15 research outputs found

    Comparison of the ALPS and PHILOS plating systems in proximal humeral fracture fixation – a retrospective study

    No full text
    Abstract Background Open reduction and plate osteosynthesis are considered as a successful technique for the treatment of proximal humerus fracture (PHF) despite high complication rates. The objective of our study was to review the clinical outcome and complications of the Anatomic Locking Plate System (ALPS) and compare it to the Proximal Humeral Internal Locking System (PHILOS). Our hypothesis was that ranges of motion (ROM) were superior and complication rates were lower with ALPS. Methods Twenty patients treated with ALPS for PHF were retrospectively compared to 27 patients treated with PHILOS. Union, ROM and complications were clinically and radiologically assessed at 6 weeks, 3, 6, 12 and 18–24 months post-operatively. Results Mean age was 52 ± 14 in the ALPS group and 58 ± 13 in the PHILOS group. Last follow-ups were conducted at a mean of 20.6 ± 4.8 months. Mean shoulder abduction was superior with ALPS by 14° (p-value = 0.036), 15° (p-value = 0.049), and 15° (p-value = 0.049) at 3, 6, and 12 months respectively. Mean shoulder external rotation was superior with ALPS by 11° (p-value = 0.032), 15° (p-value = 0.010) and 12° (p-value = 0.016) at 6 weeks, 3 and 6 months respectively. At the end of the follow-up, ROM remained better with ALPS, but not significantly. Complication rates over 21 months reached 20% with ALPS and 48% with PHILOS (p-value = 0.045). Implant removal rates reached 10% with ALPS and 37% with PHILOS (p-value = 0.036). Avascular necrosis was the only cause for hardware removal in the ALPS group. Conclusion The ALPS group showed better clinical outcomes with faster recovery in abduction and external rotation, although no difference in ROM remained after 21 months. Additionally, the complications rate was lower at last follow up. In our experience, the ALPS plating system is an effective management option in some PHF

    Metaphyseal tibial level (MTL) screws: a modified percutaneous technique for lateral plateau depression fractures

    No full text
    Introduction: Lateral tibial plateau fractures are more frequent than medial fractures, and those with articular depression are particularly challenging because of high displacement risk. To prevent secondary subsidence, the gold standard is raft screws with a periarticular or anti-glide plate. Graft is used to fill the metaphyseal defect created by reduction in the depressed fragment. We present a case of Schatzker II fracture managed in a complete percutaneous fashion, with a new combined technique of raft screws and interference screw used as a support. Case report: A 51-year-old female sustained a Schatzker II tibial plateau fracture. Based on pre-operative CT, direction of reduction force to apply was drawn on coronal and sagittal cuts. Operative technique: Under fluoroscopic control, the split component of the fracture was reduced. The cortical window was then drilled in the lateral cortex, and a K wire advanced under the depressed fragment under fluoroscopic guidance. After fragment reduction with a bone impacter, internal fixation was completed by percutaneous introduction of two subchondral cortical screws. A bioabsorbable interference screw was then introduced in the impacter tunnel to support impacted bone under the reduced articular surface. Finally, a cortical screw was introduced, from anterior to posterior to prevent screw cut-out. Conclusion: The combination of subchondral screws in a jail technique with a bioabsorbable interference screw that we named metaphyseal tibia level (MTL) screw technique is, to our knowledge, not described. The MTL screw promises to be a true percutaneous reduction and fixation technique for Schatzker II and III fractures in patients with reasonable bone quality

    Total clavicle reconstruction with free peroneal graft for the surgical management of chronic nonbacterial osteomyelitis of the clavicle: a case report

