144 research outputs found

    Horizontal push out tests on a steel-yielding demountable shear connector

    Full text link
    [EN] The most common type of a steel concrete composite beam is the one using conventional welded headed studs to connect the top flange of a steel beam to the concrete slab. However, the monolithic structure between the headed studs and the concrete slab prevents the deconstruction of the beam. More sustainable solutions in construction can be achieved by developing demountable connections which allow for fully deconstruction and reuse of all structural systems. This paper presents a novel demountable shear connector for use in steel concrete composite beams in conjunction with precast hollow core slab units. The demountable connection proposed has the advantages of minimal use of in situ concrete required only in specific regions, increased ductility due to the unique shape of the shear connector and since it is not embedded in in situ concrete, it facilitates the deconstruction procedure. Ten horizontal push out tests aiming at investigating the structural performance of the demountable shear connector were carried out. The strength of the connection is predicted using simple mechanics based on plastic beam analysis. The experimental results showed that the proposed demountable shear connector can achieve increased strength depending on the geometric characteristics of the connector, a ductile slip-load curve and a very high slip capacity.Feidaki, E.; Vasdravellis, G. (2018). Horizontal push out tests on a steel-yielding demountable shear connector. En Proceedings of the 12th International Conference on Advances in Steel-Concrete Composite Structures. ASCCS 2018. Editorial Universitat Politècnica de València. 221-228. https://doi.org/10.4995/ASCCS2018.2018.7073OCS22122

    Behaviour and design of composite beams subjected to negative bending and compression

    Get PDF
    This paper investigates the behaviour of steel–concrete composite beams subjected to the combined effects of negative bending and axial compression. Six full-scale tests were conducted on composite beams subjected to negative moment while compression was applied simultaneously. Following the tests, a nonlinear finite element model was developed and calibrated against the experimental results. The model was found to be capable of predicting the nonlinear response and the ultimate failure modes of the tested beams. The developed finite element model was further used to carry out a series of parametric analyses on a range of composite sections commonly used in practice. It was found that, when a compressive load acts in the composite section, the negative moment capacity of a composite beam is significantly reduced and local buckling in the steel beam is more pronounced, compromising the ductility of the section. Rigid plastic analysis based on sectional equilibrium can reasonably predict the combined strength of a composite section and, thus, can be used conservatively in the design practice. Based on the experimental outcomes and the finite element analyses a simplified design model is proposed for use in engineering practice

    3D numerical assessment of the progressive collapse resistance of a seismic-resistant steel building with post-tensioned beam-column connections

    Get PDF
    This paper presents the numerical assessment of the progressive collapse resistance of a seismic-resistant steel building with post-tensioned beam-column connections. The numerical simulations are carried out in 3D under a loss of column scenario. The 3D model considers the effect of the composite slab, where composite beams and their shear connectors are modeled with a combination of shell, beam and nonlinear connector elements. All the beam-column and beam-to-beam connections are modeled using nonlinear connector elements with appropriate failure criteria. Moreover, the steel frame for which a column is removed is modelled in full detail with the aid of 3D solid elements to accurately capture its local and global nonlinear behavior. Nonlinear static analyses are carried out to identify the failure modes of the building under a sudden loss of column scenario and investigate the effect of the floor slab on the overall progressive collapse resistance

    Probabilistic economic seismic loss estimation in steel buildings using post-tensioned moment-resisting frames and viscous dampers

    Get PDF
    The potential of post-tensioned self-centering moment-resisting frames (SC-MRFs) and viscous dampers to reduce the economic seismic losses in steel buildings is evaluated. The evaluation is based on a prototype steel building designed using four different seismicresistant frames: (a) conventional moment resisting frames (MRFs); (b) MRFs with viscous dampers; (c) SC-MRFs; or (d) SC-MRFs with viscous dampers. All frames are designed according to Eurocode 8, and have the same column/beam cross-sections and similar periods of vibration. Viscous dampers are designed to reduce the peak story drift under the design basis earthquake (DBE) from 1.8% to 1.2%. Losses are estimated by developing vulnerability functions according to the FEMA P-58 methodology, which considers uncertainties in earthquake ground motion, structural response, and repair costs. Both the probability of collapse and the probability of demolition due to excessive residual story drifts are taken into account. Incremental dynamic analyses are conducted using models capable to simulate all limit states up to collapse. A parametric study on the effect of the residual story drift threshold beyond which is less expensive to rebuild a structure than to repair is also conducted. It is shown that viscous dampers are more effective than post-tensioning for seismic intensities equal or lower than the maximum considered earthquake (MCE). Posttensioning is effective in reducing repair costs only for seismic intensities higher than the DBE. The paper also highlights the effectiveness of combining post-tensioning and supplemental viscous damping by showing that the SC-MRF with viscous dampers achieves significant repair cost reductions compared to the conventional MRF

