to calculate a predictive protection factor (PPF [%]). Highest ocular daily UVR doses were estimated at the uncovered cornea (1718.4 J/m <sup>2</sup> ). Least sun protection was provided by middle-sized sunglasses with highest midday dose at the white lateral (290.8 J/m <sup>2</sup> ) and lateral periorbital zones (390.9 J/m <sup>2</sup> ). Goggles reached almost 100% protection at all skin zones. Large-sized sunglasses were highly effective in winter; however, their effectiveness depended on diffuse UVR doses received. In "looking-up" head positions highest midday UVR doses were received at the unprotected cornea (908.1 J/m <sup>2</sup> ), totally protected when large-sized sunglasses are used. All tested sunglass lenses fully blocked UVR. Sunglasses' protection effectiveness is strongly influenced by geometry, wearing position, head positions, and exposure conditions. Sunglasses do not totally block UVR and should be combined with additional protection means. 3D modeling allows estimating UVR exposure of highly sensitive small skin zones, chronically exposed and rarely assessed

    Evaluation of Exposure Assessment Tools under REACH: Part II-Higher Tier Tools.

    Get PDF
    Stoffenmanager®v4.5 and Advanced REACH Tool (ART) v1.5, two higher tier exposure assessment tools for use under REACH, were evaluated by determining accuracy and robustness. A total of 282 exposure measurements from 51 exposure situations (ESs) were collected and categorized by exposure category. In this study, only the results of liquids with vapor pressure (VP) > 10 Pa category having a sufficient number of exposure measurements (n = 251 with 42 ESs) were utilized. In addition, the results were presented by handling/activity description and input parameters for the same exposure category. It should be noted that the performance results of Stoffenmanager and ART in this study cannot be directly compared for some ESs because ART allows a combination of up to four subtasks (and nonexposed periods) to be included, whereas the database for Stoffenmanager, separately developed under the permission of the legal owner of Stoffenmanager, permits the use of only one task to predict exposure estimates. Thus, it would be most appropriate to compare full-shift measurements against ART predictions (full shift including nonexposed periods) and task-based measurements against task-based Stoffenmanager predictions. For liquids with VP > 10 Pa category, Stoffenmanager®v4.5 appeared to be reasonably accurate and robust when predicting exposures [percentage of measurements exceeding the tool's 90th percentile estimate (%M > T) was 15%]. Areas that could potentially be improved include ESs involving the task of handling of liquids on large surfaces or large work pieces, allocation of high and medium VP inputs, and absence of local exhaust ventilation input. Although the ART's median predictions appeared to be reasonably accurate for liquids with VP > 10 Pa, the %M > T for the 90th percentile estimates was 41%, indicating that variance in exposure levels is underestimated by ART. The %M > T using the estimates of the upper value of 90% confidence interval (CI) of the 90th percentile estimate (UCI90) was considerably reduced to 18% for liquids with VP > 10 Pa. On the basis of this observation, users might be to consider using the upper limit value of 90% CI of the 90th percentile estimate for predicting reasonable worst case situations. Nevertheless, for some activities and input parameters, ART still shows areas to be improved. Hence, it is suggested that ART developers review the assumptions in relation to exposure variability within the tool, toward improving the tool performance in estimating percentile exposure levels. In addition, for both tools, only some handling/activity descriptions and input parameters were considered. Thus, further validation studies are still necessary

    Evaluation of Exposure Assessment Tools under REACH: Part I-Tier 1 Tools.