    Get PDF
    Abstract Background Chronic nonbacterial osteomyelitis (CNO) is a rare chronic autoinflammatory syndrome affecting mainly children and young adults. The natural history of the disease is marked by recurrent pain as the mainstay of inflammatory outbreaks. Typical radiographic findings are osteosclerosis and hyperostosis of the medial clavicle, sternum and first rib. Compression of the brachial plexus is exceedingly rare and one of the few surgical indications. Literature on total clavicle reconstruction is scarce. While claviclectomy alone has been associated with fair functional and cosmetic outcomes, several reconstruction techniques with autograft, allograft or even cement (“Oklahoma prosthesis”) have been reported with the aim of achieving better pain control, cosmetic outcome and protecting the brachial plexus and subclavian vessels. We herewith report a unique case of complicated CNO of the clavicle treated with total clavicle reconstruction using a free peroneal graft. Case presentation A 21-year-old female patient presented with CNO of her left clavicle, associated with recurrent, progressive and debilitating pain as well as limited range of motion. In recent years, she started complaining of paresthesia, weakness and pain radiating to her left arm during arm abduction. The clavicle diameter reached 6 cm on computed tomography, with direct compression of the brachial plexus and subclavian vessels. Following surgical biopsy for diagnosis confirmation, she further developed a chronic cutaneous fistula. Therefore, a two-stage total clavicle reconstruction using a vascularized peroneal graft stabilized by ligamentous reconstruction was performed. At two-year follow-up, complete pain relief and improvement of her left shoulder Constant-Murley score were observed, along with satisfactory cosmetic outcome. Conclusions This case illustrates a rarely described complication of CNO with direct compression of the brachial plexus and subclavian vessels, and chronic cutaneous fistula. To our knowledge, there is no consensus regarding the optimal management of this rare condition in this context. Advantages and complications of clavicle reconstruction should be carefully discussed with patients due to limited evidence of superior clinical outcome and potential local and donor-site complications. While in our case the outcomes met the patient’s satisfaction, it remains an isolated case and further reports are awaited to help surgeons and patients in their decision process

    CoRoT opens a new era in hot B subdwarf asteroseismology. Detection of multiple g-mode oscillations in KPD 0629-0016

    Full text link
    Context. The asteroseismic exploitation of long period, g-mode hot B subdwarf (sdB) pulsators has been a long sought objective undermined, thus far, by the difficulty of obtaining sufficiently precise and continuous time series data from the ground. Aims: Fast photometry from space appears to be the only means of gathering the appropriate asteroseismic data for this type of star. We explore this possibility with the CoRoT (COnvection, ROtation, and planetary Transits) satellite. Methods: We obtained ~24 days of high quality, nearly continuous photometric data with CoRoT during a short run (SRa03) dedicated to the long period sdB pulsator KPD 0629-0016. We analysed the frequency (period) content of the CoRoT time series by combining Fourier analysis, nonlinear least squares fitting, and prewhitening techniques. Results: Our study has led to the detection of a large number of g-mode pulsations in KPD 0629-0016, with 17 frequencies clearly identified in addition to 7 possible (although more uncertain) peaks emerging above the mean noise level (estimated at ~57 ppm). This is more than is typically detected for sdB stars from the ground and, more importantly, the frequencies of all uncovered g-modes are, for the first time, reliably measured. This paves the way for a detailed asteroseismic analysis of this star. The oscillations are found in the 90-400 μHz frequency range with a dominant mode at 205.29 μHz (P = 1.353 h) of amplitude 0.246% of the mean brightness, i.e., typical of mid-radial order g-mode pulsations. Conclusions: These photometric observations of KPD 0629-0016 demonstrate that g-mode sdB pulsators have rich oscillation spectra that are accessible to current space-based facilities. CoRoT opens up a new era in asteroseismology of hot B subdwarf stars

    The smartphone inclinometer: A new tool to determine elbow range of motion?

    No full text
    There are easily accessible tools on smartphones (APP) for measuring elbow range of motion (ROM). The purpose of this study is to evaluate the validity of a particular APP in determining elbow ROM in comparison with the commonly used goniometer (GON), surgeon estimation of range (EST) and measurement on X-ray (XR). The study included 20 patients (40 elbows). Flexion, extension, pronation and supination were measured using three different methods: EST, GON and APP. Radiographic measurements were taken using the average humeral diaphysis axis and dorsal midthird of ulna in flexion and extension. The accuracy of the three different methods has been compared to GON using statistical analysis (ANOVA and paired samples test). There was no statistically significant difference for XR flexion measurement (mean of 2.8° ± 1.5°). The APP overestimated flexion (mean of 6.4° ± 1.0°), and EST underestimated it (mean of - 7.9° ± 1.1°). For extension, the mean difference was 2.8° ± 0.7° for EST and - 26.8° ± 3.1° for XR. The APP method did not significantly differ from GON. Supination accuracy was greater with EST (2.7° ± 1.7°) than with APP (5.9° ± 1.9°). There was no difference for pronation measurement with both EST and APP. This study is the first comparing four measurement techniques of elbow ROM. Our results showed that EST was only accurate for forearm rotation. The XR scored the best for flexion but is less reliable for extension. Surprisingly, compared to GON, APP did not correlate as we expected for flexion and supination, but the other methods were also inaccurate. We found APP to be very useful to measure complete arc of motion (difference between maximal flexion and maximal extension). III, Retrospective review of a prospective cohort of elbow fracture patients: Diagnostic Study
    corecore