    Self-centering steel column base with metallic energy dissipation devices

    Get PDF
    Column bases of seismic-resistant steel frames are typically designed as full-strength to ensure that plastic hinges develop in the bottom end of the first-storey columns. Alternatively, column bases may be designed as partial-strength and dissipate energy through inelastic deformations in their main components (i.e., base plate, steel anchor rods). Both design philosophies result in difficult-to-repair damage and residual drifts. Moreover, the second design philosophy results in complex hysteretic behaviour with strength and stiffness deterioration. This paper proposes a partial-strength low-damage self-centering steel column base. The column base provides flexibility in the design as its rotational stiffness and moment resistance can be independently tuned. The paper presents an analytical model that predicts the stiffness, strength, and hysteretic behaviour of the column base. In addition, a design procedure and detailed finite element models are presented. The paper evaluates the effectiveness of the column base by carrying out nonlinear dynamic analyses on a prototype steel building designed as post-tensioned self-centering moment-resisting frame. The results demonstrate the potential of the column base to reduce the residual first-storey drifts and protect the first-storey columns from yielding.</p

    Design and modeling of a novel damage-free steel column base

    Get PDF
    Column bases are fundamental components of a steel frame. However their design has not yet received appropriate attention. Conventional steel column bases cannot be easily repaired if damaged and exhibit difficult-to-predict and simulate stiffness, strength and hysteretic behaviour. This paper proposes a novel demountable and fully repairable column base for resilient steel buildings. The new column base isolates damage in easy-to-replace structural elements with the goal of minimizing repair time and disruption of the building service in the aftermath of a strong earthquake. Moreover, it can be easily constructed and deconstructed to enable sustainable steel frame designs. It provides significant flexibility in the design, with rotational stiffness and moment resistance that can be independently tuned. It has self-centering capability for reducing residual drifts. The paper presents design rules, an analytical hysteretic model and a 3D finite element model for the new column base

    Progressive collapse resistance of steel self-centering MRFs including the effects of the composite floor

    Get PDF
    This paper presents progressive collapse simulations to assess the robustness of a seismic-resistant building using self-centering moment resisting frames (SC-MRFs) under a sudden column loss scenario. The first floor of the building, including the composite floor, was modelled in ABAQUS using a mixture of finite element types and simulation methods to balance computational cost and accuracy. First, key components of the numerical model, including the composite beams, the fin-plate beam-column connections, and the perimeter SC-MRFs, were validated against available experimental results to ensure a reliable simulation. The validated model was then used to study the robustness of the building under a sudden column loss event. Both nonlinear static and dynamic analyses were employed. The simulations allowed for the identification of all possible failure modes and the quantification of the contribution of the composite floor to the robustness of the frame. The results show that the building can withstand the code-prescribed load with a safety factor of 2 and that the structural limit state that triggers progressive collapse is the buckling of the gravity columns. The Dynamic Increase Factor (DIF) was also identified by comparing the static and dynamic responses

    Ultralow Cycle Fatigue Tests and Fracture Prediction Models for Duplex Stainless-Steel Devices of High Seismic Performance Braced Frames

    Get PDF
    This paper presents ultralow cycle fatigue tests and the calibration of different fracture models for duplex stainless-steel devices of high seismic performance braced frames. Two different geometries of the devices were tested in full scale under 14 cyclic loading protocols up to fracture. The imposed protocols consisted of standard, constant-amplitude, and randomly generated loading histories. The test results show that the devices have stable hysteresis, high postyield stiffness, and large energy-dissipation and fracture capacities. Following the tests, two micromechanics-based models, i.e., the cyclic void growth model and the built-in ABAQUS ductile fracture model, were calibrated using monotonic and cyclic tests on circumferentially notched coupons and complementary finite-element simulations. In addition, Coffin-Manson-like relationships were fitted to the results of the constant-amplitude tests of the devices, and the Palmgren-Miner’s rule was used to predict fracture of the devices under the randomly generated loading protocols. Comparisons of the experimental and numerical results show that the calibrated models can predict ductile fracture of the devices due to ultralow cycle fatigue with acceptable accuracy
    corecore