23 research outputs found

    A Patient-Specific Foot Model for the Estimate of Ankle Joint Forces in Patients with Juvenile Idiopathic Arthritis

    Get PDF
    Juvenile idiopathic arthritis (JIA) is the leading cause of childhood disability from a musculoskeletal disorder. It generally affects large joints such as the knee and the ankle, often causing structural damage. Different factors contribute to the damage onset, including altered joint loading and other mechanical factors, associated with pain and inflammation. The prediction of patients' joint loading can hence be a valuable tool in understanding the disease mechanisms involved in structural damage progression. A number of lower-limb musculoskeletal models have been proposed to analyse the hip and knee joints, but juvenile models of the foot are still lacking. This paper presents a modelling pipeline that allows the creation of juvenile patient-specific models starting from lower limb kinematics and foot and ankle MRI data. This pipeline has been applied to data from three children with JIA and the importance of patient-specific parameters and modelling assumptions has been tested in a sensitivity analysis focused on the variation of the joint reaction forces. This analysis highlighted the criticality of patient-specific definition of the ankle joint axes and location of the Achilles tendon insertions. Patient-specific detection of the Tibialis Anterior, Tibialis Posterior, and Peroneus Longus origins and insertions were also shown to be important

    3D Muscle modelling from CT-Scan

    No full text
    info:eu-repo/semantics/publishe

    Registration of 6-DOFs Electrogoniometry and CT Medical Imaging for 3D Joint Modeling

    No full text
    The paper describes a method in which two data-collecting systems, medical imaging and electrogoniometry, are combined to allow the accurate and simultaneous modeling of both the spatial kinematics and the morphological surface of a particular joint. The joint of interest (JOI) is attached to a Plexiglas jig that includes four metallic markers defining a local reference system (RGONIO) for the kinematics data. Volumetric data of the JOI and the RGONIO markers are collected from medical imaging. The spatial location and orientation of the markers in the global reference system (RCT) of the medical-imaging environment are obtained by applying object-recognition and classification methods on the image dataset. Segmentation and 3D isosurfacing of the JOI are performed to produce a 3D model including two anatomical objects - the proximal and distal JOI segments. After imaging, one end of a custom-made 3D electrogoniometer is attached to the distal segment of the JOI, and the other end is placed at the RGONIO origin; the JOI is displaced and the spatial kinematics data is recorded by the goniometer. After recording, data registration from RGONIO to RCT occurred prior to simulation. Data analysis was performed using both joint coordinate system (JCS) and instantaneous helical axis (IHA). Finally, the 3D joint model is simulated in real time using the experimental kinematics data. The system is integrated into a computer graphics interface, allowing free manipulation of the 3D scene. The overall accuracy of the method has been validated with two other kinematics data collection methods including a 3D digitizer and interpolation of the kinematics data from discrete positions obtained from medical imaging. Validation has been performed on both superior and inferior radio-ulna joints (i.e. prono-supination motion). Maximal RMS error was 1° and 1.2mm on the helical axis rotation and translation, respectively. Prono-supination of the forearm showed a total rotation of 132° for 0.8mm of translation. The method reproducibility using JCS parameters was in average 1° (maximal deviation=2°) for rotation, and 1mm (maximal deviation=2mm) for translation. In vitro experiments have been performed on both knee joint and ankle joint. Averaged JCS parameters for the knee were 109°, 17° and 4° for flexion, internal rotation and abduction, respectively. Averaged maximal translation values for the knee were 12, 3 and 4mm posteriorly, medially and proximally, respectively. Averaged JCS parameters for the ankle were 43°, 9° and 3° for plantarflexion, adduction and internal rotation, respectively. Averaged maximal translation values for the ankle were 4, 2 and 1mm anteriorly, medially and proximally, respectively. © 2002 Elsevier Science Ltd. All rights reserved.IF: 1.536, IFmax: 1.536 (Journal of Biomechanics)info:eu-repo/semantics/publishe
    corecore