863 research outputs found

    Formation of convective cells in the scrape-off layer of the CASTOR tokamak

    Get PDF
    Understanding of the scrape-off layer (SOL) physics in tokamaks requires diagnostics with sufficient temporal and spatial resolution. This contribution describes results of experiments performed in the SOL of the CASTOR tokamak (R=40 cm, a = 6 cm) by means of a ring of 124 Langmuir probes surrounding the whole poloidal cross section. The individual probes measure either the ion saturation current of the floating potential with the spatial resolution up to 3 mm. Experiments are performed in a particular magnetic configuration, characterized by a long parallel connection length in the SOL, L_par ~q2piR. We report on measurements in discharges, where the edge electric field is modified by inserting a biased electrode into the edge plasma. In particular, a complex picture is observed, if the biased electrode is located inside the SOL. The poloidal distribution of the floating potential appears to be strongly non-uniform at biasing. The peaks of potential are observed at particular poloidal angles. This is interpreted as formation of a biased flux tube, which emanates from the electrode along the magnetic field lines and snakes q times around the torus. The resulting electric field in the SOL is 2-dimensional, having the radial as well as the poloidal component. It is demonstrated that the poloidal electric field E_pol convects the edge plasma radially due to the E_pol x B_T drift either inward or outward depending on its sign. The convective particle flux is by two orders of magnitude larger than the fluctuation-induced one and consequently dominates.Comment: 12th International Congress on Plasma Physics, 25-29 October 2004, Nice (France

    Ion cyclotron wall conditioning experiments on Tore Supra in presence of the toroidal magnetic field

    Get PDF
    Wall conditioning techniques applicable in the presence of the high toroidal magnetic field will be required for the operation of ITER for tritium removal, isotopic ratio control and recovery to normal operation after disruptions. Recently ion cyclotron wall conditioning (ICWC) experiments have been carried out on Tore Supra in order to assess the efficiency of this technique in ITER relevant conditions. The ICRF discharges were operated in He/H-2 Mixtures at the Tore Supra nominal field (3.8 T) and a RF frequency of 48 MHz, i.e. within the ITER operational space. RF pulses of 60 s (max.) were applied using a standard Tore Supra two-strap resonant double loop antenna in ICWC mode, operated either in pi or 0-phasing with a noticeable improvement of the RF coupling in the latter case. In order to assess the efficiency of the technique for the control of isotopic ratio the wall was first preloaded using a D-2 glow discharge. After 15 minutes of ICWC in He/H-2 gas mixtures the isotopic ratio was altered from 4% to 50% at the price of an important H implantation into the walls. An overall analysis comparing plasma production and the conditioning efficiency as a function of discharge parameters is given

    Error estimates for solid-state density-functional theory predictions: an overview by means of the ground-state elemental crystals

    Get PDF
    Predictions of observable properties by density-functional theory calculations (DFT) are used increasingly often in experimental condensed-matter physics and materials engineering as data. These predictions are used to analyze recent measurements, or to plan future experiments. Increasingly more experimental scientists in these fields therefore face the natural question: what is the expected error for such an ab initio prediction? Information and experience about this question is scattered over two decades of literature. The present review aims to summarize and quantify this implicit knowledge. This leads to a practical protocol that allows any scientist - experimental or theoretical - to determine justifiable error estimates for many basic property predictions, without having to perform additional DFT calculations. A central role is played by a large and diverse test set of crystalline solids, containing all ground-state elemental crystals (except most lanthanides). For several properties of each crystal, the difference between DFT results and experimental values is assessed. We discuss trends in these deviations and review explanations suggested in the literature. A prerequisite for such an error analysis is that different implementations of the same first-principles formalism provide the same predictions. Therefore, the reproducibility of predictions across several mainstream methods and codes is discussed too. A quality factor Delta expresses the spread in predictions from two distinct DFT implementations by a single number. To compare the PAW method to the highly accurate APW+lo approach, a code assessment of VASP and GPAW with respect to WIEN2k yields Delta values of 1.9 and 3.3 meV/atom, respectively. These differences are an order of magnitude smaller than the typical difference with experiment, and therefore predictions by APW+lo and PAW are for practical purposes identical.Comment: 27 pages, 20 figures, supplementary material available (v5 contains updated supplementary material
    corecore