183 research outputs found

    Study of a Nonlocal Density scheme for electronic--structure calculations

    Full text link
    An exchange-correlation energy functional beyond the local density approximation, based on the exchange-correlation kernel of the homogeneous electron gas and originally introduced by Kohn and Sham, is considered for electronic structure calculations of semiconductors and atoms. Calculations are carried out for diamond, silicon, silicon carbide and gallium arsenide. The lattice constants and gaps show a small improvement with respect to the LDA results. However, the corresponding corrections to the total energy of the isolated atoms are not large enough to yield a substantial improvement for the cohesive energy of solids, which remains hence overestimated as in the LDA.Comment: 4 postscript figure

    Improvement of psychometric properties of a scale measuring inpatient satisfaction with care: a better response rate and a reduction of the ceiling effect

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The objective was to solve two problems of an already validated scale measuring inpatient opinion on care: 1) a high non-response rate for some items due to the "not applicable" response option and 2) a skewed score distribution with high ceiling effect.</p> <p>Methods</p> <p>The EQS-H scale ("échelle de qualité des soins en hospitalisation") comprised 26 items and 2 sub-scales of 13 items each, 'quality of medical information' (MI) and 'relationships with staff and daily routine' (RS). Three studies were conducted: a first mono-centre study (n = 552, response rate = 83.4%, self-completion of the scale the day before discharge) to construct a shorter version of the scale without the items with high non-response rate and maintaining those useful to ensure good internal validity (construct, convergent and divergent) and reliability; a second mono-centre study (n = 1246, response rate = 77.9%, self-completion of the scale before discharge) to confirm psychometric properties of the new version; a third multi-centre national study (n = 886, response rate 41.7%, self-completion at home 15 days after discharge) to test a new response pattern in order to reduce ceiling effect.</p> <p>Results</p> <p>Six items having a non-response rate >20% were deleted, increasing rates of exhaustive response to all items from 15% to 48%. Factorial analysis supported the evidence for removing 4 more items to ensure good internal validity and reliability of the new version. These good results (initial variance explained: 43%; Cronbach's α: 0.80 (MI) and 0.81 (RS)) were confirmed by the second study. The new response format produced a normalisation of the 2 scores with a large decrease in ceiling effect (25% to 4% for MI subscale and 61% to 8% for RS). Psychometric properties of the final version were excellent: the 2 subscales (8 items each) explained 66% of the variance in principal component analysis, Cronbach's α were respectively 0.92 (MI) and 0.93 (RS).</p> <p>Conclusion</p> <p>The new version of the EQS-H has better psychometric properties than the previous one. Rates of missing values are lower, and score distribution is normalized. An English version of this scale focused on quality of medical information delivered and on relationship with staff already exists, and this could be useful to conduct cross-cultural studies of health care service quality.</p

    Human Cysteine Cathepsins Are Not Reliable Markers of Infection by Pseudomonas aeruginosa in Cystic Fibrosis

    Get PDF
    Cysteine cathepsins have emerged as new players in inflammatory lung disorders. Their activities are dramatically increased in the sputum of cystic fibrosis (CF) patients, suggesting that they are involved in the pathophysiology of CF. We have characterized the cathepsins in CF expectorations and evaluated their use as markers of colonization by Pseudomonas aeruginosa. The concentrations of active cathepsins B, H, K, L and S were the same in P. aeruginosa-positive (19 Ps+) and P. aeruginosa-negative (6 Ps−) samples, unlike those of human neutrophil elastase. Also the cathepsin inhibitory potential and the cathepsins/cathepsin inhibitors imbalance remained unchanged and similar (∌2-fold) in the Ps+ and Ps− groups (p<0.001), which correlated with the breakdown of their circulating cystatin-like inhibitors (kininogens). Procathepsins, which may be activated autocatalytically, are a potential proteolytic reservoir. Immunoblotting and active-site labeling identified the double-chain cathepsin B, the major cathepsin in CF sputum, as the main molecular form in both Ps+ and Ps− samples, despite the possible release of the ∌31 kDa single-chain form from procathepsin B by sputum elastase. Thus, the hydrolytic activity of cysteine cathepsins was not correlated with bacterial colonization, indicating that cathepsins, unlike human neutrophil elastase, are not suitable markers of P. aeruginosa infection

    Towards actionable international comparisons of health system performance: expert revision of the OECD framework and quality indicators

    Get PDF
    Objective To review and update the conceptual framework, indicator content and research priorities of the Organisation for Economic Cooperation and Development's (OECD) Health Care Quality Indicators (HCQI) project, after a decade of collaborative work. Design A structured assessment was carried out using a modified Delphi approach, followed by a consensus meeting, to assess the suite of HCQI for international comparisons, agree on revisions to the original framework and set priorities for research and development. Setting International group of countries participating to OECD projects. Participants Members of the OECD HCQI expert group. Results A reference matrix, based on a revised performance framework, was used to map and assess all seventy HCQI routinely calculated by the OECD expert group. A total of 21 indicators were agreed to be excluded, due to the following concerns: (i) relevance, (ii) international comparability, particularly where heterogeneous coding practices might induce bias, (iii) feasibility, when the number of countries able to report was limited and the added value did not justify sustained effort and (iv) actionability, for indicators that were unlikely to improve on the basis of targeted policy interventions. Conclusions The revised OECD framework for HCQI represents a new milestone of a long-standing international collaboration among a group of countries committed to building common ground for performance measurement. The expert group believes that the continuation of this work is paramount to provide decision makers with a validated toolbox to directly act on quality improvement strategie

    Impact of a hospital improvement initiative in Bangladesh on patient experiences and satisfaction with services: two cross-sectional studies

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The Bangladesh government implemented a pilot Hospital Improvement Initiative (HII) in five hospitals in Sylhet division between 1998 and 2003. This included management and behaviour change training for staff, waste disposal and procurement, and referral arrangements. Two linked cross-sectional surveys in 2000 and 2003 assessed the impact of the HII, assessing both patients' experience and satisfaction and public views and use of the hospitals.</p> <p>Methods</p> <p>In each survey we asked 300 consecutive outpatients and a stratified random sample of 300 inpatients in the five hospitals about waiting and consultation time, use of an agent for admission, and satisfaction with privacy, cleanliness, and staff behaviour. The field teams observed cleanliness and privacy arrangements, and visited a sample of households in communities near the hospitals to ask about their opinions and use of the hospital services. Analysis examined changes over time in patients' experience and views. Multivariate analysis took account of other variables potentially associated with the outcomes. Survey managers discussed the survey findings with gender stratified focus groups in each sample community.</p> <p>Results</p> <p>Compared with 2000, an outpatient in three of the hospitals in 2003 was more likely to be seen within 10 minutes and for at least five minutes by the doctor, but outpatients were less likely to report receiving all the prescribed medicines from the hospital. In 2003, inpatients were more likely to have secured admission without using an agent. Although patients’ satisfaction with several aspects of care improved, most changes were not statistically significant. Households in 2003 were significantly more likely to rate the hospitals as good than in 2000. Use of the hospitals did not change, except that more households used the medical college hospital for inpatient care in 2003. Focus groups confirmed criticisms of services and suggested improvements.</p> <p>Conclusion</p> <p>Improvements in some aspects of patients' experience may have been due to the programme, but the decreased availability of medicines in government facilities across the country over the period also occurred in these hospitals. Monitoring patients’ experience and satisfaction as well as public views and use of hospital services is feasible and useful for assessing service interventions.</p
    • 

    corecore