    Get PDF
    Tier 1 occupational exposure assessment tools recommended for use under the Registration, Evaluation, Authorization, and restriction of CHemicals (REACH) were evaluated using newly collected measurement data. Evaluated tools included the ECETOC TRAv2 and TRAv3, MEASEv1.02.01, and EMKG-EXPO-TOOL. Fifty-three exposure situations (ESs) based on tasks/chemicals were developed from National Institute for Occupational Safety and Health field surveys. During the field surveys, high quality contextual information required for evaluating the tools was also collected. For each ES, applicable tools were then used to generate exposure estimates using a consensus approach. Among 53 ESs, only those related to an exposure category of liquids with vapor pressure (VP) > 10 Pa had sufficient numbers of exposure measurements (42 ESs with n = 251 for TRAv2 and TRAv3 and 40 ESs with n = 243 for EMKG-EXPO-TOOL) to be considered in detail. The results for other exposure categories (aqueous solutions, liquids with VP ≤ 10 Pa, metal processing, powders, and solid objects) had insufficient measurement to allow detailed analyses (results listed in the Supplementary File). Overall, EMKG-EXPO-TOOL generated more conservative results than TRAv2 and TRAv3 for liquids with high VP. This finding is at least partly due to the fact that the EMKG-EXPO-TOOL only considers pure substances and not mixtures of chemical agents. For 34 out of 40 ESs available for chemicals with VP > 10 Pa, the liquid was a mixture rather than a pure substance. TRAv3 was less conservative than TRAv2, probably due to additional refinement of some input parameters. The percentages of exposure measurement results exceeding the corresponding tool estimates for liquids with VP > 10 Pa by process category and by input parameters were always higher for TRAv3 compared to those for TRAv2. Although the conclusions of this study are limited to liquids with VP > 10 Pa and few process categories, this study utilized the most transparent contextual information compared to previous studies, reducing uncertainty from assumptions for unknown input parameters. A further validation is recommended by collecting sufficient exposure data covering other exposure categories and all process categories under REACH

    Reusability of filtering facepiece respirators after decontamination through drying and germicidal UV irradiation.

    Get PDF
    During pandemics, such as the SARS-CoV-2, filtering facepiece respirators plays an essential role in protecting healthcare personnel. The recycling of respirators is possible in case of critical shortage, but it raises the question of the effectiveness of decontamination as well as the performance of the reused respirators. Disposable respirators were subjected to ultraviolet germicidal irradiation (UVGI) treatment at single or successive doses of 60 mJ/cm <sup>2</sup> after a short drying cycle (30 min, 70°C). The germicidal efficacy of this treatment was tested by spiking respirators with two staphylococcal bacteriophages (vB_HSa_2002 and P66 phages). The respirator performance was investigated by the following parameters: particle penetration (NaCl aerosol, 10-300 nm), scanning electron microscopy (SEM), Fourier-transform infrared spectroscopy (FTIR), differential scanning calorimetry and mechanical tensile tests. No viable phage particles were recovered from any of the respirators after decontamination (log reduction in virus titre >3), and no reduction in chemical or physical properties (SEM, particle penetrations <5%-6%) were observed. Increasing the UVGI dose 10-fold led to chemical alterations of the respirator filtration media (FTIR) but did not affect the physical properties (particle penetration), which was unaltered even at 3000 mJ/cm <sup>2</sup> (50 cycles). When respirators had been used by healthcare workers and undergone decontamination, they had particle penetration significantly greater than never donned respirators. This decontamination procedure is an attractive method for respirators in case of shortages during a SARS pandemic. A successful implementation requires a careful design and particle penetration performance control tests over the successive reuse cycles

    The role of water fittings in intensive care rooms as reservoirs for the colonization of patients with Pseudomonas aeruginosa

    Get PDF
    International audienceOBJECTIVE: To assess the role of the water environment in the Pseudomonas aeruginosa colonization of patients in intensive care units in the absence of a recognized outbreak. DESIGN AND SETTING: Prospective, single-centre study over an 8-week period in two adult ICUs at a university hospital. Environmental samples were taken from the water fittings of rooms once per week, during a 8-week period. Patients were screened weekly for P. aeruginosa carriage. Environmental and humans isolates were genotyped by using pulsed-field gel electrophoresis. RESULTS: P. aeruginosa was detected in 193 (86.2%) of the 224 U-bend samples and 10 of the 224 samples taken from the tap (4.5%). Seventeen of the 123 patients admitted were colonized with P. aeruginosa. Only one of the 14 patients we were able to evaluate was colonized by a clone present in the water environment of his room before the patient's first positive sample was obtained. CONCLUSION: The role of the water environment in the acquisition of P. aeruginosa by intensive care patients remains unclear, but water fittings seem to play a smaller role in non-epidemic situations than expected by many operational hospital hygiene teams
    corecore